Abstract: An important step in three-dimensional reconstruction
and computer vision is camera calibration, whose objective is to
estimate the intrinsic and extrinsic parameters of each camera. In this
paper, two linear methods based on the different planes are given. In
both methods, the general plane is used to replace the calibration
object with very good precision. In the first method, after controlling
the camera to undergo five times- translation movements and taking
pictures of the orthogonal planes, a set of linear constraints of the
camera intrinsic parameters is then derived by means of homography
matrix. The second method is to get all camera parameters by taking
only one picture of a given radius circle. experiments on simulated
data and real images,indicate that our method is reasonable and is a
good supplement to camera calibration.
Abstract: In this paper an algorithm for fast wavelength calibration of Optical Spectrum Analyzers (OSAs) using low power reference gas spectra is proposed. In existing OSAs a reference spectrum with low noise for precise detection of the reference extreme values is needed. To generate this spectrum costly hardware with high optical power is necessary. With this new wavelength calibration algorithm it is possible to use a noisy reference spectrum and therefore hardware costs can be cut. With this algorithm the reference spectrum is filtered and the key information is extracted by segmenting and finding the local minima and maxima. Afterwards slope and offset of a linear correction function for best matching the measured and theoretical spectra are found by correlating the measured with the stored minima. With this algorithm a reliable wavelength referencing of an OSA can be implemented on a microcontroller with a calculation time of less than one second.
Abstract: Simultaneous determination of multicomponents of phenol, resorcinol and catechol with a chemometric technique a PCranking artificial neural network (PCranking-ANN) algorithm is reported in this study. Based on the data correlation coefficient method, 3 representative PCs are selected from the scores of original UV spectral data (35 PCs) as the original input patterns for ANN to build a neural network model. The results obtained by iterating 8000 .The RMSEP for phenol, resorcinol and catechol with PCranking- ANN were 0.6680, 0.0766 and 0.1033, respectively. Calibration matrices were 0.50-21.0, 0.50-15.1 and 0.50-20.0 μg ml-1 for phenol, resorcinol and catechol, respectively. The proposed method was successfully applied for the determination of phenol, resorcinol and catechol in synthetic and water samples.
Abstract: With advances in computer vision, non-contact gaze tracking systems are heading towards being much easier to operate and more comfortable for use, the technique proposed in this paper is specially designed for achieving these goals. For the convenience in operation, the proposal aims at the system with simple configuration which is composed of a fixed wide angle camera and dual infrared illuminators. Then in order to enhance the usability of the system based on single camera, a self-adjusting method which is called Real-time gaze Tracking Algorithm with head movement Compensation (RTAC) is developed for estimating the gaze direction under natural head movement and simplifying the calibration procedure at the same time. According to the actual evaluations, the average accuracy of about 1° is achieved over a field of 20×15×15 cm3.
Abstract: Quality control is the crucial step for ISO 9001
Quality System Management Standard for companies. While
measuring the quality level of both raw material and semi
product/product, the calibration of the measuring device is an
essential requirement. Calibration suppliers are in the service sector
and therefore the calibration supplier selection is becoming a worthy
topic for improving service quality.
This study presents the results of a questionnaire about the
selection criteria of a calibration supplier. The questionnaire was
applied to 103 companies and the results are discussed in this paper.
The analysis was made with MINITAB 14.0 statistical programs.
“Competence of documentations" and “technical capability" are
defined as the prerequisites because of the ISO/IEC17025:2005
standard. Also “warranties and complaint policy", “communication",
“service features", “quality" and “performance history" are defined as
very important criteria for calibration supplier selection.
Abstract: A new hybrid method to realise high-precision
distortion determination for optical ultra-precision 3D measurement
systems based on stereo cameras using active light projection is
introduced. It consists of two phases: the basic distortion
determination and the refinement. The refinement phase of the
procedure uses a plane surface and projected fringe patterns as
calibration tools to determine simultaneously the distortion of both
cameras within an iterative procedure. The new technique may be
performed in the state of the device “ready for measurement" which
avoids errors by a later adjustment. A considerable reduction of
distortion errors is achieved and leads to considerable improvements
of the accuracy of 3D measurements, especially in the precise
measurement of smooth surfaces.
Abstract: In automotive systems almost all steps concerning the
calibration of several control systems, e.g., low idle governor or
boost pressure governor, are made with the vehicle because the timeto-
production and cost requirements on the projects do not allow for
the vehicle analysis necessary to build reliable models. Here is
presented a procedure using parametric and NN (neural network)
models that enables the generation of vehicle system models based
on normal ECU engine control unit) vehicle measurements. These
models are locally valid and permit pre and follow-up calibrations so
that, only the final calibrations have to be done with the vehicle.
Abstract: KSLV-I(Korea Space Launch Vehicle-I) is designed as
a launch vehicle to enter a 100 kg-class satellite to the LEO(Low Earth
Orbit). Attitude angles of the upper-stage, including roll, pitch and
yaw are controlled by the cold gas thruster system using nitrogen gas.
The cold gas thruster is an actuator in the RCS(Reaction Control
System). To design an attitude controller for the upper-stage, thrust
measurement in vacuum condition is required. In this paper, the new
thrust measurement system and calibration mechanism are developed
and measurement errors and signal processing method are presented.
Abstract: Repeated observation of a given area over time yields
potential for many forms of change detection analysis. These
repeated observations are confounded in terms of radiometric
consistency due to changes in sensor calibration over time,
differences in illumination, observation angles and variation in
atmospheric effects.
This paper demonstrates applicability of an empirical relative
radiometric normalization method to a set of multitemporal cloudy
images acquired by Resourcesat1 LISS III sensor. Objective of this
study is to detect and remove cloud cover and normalize an image
radiometrically. Cloud detection is achieved by using Average
Brightness Threshold (ABT) algorithm. The detected cloud is
removed and replaced with data from another images of the same
area. After cloud removal, the proposed normalization method is
applied to reduce the radiometric influence caused by non surface
factors. This process identifies landscape elements whose reflectance
values are nearly constant over time, i.e. the subset of non-changing
pixels are identified using frequency based correlation technique. The
quality of radiometric normalization is statistically assessed by R2
value and mean square error (MSE) between each pair of analogous
band.
Abstract: A camera in the building site is exposed to different
weather conditions. Differences between images of the same scene
captured with the same camera arise also due to temperature variations.
The influence of temperature changes on camera parameters
were modelled and integrated into existing analytical camera model.
Modified camera model enables quantitatively assessing the influence
of temperature variations.
Abstract: Calibration estimation is a method of adjusting the
original design weights to improve the survey estimates by using
auxiliary information such as the known population total (or mean)
of the auxiliary variables. A calibration estimator uses calibrated
weights that are determined to minimize a given distance measure to
the original design weights while satisfying a set of constraints
related to the auxiliary information. In this paper, we propose a new
multivariate calibration estimator for the population mean in the
stratified sampling design, which incorporates information available
for more than one auxiliary variable. The problem of determining the
optimum calibrated weights is formulated as a Mathematical
Programming Problem (MPP) that is solved using the Lagrange
multiplier technique.
Abstract: The paper depicts air velocity values, reproduced by laser Doppler anemometer (LDA) and ultrasonic anemometer (UA), relations with calculated ones from flow rate measurements using the gas meter which calibration uncertainty is ± (0.15 – 0.30) %. Investigation had been performed in channel installed in aerodynamical facility used as a part of national standard of air velocity. Relations defined in a research let us confirm the LDA and UA for air velocity reproduction to be the most advantageous measures. The results affirm ultrasonic anemometer to be reliable and favourable instrument for measurement of mean velocity or control of velocity stability in the velocity range of 0.05 m/s – 10 (15) m/s when the LDA used. The main aim of this research is to investigate low velocity regularities, starting from 0.05 m/s, including region of turbulent, laminar and transitional air flows. Theoretical and experimental results and brief analysis of it are given in the paper. Maximum and mean velocity relations for transitional air flow having unique distribution are represented. Transitional flow having distinctive and different from laminar and turbulent flow characteristics experimentally have not yet been analysed.
Abstract: Real-time hand tracking is a challenging task in many
computer vision applications such as gesture recognition. This paper
proposes a robust method for hand tracking in a complex environment
using Mean-shift analysis and Kalman filter in conjunction with 3D
depth map. The depth information solve the overlapping problem
between hands and face, which is obtained by passive stereo measuring
based on cross correlation and the known calibration data of
the cameras. Mean-shift analysis uses the gradient of Bhattacharyya
coefficient as a similarity function to derive the candidate of the hand
that is most similar to a given hand target model. And then, Kalman
filter is used to estimate the position of the hand target. The results
of hand tracking, tested on various video sequences, are robust to
changes in shape as well as partial occlusion.
Abstract: This paper presents an new vision technique for
robotic manipulation of randomly oriented objects in industrial
applications. The proposed approach uses 2D and 3D vision for
efficiently extracting the 3D pose of an object in the presence of
multiple randomly positioned objects. 2D vision permits to quickly
select the objects of interest for 3D processing with a new modified
ICP algorithm (FaR-ICP), thus reducing significantly the processing
time. The extracted 3D pose is then sent to the robot manipulator for
picking. The tests show that the proposed system achieves high
performances
Abstract: In this paper, we propose the robust water level detection method based on the accumulated histogram under small changed image which is acquired from water level surveillance camera. In general surveillance system, this is detecting and recognizing invasion from searching area which is in big change on the sequential images. However, in case of a water level detection system, these general surveillance techniques are not suitable due to small change on the water surface. Therefore the algorithm introduces the accumulated histogram which is emphasizing change of water surface in sequential images. Accumulated histogram is based on the current image frame. The histogram is cumulating differences between previous images and current image. But, these differences are also appeared in the land region. The band pass filter is able to remove noises in the accumulated histogram Finally, this algorithm clearly separates water and land regions. After these works, the algorithm converts from the water level value on the image space to the real water level on the real space using calibration table. The detected water level is sent to the host computer with current image. To evaluate the proposed algorithm, we use test images from various situations.
Abstract: This paper presents a generalized form of the
mechanistic deconvolution technique (GMD) to modeling image sensors applicable in various pan–tilt planes of view. The mechanistic deconvolution technique (UMD) is modified with the
given angles of a pan–tilt plane of view to formulate constraint parameters and characterize distortion effects, and thereby, determine
the corrected image data. This, as a result, does not require experimental setup or calibration. Due to the mechanistic nature of
the sensor model, the necessity for the sensor image plane to be
orthogonal to its z-axis is eliminated, and it reduces the dependency on image data. An experiment was constructed to evaluate the
accuracy of a model created by GMD and its insensitivity to changes in sensor properties and in pan and tilt angles. This was compared
with a pre-calibrated model and a model created by UMD using two sensors with different specifications. It achieved similar accuracy
with one-seventh the number of iterations and attained lower mean error by a factor of 2.4 when compared to the pre-calibrated and
UMD model respectively. The model has also shown itself to be robust and, in comparison to pre-calibrated and UMD model, improved the accuracy significantly.
Abstract: The purpose of this research is to develop and apply the
RSCMAC to enhance the dynamic accuracy of Global Positioning
System (GPS). GPS devices provide services of accurate positioning,
speed detection and highly precise time standard for over 98% area on
the earth. The overall operation of Global Positioning System includes
24 GPS satellites in space; signal transmission that includes 2
frequency carrier waves (Link 1 and Link 2) and 2 sets random
telegraphic codes (C/A code and P code), on-earth monitoring stations
or client GPS receivers. Only 4 satellites utilization, the client position
and its elevation can be detected rapidly. The more receivable
satellites, the more accurate position can be decoded. Currently, the
standard positioning accuracy of the simplified GPS receiver is greatly
increased, but due to affected by the error of satellite clock, the
troposphere delay and the ionosphere delay, current measurement
accuracy is in the level of 5~15m. In increasing the dynamic GPS
positioning accuracy, most researchers mainly use inertial navigation
system (INS) and installation of other sensors or maps for the
assistance. This research utilizes the RSCMAC advantages of fast
learning, learning convergence assurance, solving capability of
time-related dynamic system problems with the static positioning
calibration structure to improve and increase the GPS dynamic
accuracy. The increasing of GPS dynamic positioning accuracy can be
achieved by using RSCMAC system with GPS receivers collecting
dynamic error data for the error prediction and follows by using the
predicted error to correct the GPS dynamic positioning data. The
ultimate purpose of this research is to improve the dynamic positioning
error of cheap GPS receivers and the economic benefits will be
enhanced while the accuracy is increased.
Abstract: This work relates the development of an optical fiber
(OF) sensor for the detection and quantification of single walled
carbon nanotubes in aqueous solutions. The developed OF displays a
compact design, it requires less expensive materials and equipment
as well as low volume of sample (0.2 mL). This methodology was
also validated by the comparison of its analytical performance with
that of a standard methodology based on ultraviolet-visible
spectroscopy. The developed OF sensor follows the general SDS
calibration proposed for OF sensors as a more suitable calibration
fitting compared with classical calibrations.
Abstract: The main aim of this paper is to develop and calibrate
an econometric model for modeling prices of long term electricity
futures contracts. The calibration of our model is performed on data
from EEX AG allowing us to capture the specific features of German
electricity market. The data sample contains several structural breaks
which have to be taken into account for modeling. We model the data
with an ARIMAX model which reveals high correlation between the
price of electricity futures contracts and prices of LT futures
contracts of fuels (namely coal, natural gas and crude oil). Besides
this, also a share price index of representative electricity companies
traded on Xetra, spread between 10Y and 1Y German bonds and
exchange rate between EUR and USD appeared to have significant
explanatory power over these futures contracts on EEX.
Abstract: Infrared focal plane arrays (IRFPA) sensors, due to
their high sensitivity, high frame frequency and simple structure, have
become the most prominently used detectors in military applications.
However, they suffer from a common problem called the fixed pattern
noise (FPN), which severely degrades image quality and limits the
infrared imaging applications. Therefore, it is necessary to perform
non-uniformity correction (NUC) on IR image. The algorithms of
non-uniformity correction are classified into two main categories, the
calibration-based and scene-based algorithms. There exist some
shortcomings in both algorithms, hence a novel non-uniformity
correction algorithm based on non-linear fit is proposed, which
combines the advantages of the two algorithms. Experimental results
show that the proposed algorithm acquires a good effect of NUC with
a lower non-uniformity ratio.