Abstract: The material properties of OFHC copper film was investigated with the High-Speed Material Micro Testing Machine (HSMMTM) at the high strain rates. The rate-dependent stress-strain curves from the experiment and the Johnson−Cook curve fitting showed large discrepancies as the plastic strain increases since the constitutive model implies no rate-dependent strain hardening effect. A new constitutive model was proposed in consideration of rate-dependent strain hardening effect. The strain rate hardening term in the new constitutive model consists of the strain rate sensitivity coefficients of the yield strength and strain hardening.
Abstract: The aim of this paper is to confirm the effect of key
design parameters, the punch radius and punch angle, on rupture of the
expansion tube using a finite element analysis with a ductile damage
model. The results of the finite element analysis indicated that the
expansion ratio of the tube was mainly affected by the radius of the
punch. However, the rupture was more affected by the punch angle
than the radius of the punch. The existence of a specific punch angle,
at which rupture did not occur, even if the radius of the punch was
increased, was found.
Abstract: An important step in three-dimensional reconstruction
and computer vision is camera calibration, whose objective is to
estimate the intrinsic and extrinsic parameters of each camera. In this
paper, two linear methods based on the different planes are given. In
both methods, the general plane is used to replace the calibration
object with very good precision. In the first method, after controlling
the camera to undergo five times- translation movements and taking
pictures of the orthogonal planes, a set of linear constraints of the
camera intrinsic parameters is then derived by means of homography
matrix. The second method is to get all camera parameters by taking
only one picture of a given radius circle. experiments on simulated
data and real images,indicate that our method is reasonable and is a
good supplement to camera calibration.
Abstract: Microbubbbles incorporating ultrasound have been used to increase the efficacy of targeted drug delivery, because microstreaming induced by cavitating bubbles affects the drug perfusion into the target cells and tissues. In order to clarify the physical effects of microstreaming on drug perfusion into tissues, a preliminary experimental study of perfusion enhancement by a stably oscillating microbubble was performed. Microstreaming was induced by an oscillating bubble at 15 kHz, and perfusion of dye into an agar phantom was optically measured by histology on agar phantom. Surface color intensity and the penetration length of dye in the agar phantom were increased more than 70% and 30%, respectively, due to the microstreaming induced by an oscillating bubble. The mass of dye perfused into a tissue phantom for 30 s was increased about 80% in the phantom with an oscillating bubble. This preliminary experiment shows the physical effects of steady streaming by an oscillating bubble can enhance the drug perfusion into the tissues while minimizing the biological effects.