Abstract: The technology of mobile telephony has positively enhanced human life and reports on the bio safety of the radiation from their antennae have been contradictory, leading to serious litigations and violent protests by residents in several parts of the world. The crave for more information, as requested by WHO in order to resolve this issue, formed the basis for this study on the effect of the radiation from 900 MHz GSM antenna on the DNA of Hibiscus sabdariffa. Seeds of H. sabdariffa were raised in pots placed in three replicates at 100, 200, 300 and 400 metres from the GSM antennae in three selected test locations and a control where there was no GSM signal. Temperature (˚C) and the relative humidity (%) of study sites were measured for the period of study (24 weeks). Fresh young leaves were harvested from each plant at two, eight and twenty-four weeks after sowing and the DNA extracts were subjected to RAPD-PCR analyses. There were no significant differences between the weather conditions (temperature and relative humidity) in all the study locations. However, significant differences were observed in the intensities of radiations between the control (less than 0.02 V/m) and the test (0.40-1.01 V/m) locations. Data obtained showed that DNA of samples exposed to rays from GSM antenna had various levels of distortions, estimated at 91.67%. Distortions occurred in 58.33% of the samples between 2-8 weeks of exposure while 33.33% of the samples were distorted between 8-24 weeks exposure. Approximately 8.33% of the samples did not show distortions in DNA while 33.33% of the samples had their DNA damaged twice, both at 8 and at 24 weeks of exposure. The study showed that radiation from the 900 MHz GSM antenna is potent enough to cause distortions to DNA of H. sabdariffa even within 2-8 weeks of exposure. DNA damage was also independent of the distance from the antenna. These observations would qualify emissions from GSM mast as environmental hazard to the existence of plant biodiversities and all life forms in general. These results will trigger efforts to prevent further erosion of plant genetic resources which have been threatening food security and also the risks posed to living organisms, thereby making our environment very safe for our existence while we still continue to enjoy the benefits of the GSM technology.
Abstract: To evaluate the vigor of wheat seeds and stress of
premature aging effects on germination percentage, root length and
shoot length of five wheat cultivars that include Vynak, Karkheh,
Chamran, Star and Kavir which underwent a period of zero, two,
three, four days in terms of premature aging with 41°C temperature
and 100% relative humidity. Seed germination percentage, root
length and shoot length in these conditions were measured. This
experiment was conducted as a factorial completely randomized
design with four replications in laboratory conditions. The results
showed that each of aging treatments used in this experiment can be
used to detect differences in vigor of wheat varieties. Wheat cultivars
illustrated significant differences in germination percentage, root
length and shoot length in terms of premature aging. The wheat
cultivars; Astar and Vynak had maximum germination percentage
and Karkheh, respectively Kavir and Chamran had lowest percentage
of seed germination. Reactions of root and shoot length of wheat
cultivars was also different. The results showed that the seeds with a
stronger vigor affected less in premature aging condition and the
difference between the percentage of seed germination under normal
conditions and stress was significant and the seeds with the weaker
vigor were more sensitive to the premature aging stress and the
premature aging had more severe negative impact on seed vigor.
Abstract: This study addresses a concept of the Sustainable Building Environmental Model (SBEM) developed to optimize energy consumption in air conditioning and ventilation (ACV) systems without any deterioration of indoor environmental quality (IEQ). The SBEM incorporates two main components: an adaptive comfort temperature control module (ACT) and a new carbon dioxide demand control module (nDCV). These two modules take an innovative approach to maintain satisfaction of the Indoor Environmental Quality (IEQ) with optimum energy consumption; they provide a rational basis of effective control. A total of 2133 sets of measurement data of indoor air temperature (Ta), relative humidity (Rh) and carbon dioxide concentration (CO2) were conducted in some Hong Kong offices to investigate the potential of integrating the SBEM. A simulation was used to evaluate the dynamic performance of the energy and air conditioning system with the integration of the SBEM in an air-conditioned building. It allows us make a clear picture of the control strategies and performed any pre-tuned of controllers before utilized in real systems. With the integration of SBEM, it was able to save up to 12.3% in simulation of overall electricity consumption, and maintain the average carbon dioxide concentration within 1000ppm and occupant dissatisfaction in 20%.
Abstract: The effect of the inclusion of thyme and rosemary
essential oils into chitosan films, as well as the microbiological and
physical properties when storing chitosan film with and without the
mentioned inclusion was studied. The film forming solution was
prepared by dissolving chitosan (2%, w/v), polysorbate 80 (4% w/w
CH) and glycerol (16% w/w CH) in aqueous lactic acid solutions
(control). The thyme (TEO) and rosemary (REO) essential oils (EOs)
were included 1:1 w/w (EOs:CH) on their combination 50/50
(TEO:REO). The films were stored at temperatures of 5, 20, 33°C
and a relative humidity of 75% during four weeks. The films with
essential oil inclusion did not show an antimicrobial activity against
strains. This behavior could be explained because the chitosan only
inhibits the growth of microorganisms in direct contact with the
active sites. However, the inhibition capacity of TEO was higher than
the REO and a synergic effect between TEO:REO was found for S.
enteritidis strains in the chitosan solution.
Some physical properties were modified by the inclusion of
essential oils. The addition of essential oils does not affect the
mechanical properties (tensile strength, elongation at break, puncture
deformation), the water solubility, the swelling index nor the DSC
behavior. However, the essential oil inclusion can significantly
decrease the thickness, the moisture content, and the L* value of
films whereas the b* value increased due to molecular interactions
between the polymeric matrix, the loosing of the structure, and the
chemical modifications. On the other hand, the temperature and time
of storage changed some physical properties on the chitosan films.
This could have occurred because of chemical changes, such as
swelling in the presence of high humidity air and the reacetylation of
amino groups. In the majority of cases, properties such as moisture
content, tensile strength, elongation at break, puncture deformation,
a*, b*, chrome, 7E increased whereas water resistance, swelling
index, L*, and hue angle decreased.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: Energy consumption and users’ satisfaction were
compared in three LEED certified office buildings in turkey and an
office building in Egypt. The field studies were conducted in summer
2012. The measured environmental parameters in the four buildings
were indoor air temperature, relative humidity, CO2 percentage and
light intensity. The traditional building is located in Smart Village in
Abu Rawash, Cairo, Egypt. The building was studied for 7 days
resulting in 84 responds. The three rated buildings are in Istanbul;
Turkey. A Platinum LEED certified office building is owned by
BASF and gained a platinum certificate for new construction and
major renovation. The building was studied for 3 days resulting in 13
responds. A Gold LEED certified office building is owned by BASF
and gained a gold certificate for new construction and major
renovation. The building was studied for 2 days resulting in 10
responds. A silver LEED certified office building is owned by
Unilever and gained a silver certificate for commercial interiors. The
building was studied for 7 days resulting in 84 responds.
The results showed that all buildings had no significant difference
regarding occupants’ satisfaction with the amount of lighting, noise
level, odor and access to the outdoor view. There was significant
difference between occupants’ satisfaction in LEED certified
buildings and the traditional building regarding the thermal
environment and the perception of the general environment (colors,
carpet and decoration. The findings suggest that careful design could
lead to a certified building that enhances the thermal environment and
the perception of the indoor environment leading to energy
consumption without scarifying occupants’ satisfaction.
Abstract: The majority of contemporary insulation materials
commonly used in the building industry is made from non-renewable
raw materials; furthermore, their production often brings high energy
costs. A long-term trend as far as sustainable development is
concerned has been the reduction of energy and material demands of
building material production. One of the solutions is the possibility of
using easily renewable natural raw material sources which are
considerably more ecological and their production is mostly less
energy-consuming compared to the production of normal insulations
(mineral wool, polystyrene). The paper describes the results of
research focused on the development of thermal and acoustic
insulation materials based on natural fibres intended for floor
constructions. Given the characteristic open porosity of natural fibre
materials, the hygrothermal behaviour of the developed materials was
studied. Especially the influence of relative humidity and temperature
on thermal insulation properties was observed.
Abstract: The climate change is a main parameter which affects the element of hydrological cycle especially runoff. Then, the purpose of this study is to determine the impact of the climate change on surface runoff using land use map on 2008 and daily weather data during January 1, 1979 to September 30, 2010 for SWAT model. SWAT continuously simulate time model and operates on a daily time step at basin scale. The results present that the effect of temperature change cannot be clearly presented on the change of runoff while the rainfall, relative humidity and evaporation are the parameters for the considering of runoff change. If there are the increasing of rainfall and relative humidity, there is also the increasing of runoff. On the other hand, if there is the increasing of evaporation, there is the decreasing of runoff.
Abstract: A numerical investigation of the fin efficiency and temperature distribution of an annular fin under dehumidification has been presented in this paper. The non-homogeneous second order differential equation that describes the temperature distribution from the fin base to the fin tip has been solved using the central finite difference method. The effects of variations in parameters including relative humidity, air temperature, air face velocity on temperature distribution and fin efficiency are investigated and compared with those under fully dry fin conditions. Also, the effect of fin pitch on the dimensionless temperature has been studied.
Abstract: Understanding the behavior of airflow in a room is essential for building designers to provide the most efficient design of ventilation system, and having acceptable indoor air quality. This trend is the motive to solve the relationship between airflow parameters and thermal comfort. This paper investigates airflow characteristics, indoor air quality (IAQ), and the thermal comfort (TC) in a ventilated room with a displacement ventilation system using three dimensional CFD code [AirPak 2.0.6]. After validation of the code, a numerical study is executed for a typical room with dimensions of 5m by 3m by 3m height according to a variety of supply air velocities, supply air temperature and supply air relative humidity. The finite volume method and the indoor zero equation turbulence models are employed for solving the governing equations numerically. The temperature field and the mean age of air (MAA) in the modeled room for a displacement ventilation system are determined according to a variety of the above parameters. The variable air volume (VAV) systems with different supply air velocity are applicable to control room air temperature for a displacement ventilation system.
Abstract: The objective of this work was to examine the
changes in the microstructure and macro physical properties caused
by the carbonation of normalised CEM II mortar. Samples were
prepared and subjected to accelerated carbonation at 20°C, 65%
relative humidity and 20% CO2 concentration. On the microstructure
scale, the evolutions of the cumulative pore volume, pore size
distribution, and specific surface area during carbonation were
calculated from the adsorption desorption isotherms of nitrogen. We
also examined the evolution of macro physical properties such as the
porosity accessible to water, the gas permeability, and thermal
conductivity. The conflict between the results of nitrogen porosity
and water porosity indicated that the porous domains explored using
these two techniques are different and help to complementarily
evaluate the effects of carbonation. This is a multi-scale study where
results on microstructural changes can help to explain the evolution
of macro physical properties.
Abstract: A numerical study has been conducted to investigate the influence of fin pitch and relative humidity on the heat transfer performance of the fin-and-tube heat exchangers having plain fin geometry under dehumidifying conditions. The analysis is done using the ratio between the heat transfer coefficients in totally wet conditions and those in totally dry conditions using the appropriate correlations for both dry and wet conditions. For a constant relative humidity, it is found that the heat transfer coefficient increases with the increase of the air frontal velocity. By contrast, the fin efficiency decreases when the face velocity is increased. Apparently, this phenomenon is attributed to the path of condensate drainage. For the influence of relative humidity, the results showed an increase in heat transfer performance and a decrease in wet fin efficiency when relative humidity increases. This is due to the higher amount of mass transfer encountered at higher relative humidity. However, it is found that the effect of fin pitch on the heat transfer performance depends strongly on the face velocity. At lower frontal velocity the heat transfer increases with fin pitch. Conversely, an increase in fin pitch gives lower heat transfer coefficients when air velocity is increased.
Abstract: Exposure to ambient air pollution has been linked to a
number of health outcomes, starting from modest transient changes in
the respiratory tract and impaired pulmonary function, continuing to
restrict activity/reduce performance and to the increase emergency
rooms visits, hospital admissions or mortality. The increase of
allergenic symptoms has been associated with air contaminants such
as ozone, particulate matter, fungal spores and pollen.
Considering the potential relevance of crossed effects of nonbiological
pollutants and airborne pollens and fungal spores on
allergy worsening, the aim of this work was to evaluate the influence
of non-biological pollutants (O3 and PM10) and meteorological
parameters on the concentrations of pollen and fungal spores using
multiple linear regressions.
The data considered in this study were collected in Oporto which
is the second largest Portuguese city, located in the North. Daily
mean of O3, PM10, pollen and fungal spore concentrations,
temperature, relative humidity, precipitation, wind velocity, pollen
and fungal spore concentrations, for 2003, 2004 and 2005 were
considered. Results showed that the 90th percentile of the adjusted
coefficient of determination, P90 (R2aj), of the multiple regressions
varied from 0.613 to 0.916 for pollen and from 0.275 to 0.512 for
fungal spores. O3 and PM10 showed to have some influence on the
biological pollutants. Among the meteorological parameters
analysed, temperature was the one that most influenced the pollen
and fungal spores airborne concentrations. Relative humidity also
showed to have some influence on the fungal spore dispersion.
Nevertheless, the models for each pollen and fungal spore were
different depending on the analysed period, which means that the
correlations identified as statistically significant can not be, even so,
consistent enough.
Abstract: A better understanding of cloud forest characteristic in a tropical montane cloud forest at Khao Nan, Nakhon Si Thammarat on climatic, vegetation, soil and hydrology were studied during 18-21 April 2007. The results showed that as air temperature at Sanyen cloud forest increased, the percent relative humidity decreased. The amount of solar radiation at Sanyen cloud forest had a positive association with the amount of solar radiation at Parah forest. The amount of solar radiation at Sanyen cloud forest was very low with a range of 0-19 W/m2. On the other hand, the amount of solar radiation at Parah forest was high with a range of 0-1000 W/m2. There was no difference between leaf width, leaf length, leaf thickness and leaf area with increasing in elevations. As the elevations increased, bush height and tree height decreased. There was no association between bush width and bush ratio with elevation. As the elevations increased, the percent epiphyte cover and the percent soil moisture increased but water temperature, conductivity, and dissolved oxygen decreased. The percent soil moistures and organic contents were higher at elevations above 900 m than elevations below.
Abstract: The 'wind-rain' house has a courtyard with glazed
roof, which allows more direct sunlight to come into indoor spaces
during the winter. The glazed roof can be partially opened or closed
and automatically controlled to provide natural ventilation in order to
adjust for indoor thermal conditions and the roof area can be shaded
by reflective insulation materials during the summer. Two field
studies for evaluating indoor thermal conditions of the two 'windrain'
houses have been carried out by author in 2009 and 2010.
Indoor and outdoor air temperature and relative humidity adjacent to
floor and ceiling of the two sample houses were continuously tested
at 15-minute intervals, 24 hours a day during the winter months.
Based on field study data, this study investigates relationships
between building design and indoor thermal condition of the 'windrain'
house to improve the future house design for building thermal
comfort and energy efficiency
Abstract: Heat Index describes the combined effect of
temperature and humidity on human body. This combined effect is
causing a serious threat to the health of people because of the
changing climate. With climate change, climate variability and thus
the occurrence of heat waves is likely to increase. Evidence is
emerging from the analysis of long-term climate records of an
increase in the frequency and duration of extreme temperature events
in all over Bangladesh particularly during summer. Summer season
has prolonged while winters have become short in Bangladesh.
Summers have become hotter and thus affecting the lives of the
people engaged in outdoor activities during scorching sun hours. In
2003 around 62 people died due to heat wave across the country. In
this paper Bangladesh is divided in four regions and heat index has
been calculated from 1960 to 2010 in these regions of the country.
The aim of this paper is to identify the spots most vulnerable to heat
strokes and heat waves due to high heat index. The results show
upward trend of heat index in almost all the regions of Bangladesh.
The highest increase in heat index value has been observed in areas
of South-west region and North-west Region. The highest change in
average heat index has been found in Jessore by almost 5.50C.
Abstract: This paper presents the experimental results of the
investigation of various properties related to the durability and longterm
performance of mortars made of Fly Ash blended cement, FA
and Ordinary Portland cement, OPC. The properties that were
investigated in an experimental program include; equilibration of
specimen in different relative humidity, determination of total
porosity, compressive strength, chloride permeability index, and
electrical resistivity. Fly Ash blended cement mortar specimens
exhibited 10% to 15% lower porosity when measured at equilibrium
conditions in different relative humidities as compared to the
specimens made of OPC mortar, which resulted in 6% to 8% higher
compressive strength of FA blended cement mortar specimens. The
effects of ambient relative humidity during sample equilibration on
porosity and strength development were also studied. For specimens
equilibrated in higher relative humidity conditions, such as 75%, the
total porosity of different mortar specimens was between 35% to 50%
less than the porosity of samples equilibrated in 12% relative
humidity, consequently leading to higher compressive strengths of
these specimens.A valid statistical correlation between values of
compressive strength, porosity and the degree of saturation was
obtained. Measured values of chloride permeability index of fly ash
blended cement mortar were obtained as one fourth to one sixth of
those measured for OPC mortar specimens, which indicates high
resistance against chloride ion penetration in FA blended cement
specimens, hence resulting in a highly durable mortar.
Abstract: The determination of sugars in foods is very
significant. Their relation in fact, can affect the chemical and
sensorial quality of the matrix (e.g., sweetness, pH, total acidity,
microbial stability, global acceptability) and can provide information
on food to optimize several selected technological processes. Three
stages of ripeness (green, yellow and red) of tomatoes (Lycopersicon
Esculentum cv. Elegance) at different harvest dates were evaluated.
Fruit from all harvests were exposed to different of ozone doses
(0.25, 0.50 and 1 mg O3/g tomatoes) and clean air for 5 day at 15
°C±2 and 90-95 % relative humidity. Then, fruits were submitted for
extraction and analysis after a day from the finish of exposure of each
stage. The concentrations of the glucose and fructose increased in the
tomatoes which were subjected to ozone treatments.
Abstract: In order to avoid the potentially devastating
consequences of global warming and climate change, the carbon
dioxide “CO2" emissions caused due to anthropogenic activities must
be reduced considerably. This paper presents the first study
examining the feasibility of carbon sequestration in construction and
demolition “C&D" waste. Experiments were carried out in a self
fabricated Batch Reactor at 40ºC, relative humidity of 50-70%, and
flow rate of CO2 at 10L/min for 1 hour for water-to-solids ratio of 0.2
to 1.2. The effect of surface area was found by comparing the
theoretical extent of carbonation of two different sieve sizes (0.3mm
and 2.36mm) of C&D waste. A 38.44% of the theoretical extent of
carbonation equating to 4% CO2 sequestration extent was obtained
for C&D waste sample for 0.3mm sieve size. Qualitative,
quantitative and morphological analyses were done to validate
carbonate formation using X-ray diffraction “X.R.D.," thermal
gravimetric analysis “T.G.A., “X-Ray Fluorescence Spectroscopy
“X.R.F.," and scanning electron microscopy “S.E.M".
Abstract: Continuous measurements and multivariate methods are applied in researching the effects of energy consumption on indoor air quality (IAQ) in a Finnish one-family house. Measured data used in this study was collected continuously in a house in Kuopio, Eastern Finland, during fourteen months long period. Consumption parameters measured were the consumptions of district heat, electricity and water. Indoor parameters gathered were temperature, relative humidity (RH), the concentrations of carbon dioxide (CO2) and carbon monoxide (CO) and differential air pressure. In this study, self-organizing map (SOM) and Sammon's mapping were applied to resolve the effects of energy consumption on indoor air quality. Namely, the SOM was qualified as a suitable method having a property to summarize the multivariable dependencies into easily observable two-dimensional map. Accompanying that, the Sammon's mapping method was used to cluster pre-processed data to find similarities of the variables, expressing distances and groups in the data. The methods used were able to distinguish 7 different clusters characterizing indoor air quality and energy efficiency in the study house. The results indicate, that the cost implications in euros of heating and electricity energy vary according to the differential pressure, concentration of carbon dioxide, temperature and season.