Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: Appropriate ventilation in a classroom is helpful for
enhancing air exchange rate and student concentration. This study
focuses on the effects of fenestration in a four-story school building by
performing numerical simulation of a building when considering
indoor and outdoor environments simultaneously. The wind profile
function embedded in PHOENICS code was set as the inlet boundary
condition in a suburban environment. Sixteen fenestration
combinations were compared in a classroom containing thirty seats.
This study evaluates mean age of air (AGE) and airflow pattern of a
classroom on different floors. Considering both wind profile and
fenestration effects, the airflow on higher floors is channeled toward
the area near ceiling in a room and causes older mean age of air in the
breathing zone. The results in this study serve as a useful guide for
enhancing natural ventilation in a typical school building.