Abstract: This paper presents the experimental results of
comparison between leakage currents and discharge currents. The leakage currents were obtained on polluted porcelain insulator.
Whereas, the discharge currents were obtained on lightly artificial
polluted porcelain specimen. The conducted measurements were
leakage current or discharge current and applied voltage. The insulator or specimen was in a hermetically sealed chamber, and the
current waveforms were analyzed using FFT.
The result indicated that the leakage current (LC) on low RH condition the fifth harmonic would be visible, and followed by the
seventh harmonic. The insulator had capacitive property. Otherwise,
on 99% relative humidity, the fifth harmonic would also be visible,
and the phase angle reached up to 12.2 degree. Whereas, on discharge current, the third harmonic would be visible, and followed
by fifth harmonic. The third harmonic would increase as pressure reduced. On this condition, the specimen had a non-linear characteristics
Abstract: This paper presents the experimental results of silicone rubber housing material for 24kV lightning arrester under artificial accelerated ageing test based on IEC 61109 specifications. Specimens having inclined and alternated shed made of HTV silicone rubber with ATH content and having leakage distance 625 mm were tested continuously 1000 hrs in artificial salt fog chamber. After 1000 hrs of salt fog ageing test, obviously surface erosion was observed on trunk between the upper large shed and the lower small shed near the energized end. Decreasing in hydrophobicity and increasing in hardness were measured on tested specimen comparing with new specimen. Chemical analysis by ATR-FTIR confirmed the observation results.
Abstract: In this paper, for the first time, a two-dimensional
(2D) analytical drain current model for sub-100 nm multi-layered
gate material engineered trapezoidal recessed channel (MLGMETRC)
MOSFET: a novel design is presented and investigated using
ATLAS and DEVEDIT device simulators, to mitigate the large gate
leakages and increased standby power consumption that arise due to
continued scaling of SiO2-based gate dielectrics. The twodimensional
(2D) analytical model based on solution of Poisson-s
equation in cylindrical coordinates, utilizing the cylindrical
approximation, has been developed which evaluate the surface
potential, electric field, drain current, switching metric: ION/IOFF
ratio and transconductance for the proposed design. A good
agreement between the model predictions and device simulation
results is obtained, verifying the accuracy of the proposed analytical
model.
Abstract: This paper presents the simulation results of electric field and potential distributions along surface of silicone rubber polymer insulators under clean and various contamination conditions with/without water droplets. Straight sheds insulator having leakage distance 290 mm was used in this study. Two type of contaminants, playwood dust and cement dust, have been studied the effect of contamination on the insulator surface. The objective of this work is to comparison the effect of contamination on potential and electric field distributions along the insulator surface when water droplets exist on the insulator surface. Finite element method (FEM) is adopted for this work. The simulation results show that contaminations have no effect on potential distribution along the insulator surface while electric field distributions are obviously depended on contamination conditions.
Abstract: In this paper, multilayered coreless printed circuit
board (PCB) step-down power transformers for DC-DC converter
applications have been designed, manufactured and evaluated. A set
of two different circular spiral step-down transformers were
fabricated in the four layered PCB. These transformers have been
modelled with the assistance of high frequency equivalent circuit and
characterized with both sinusoidal and square wave excitation. This
paper provides the comparative results of these two different
transformers in terms of their resistances, self, leakage, mutual
inductances, coupling coefficient and also their energy efficiencies.
The operating regions for optimal performance of these transformers
for power transfer applications are determined. These transformers
were tested for the output power levels of about 30 Watts within the
input voltage range of 12-50 Vrms. The energy efficiency for these
step down transformers is observed to be in the range of 90%-97% in
MHz frequency region.
Abstract: This paper presents the experimental results of
leakage current waveforms which appears on porcelain insulator
surface due to existence of artificial pollutants. The tests have been
done using the chemical compounds of NaCl, Na2SiO3, H2SO4, CaO,
Na2SO4, KCl, Al2SO4, MgSO4, FeCl3, and TiO2. The insulator
surface was coated with those compounds and dried. Then, it was
tested in the chamber where the high voltage was applied. Using
correspondence analysis, the result indicated that the fundamental
harmonic of leakage current was very close to the applied voltage
and third harmonic leakage current was close to the yielded leakage
current amplitude. The first harmonic power was correlated to first
harmonic amplitude of leakage current, and third harmonic power
was close to third harmonic one. The chemical compounds of H2SO4
and Na2SiO3 affected to the power factor of around 70%. Both are the
most conductive, due to the power factor drastically increase among
the chemical compounds.
Abstract: Acoustic Imaging based sound localization using microphone
array is a challenging task in digital-signal processing.
Discrete Fourier transform (DFT) based near-field acoustical holography
(NAH) is an important acoustical technique for sound source
localization and provide an efficient solution to the ill-posed problem.
However, in practice, due to the usage of small curtailed aperture
and its consequence of significant spectral leakage, the DFT could
not reconstruct the active-region-of-sound (AROS) effectively, especially
near the edges of aperture. In this paper, we emphasize the
fundamental problems of DFT-based NAH, provide a solution to
spectral leakage effect by the extrapolation based on linear predictive
coding and 2D Tukey windowing. This approach has been tested to
localize the single and multi-point sound sources. We observe that
incorporating extrapolation technique increases the spatial resolution,
localization accuracy and reduces spectral leakage when small curtail
aperture with a lower number of sensors accounts.
Abstract: This paper presents the experimental results of silicone rubber polymer insulators for 22 kV systems under salt water dip wheel test based on IEC 62217. Straight shed silicone rubber polymer insulators having leakage distance 685 mm were tested continuously 30,000 cycles. One test cycle includes 4 positions, energized, de-energized, salt water dip and deenergized, respectively. For one test cycle, each test specimen remains stationary for about 40 second in each position and takes 8 second for rotate to next position. By visual observation, sever surface erosion was observed on the trunk near the energized end of tested specimen. Puncture was observed on the upper shed near the energized end. In addition, decreasing in hydrophobicity and increasing in hardness were measured on tested specimen comparing with new specimen. Furthermore, chemical analysis by ATR-FTIR was conducted in order to elucidate the chemical change of tested specimens comparing with new specimen.
Abstract: The cost of damage to the non-structural systems in
critical facilities like nuclear power plants and hospitals can exceed
80% of the total cost of damage during an earthquake. The failure of
nonstructural components, especially, piping systems led to leakage of
water and subsequent shut-down of hospitals immediately after the
event. Consequently, the evaluation of performance of these types of
structural configurations has become necessary to mitigate the risk and
to achieve reliable designs.
This paper focuses on a methodology to evaluate the static and
dynamic characteristics of complex actual piping system based on
NFPA-13 and SMACNA guidelines. The result of this study revealed
that current piping system subjected to design lateral force and design
spectrum based on UBC-97 was failed in both cases and mode shapes
between piping system and building structure were very different
Abstract: As the disfunctions of the information society and
social development progress, intrusion problems such as malicious
replies, spam mail, private information leakage, phishing, and
pharming, and side effects such as the spread of unwholesome
information and privacy invasion are becoming serious social
problems. Illegal access to information is also becoming a problem as
the exchange and sharing of information increases on the basis of the
extension of the communication network. On the other hand, as the
communication network has been constructed as an international,
global system, the legal response against invasion and cyber-attack
from abroad is facing its limit. In addition, in an environment where
the important infrastructures are managed and controlled on the basis
of the information communication network, such problems pose a
threat to national security. Countermeasures to such threats are
developed and implemented on a yearly basis to protect the major
infrastructures of information communication. As a part of such
measures, we have developed a methodology for assessing the
information protection level which can be used to establish the
quantitative object setting method required for the improvement of the
information protection level.
Abstract: Privacy issues commonly discussed among
researchers, practitioners, and end-users in pervasive healthcare.
Pervasive healthcare systems are applications that can support
patient-s need anytime and anywhere. However, pervasive healthcare
raises privacy concerns since it can lead to situations where patients
may not be aware that their private information is being shared and
becomes vulnerable to threat. We have systematically analyzed the
privacy issues and present a summary in tabular form to show the
relationship among the issues. The six issues identified are medical
information misuse, prescription leakage, medical information
eavesdropping, social implications for the patient, patient difficulties
in managing privacy settings, and lack of support in designing
privacy-sensitive applications. We narrow down the issues and chose
to focus on the issue of 'lack of support in designing privacysensitive
applications' by proposing a privacy-sensitive architecture
specifically designed for pervasive healthcare monitoring systems.
Abstract: In this paper, gate leakage current has been mitigated
by the use of novel nanoscale MOSFET with Source/Drain-to-Gate
Non-overlapped and high-k spacer structure for the first time. A
compact analytical model has been developed to study the gate
leakage behaviour of proposed MOSFET structure. The result
obtained has found good agreement with the Sentaurus Simulation.
Fringing gate electric field through the dielectric spacer induces
inversion layer in the non-overlap region to act as extended S/D
region. It is found that optimal Source/Drain-to-Gate Non-overlapped
and high-k spacer structure has reduced the gate leakage current to
great extent as compared to those of an overlapped structure. Further,
the proposed structure had improved off current, subthreshold slope
and DIBL characteristic. It is concluded that this structure solves the
problem of high leakage current without introducing the extra series
resistance.
Abstract:
Innovation is becoming more and more important in
modern society. There are a lot of researches on different kinds of
innovation but marketing innovation is one kind of innovation that
has not been studied frequently before. Marketing innovation is
defined as a new way in which companies can market themselves to
potential or existing customers.
The study shows some key elements for marketing innovation that
are worth paying attention to when implementing marketing
innovation projects. Examples of such key elements are: paying
attention to the neglected market, suitable market segmentatio
reliable market information, public relationship, increased customer
value, combination of market factors, explore different marketing
channels and the use of technology in combination with what? Beside
the key elements for marketing innovation, we also present some
risks that may occur, such as cost, market uncertainty, information
leakage, imitation and overdependence on experience.
By proposing a set of indicators to measure marketing innovation,
the article offers solutions for marketing innovation implementation
so that any organization can achieve optimal results.
Abstract: In this paper we investigate the electrical
characteristics of a new structure of gate all around strained silicon
nanowire field effect transistors (FETs) with dual dielectrics by
changing the radius (RSiGe) of silicon-germanium (SiGe) wire and
gate dielectric. Indeed the effect of high-κ dielectric on Field Induced
Barrier Lowering (FIBL) has been studied. Due to the higher electron
mobility in tensile strained silicon, the n-type FETs with strained
silicon channel have better drain current compare with the pure Si
one. In this structure gate dielectric divided in two parts, we have
used high-κ dielectric near the source and low-κ dielectric near the
drain to reduce the short channel effects. By this structure short
channel effects such as FIBL will be reduced indeed by increasing
the RSiGe, ID-VD characteristics will be improved. The leakage
current and transfer characteristics, the threshold-voltage (Vt), the
drain induced barrier height lowering (DIBL), are estimated with
respect to, gate bias (VG), RSiGe and different gate dielectrics. For
short channel effects, such as DIBL, gate all around strained silicon
nanowire FET have similar characteristics with the pure Si one while
dual dielectrics can improve short channel effects in this structure.
Abstract: This paper presents the experimental results of
discharge current phenomena on various humidity, temperature,
pressure and pollutant conditions of epoxy resin specimen. The
leakage distance of specimen was 3 cm, that it was supplied by high
voltage. The polluted condition was given with NaCl artificial
pollutant. The conducted measurements were discharge current and
applied voltage. The specimen was put in a hermetically sealed
chamber, and the current waveforms were analyzed with FFT.
The result indicated that on discharge condition, the fifth
harmonics still had dominant, rather than third one. The third
harmonics tent to be appeared on low pressure heavily polluted
condition, and followed by high humidity heavily polluted condition.
On the heavily polluted specimen, the peaks discharge current points
would be high and more frequent. Nevertheless, the specimen still
had capacitive property. Besides that, usually discharge current
points were more frequent. The influence of low pressure was still
dominant to be easier to discharge. The non-linear property would be
appear explicitly on low pressure and heavily polluted condition.
Abstract: The major part of light weight timber constructions
consists of insulation. Mineral wool is the most commonly used
insulation due to its cost efficiency and easy handling. The fiber
orientation and porosity of this insulation material enables flowthrough.
The air flow resistance is low. If leakage occurs in the
insulated bay section, the convective flow may cause energy losses
and infiltration of the exterior wall with moisture and particles. In
particular the infiltrated moisture may lead to thermal bridges and
growth of health endangering mould and mildew. In order to prevent
this problem, different numerical calculation models have been
developed. All models developed so far have a potential for
completion. The implementation of the flow-through properties of
mineral wool insulation may help to improve the existing models.
Assuming that the real pressure difference between interior and
exterior surface is larger than the prescribed pressure difference in the
standard test procedure for mineral wool ISO 9053 / EN 29053,
measurements were performed using the measurement setup for
research on convective moisture transfer “MSRCMT".
These measurements show, that structural inhomogeneities of
mineral wool effect the permeability only at higher pressure
differences, as applied in MSRCMT. Additional microscopic
investigations show, that the location of a leak within the
construction has a crucial influence on the air flow-through and the
infiltration rate. The results clearly indicate that the empirical values
for the acoustic resistance of mineral wool should not be used for the
calculation of convective transfer mechanisms.
Abstract: In this work, the physical based device model of
AlGaN/GaN high electron mobility transistors (HEMTs) has been
established and the corresponding device operation behavior has
been investigated also by using Sentaurus TCAD from Synopsys.
Advanced AlGaN/GaN hetero-structures with GaN cap layer and AlN
spacer have been considered and the GaN cap layer and AlN spacer
are found taking important roles on the gate leakage blocking and
off-state breakdown voltage enhancement.
Abstract: A Comparison and evaluation of the different
condition monitoring (CM) techniques was applied experimentally
on RC e.g. Dynamic cylinder pressure and crankshaft Instantaneous
Angular Speed (IAS), for the detection and diagnosis of valve faults
in a two - stage reciprocating compressor for a programme of
condition monitoring which can successfully detect and diagnose a
fault in machine. Leakage in the valve plate was introduced
experimentally into a two-stage reciprocating compressor. The effect
of the faults on compressor performance was monitored and the
differences with the normal, healthy performance noted as a fault
signature been used for the detection and diagnosis of faults.
The paper concludes with what is considered to be a unique
approach to condition monitoring. First, each of the two most useful
techniques is used to produce a Truth Table which details the
circumstances in which each method can be used to detect and
diagnose a fault. The two Truth Tables are then combined into a
single Decision Table to provide a unique and reliable method of
detection and diagnosis of each of the individual faults introduced
into the compressor. This gives accurate diagnosis of compressor
faults.
Abstract: The hydraulic actuated excavator, being a non-linear
mobile machine, encounters many uncertainties. There are
uncertainties in the hydraulic system in addition to the uncertain
nature of the load. The simulation results obtained in this study show
that there is a need for intelligent control of such machines and in
particular interval type-2 fuzzy controller is most suitable for
minimizing the position error of a typical excavator-s bucket under
load variations. We consider the model parameter uncertainties such
as hydraulic fluid leakage and friction. These are uncertainties which
also depend up on the temperature and alter bulk modulus and
viscosity of the hydraulic fluid. Such uncertainties together with the
load variations cause chattering of the bucket position. The interval
type-2 fuzzy controller effectively eliminates the chattering and
manages to control the end-effecter (bucket) position with positional
error in the order of few millimeters.
Abstract: Modern applications realized onto FPGAs exhibit high connectivity demands. Throughout this paper we study the routing constraints of Virtex devices and we propose a systematic methodology for designing a novel general-purpose interconnection network targeting to reconfigurable architectures. This network consists of multiple segment wires and SB patterns, appropriately selected and assigned across the device. The goal of our proposed methodology is to maximize the hardware utilization of fabricated routing resources. The derived interconnection scheme is integrated on a Virtex style FPGA. This device is characterized both for its high-performance, as well as for its low-energy requirements. Due to this, the design criterion that guides our architecture selections was the minimal Energy×Delay Product (EDP). The methodology is fully-supported by three new software tools, which belong to MEANDER Design Framework. Using a typical set of MCNC benchmarks, extensive comparison study in terms of several critical parameters proves the effectiveness of the derived interconnection network. More specifically, we achieve average Energy×Delay Product reduction by 63%, performance increase by 26%, reduction in leakage power by 21%, reduction in total energy consumption by 11%, at the expense of increase of channel width by 20%.