Abstract: A unique combination of adsorption and
electrochemical regeneration with a proprietary adsorbent material
called Nyex 100 was introduced at the University of Manchester for
waste water treatment applications. Nyex 100 is based on graphite
intercalation compound. It is non porous and electrically conducing
adsorbent material. This material exhibited very small BET surface
area i.e. 2.75 m2g-1, in consequence, small adsorptive capacities for
the adsorption of various organic pollutants were obtained. This work
aims to develop composite adsorbent material essentially capable of
electrochemical regeneration coupled with improved adsorption
characteristics. An organic dye, acid violet 17 was used as standard
organic pollutant. The developed composite material was
successfully electrochemically regenerated using a DC current of 1 A
for 60 minutes. Regeneration efficiency was maintained at around
100% for five adsorption-regeneration cycles.
Abstract: The purpose of this research was develop a biological
nutrient removal (BNR) system which has low energy consumption, sludge production, and land usage. These indicate that BNR system could be a alternative of future wastewater treatment in ubiquitous
city(U-city). Organics and nitrogen compounds could be removed by this system so that secondary or tertiary stages of wastewater treatment satisfy their standards. This system was composed of oxic and anoxic
filter filed with PVDC and POM media. Anoxic/oxic filter system operated under empty bed contact time of 4 hours by increasing
recirculation ratio from 0 to 100 %. The system removals of total nitrogen and COD were 76.3% and 93%, respectively. To be observed
internal behavior in this system SCOD, NH3-N, and NO3-N were
conducted and removal shows range of 25~100%, 59~99%, and
70~100%, respectively.
Abstract: The information revealed by derivatives can help to
better characterize digital near-end crosstalk signatures with the
ultimate goal of identifying the specific aggressor signal.
Unfortunately, derivatives tend to be very sensitive to even low
levels of noise. In this work we approximated the derivatives of both
quiet and noisy digital signals using a wavelet-based technique. The
results are presented for Gaussian digital edges, IBIS Model digital
edges, and digital edges in oscilloscope data captured from an actual
printed circuit board. Tradeoffs between accuracy and noise
immunity are presented. The results show that the wavelet technique
can produce first derivative approximations that are accurate to
within 5% or better, even under noisy conditions. The wavelet
technique can be used to calculate the derivative of a digital signal
edge when conventional methods fail.
Abstract: The breakdown strength characteristic of Low Density
Polyethylene films (LDPE) under DC voltage application and the
effect of water absorption have been studied. Mainly, our experiment
was investigated under two conditions; dry and heavy water
absorption. Under DC ramp voltage, the result found that the
breakdown strength under heavy water absorption has a lower value
than dry condition. In order to clarify the effect, the temperature rise of
film was observed using non contact thermograph until the occurrence
of the electrical breakdown and the conduction current of the sample
was also measured in correlation with the thermograph measurement.
From the observations, it was shown that under the heavy water
absorption, the hot spot in the samples appeared at lower voltage. At
the same voltage the temperature of the hot spot and conduction
current was higher than that under the dry condition. The measurement
result has a good correlation between the existence of a critical field
for conduction current and thermograph observation. In case of the
heavy water absorption, the occurrence of the threshold field was
earlier than the dry condition as result lead to higher of conduction
current and the temperature rise appears after threshold field was
significantly increased in increasing of field. The higher temperature
rise was caused by the higher current conduction as the result the
insulation leads to breakdown to the lower field application.
Abstract: A simple method for the simultaneous determination
of hippuric acid and benzoic acid in urine using reversed-phase high
performance liquid chromatography was described. Chromatography
was performed on a Nova-Pak C18 (3.9 x 150 mm) column with a
mobile phase of mixed solution methanol: water: acetic acid
(20:80:0.2) and UV detection at 254 nm. The calibration curve was
linear within concentration range at 0.125 to 6.0 mg/ml of hippuric
acid and benzoic acid. The recovery, accuracy and coefficient
variance of hippuric acid were 104.54%, 0.2% and 0.2% respectively
and for benzoic acid were 98.48%, 1.25% and 0.60% respectively.
The detection limit of this method was 0.01ng/l for hippuric acid and
0.06ng/l for benzoic acid. This method has been applied to the
analysis of urine samples from the suspected of toluene abuser or
glue sniffer among secondary school students at Johor Bahru.
Abstract: A generalized unified power quality conditioner
(GUPQC) by using three single-phase three-level voltage source
converters (VSCs) connected back-to-back through a common dc
link is proposed in this paper as a new custom power device for a
three-feeder distribution system. One of the converters is connected
in shunt with one feeder for mitigation of current harmonics and
reactive power compensation, while the other two VSCs are
connected in series with the other two feeders to maintain the load
voltage sinusoidal and at constant level. A new control scheme based
on synchronous reference frame is proposed for series converters.
The simulation analysis on compensation performance of GUPQC
based on PSCAD/EMTDC is reported.
Abstract: Biological reactions of individuals of a testing animal
to toxic substance are unique and can be used as an indication of the
existing of toxic substance. However, to distinguish such phenomenon
need a very complicate system and even more complicate to analyze
data in 3 dimensional. In this paper, a system to evaluate in vitro
biological activities to acute toxicity of stochastic self-affine
non-stationary signal of 3D goldfish swimming by using fractal
analysis is introduced. Regular digital camcorders are utilized by
proposed algorithm 3DCCPC to effectively capture and construct 3D
movements of the fish. A Critical Exponent Method (CEM) has been
adopted as a fractal estimator. The hypothesis was that the swimming
of goldfish to acute toxic would show the fractal property which
related to the toxic concentration. The experimental results supported
the hypothesis by showing that the swimming of goldfish under the
different toxic concentration has fractal properties. It also shows that
the fractal dimension of the swimming related to the pH value of FD Ôëê
0.26pH + 0.05. With the proposed system, the fish is allowed to swim
freely in all direction to react to the toxic. In addition, the trajectories
are precisely evaluated by fractal analysis with critical exponent
method and hence the results exhibit with much higher degree of
confidence.
Abstract: This paper presents the DC voltage control design of D-STATCOM when the D-STATCOM is used for load voltage regulation. Although, the DC voltage can be controlled by active current of the D-STATCOM, reactive current still affects the DC voltage. To eliminate this effect, the control strategy with elimination effect of the reactive current is proposed and the results of the control with and without the elimination the effect of the reactive current are compared. For obtaining the proportional and integral gains of the PI controllers, the symmetrical optimum and genetic algorithms methods are applied. The stability margin of these methods are obtained and discussed in detail. In addition, the performance of the DC voltage control based on symmetrical optimum and genetic algorithms methods are compared. Effectiveness of the controllers designed was verified through computer simulation performed by using Power System Tool Block (PSB) in SIMULINK/MATLAB. The simulation results demonstrated that the DC voltage control proposed is effective in regulating DC voltage when the DSTATCOM is used for load voltage regulation.
Abstract: In this paper a novel scheme for watermarking digital
audio during its compression to MPEG-1 Layer III format is
proposed. For this purpose we slightly modify some of the selected
MDCT coefficients, which are used during MPEG audio
compression procedure. Due to the possibility of modifying different
MDCT coefficients, there will be different choices for embedding the
watermark into audio data, considering robustness and transparency
factors. Our proposed method uses a genetic algorithm to select the
best coefficients to embed the watermark. This genetic selection is
done according to the parameters that are extracted from the
perceptual content of the audio to optimize the robustness and
transparency of the watermark. On the other hand the watermark
security is increased due to the random nature of the genetic
selection. The information of the selected MDCT coefficients that
carry the watermark bits, are saves in a database for future extraction
of the watermark. The proposed method is suitable for online MP3
stores to pursue illegal copies of musical artworks. Experimental
results show that the detection ratio of the watermarks at the bitrate
of 128kbps remains above 90% while the inaudibility of the
watermark is preserved.
Abstract: In this paper, a new encoding algorithm of spectral envelope based on NLMS in G.729.1 for VoIP is proposed. In the TDAC part of G.729.1, the spectral envelope and MDCT coefficients extracted in the weighted CELP coding error (lower-band) and the higher-band input signal are encoded. In order to reduce allocation bits for spectral envelope coding, a new quantization algorithm based on NLMS is proposed. Also, reduced bits are used to enhance sound quality. The performance of the proposed algorithm is evaluated by sound quality and bit reduction rates in clean and frame loss conditions.
Abstract: Applying corona wind as a novel technique can lead
to a great level of heat and mass transfer augmentation by using very
small amount of energy. Enhancement of forced flow evaporation
rate by applying electric field (corona wind) has been experimentally
evaluated in this study. Corona wind produced by a fine wire
electrode which is charged with positive high DC voltage impinges
to water surface and leads to evaporation enhancement by disturbing
the saturated air layer over water surface. The study was focused on
the effect of corona wind velocity, electrode spacing and air flow
velocity on the level of evaporation enhancement. Two sets of
experiments, i.e. with and without electric field, have been
conducted. Data obtained from the first experiment were used as
reference for evaluation of evaporation enhancement at the presence
of electric field. Applied voltages ranged from corona threshold
voltage to spark over voltage at 1 kV increments. The results showed
that corona wind has great enhancement effect on water evaporation
rate, but its effectiveness gradually diminishes by increasing air flow
velocity. Maximum enhancements were 7.3 and 3.6 for air velocities
of 0.125 and 1.75 m/s, respectively.
Abstract: PARIS (Personal Archiving and Retrieving Image
System) is an experiment personal photograph library, which includes
more than 80,000 of consumer photographs accumulated within a
duration of approximately five years, metadata based on our proposed
MPEG-7 annotation architecture, Dozen Dimensional Digital Content
(DDDC), and a relational database structure. The DDDC architecture
is specially designed for facilitating the managing, browsing and
retrieving of personal digital photograph collections. In annotating
process, we also utilize a proposed Spatial and Temporal Ontology
(STO) designed based on the general characteristic of personal
photograph collections. This paper explains PRAIS system.
Abstract: IMCS is Integrated Monitoring and Control System for
thermal power plant. This system consists of mainly two parts; controllers and OIS (Operator Interface System). These two parts are
connected by Ethernet-based communication. The controller side of communication is managed by CNet module and OIS side is managed
by data server of OIS. CNet module sends the data of controller to data
server and receives commend data from data server. To minimizes or
balance the load of data server, this module buffers data created by controller at every cycle and send buffered data to data server on request of data server. For multiple data server, this module manages
the connection line with each data server and response for each request
from multiple data server. CNet module is included in each controller
of redundant system. When controller fail-over happens on redundant system, this module can provide data of controller to data sever
without loss. This paper presents three main features – separation of get task, usage of ring buffer and monitoring communication status –of CNet module to carry out these functions.
Abstract: Consumer electronics are pervasive. It is impossible to
imagine a household or office without DVD players, digital cameras,
printers, mobile phones, shavers, electrical toothbrushes, etc. All
these devices operate at different voltage levels ranging from 1.8 to
20 VDC, in the absence of universal standards. The voltages
available are however usually 120/230 VAC at 50/60 Hz. This
situation makes an individual electrical energy conversion system
necessary for each device. Such converters usually involve several
conversion stages and often operate with excessive losses and poor
reliability. The aim of the project presented in this paper is to design
and implement a multi-channel DC/DC converter system,
customizing the output voltage and current ratings according to the
requirements of the load. Distributed, multi-agent techniques will be
applied for the control of the DC/DC converters.
Abstract: We evaluated the effect of sensory (direct current
(DC), 600μA) and motor (monophasic current, pulse duration 300μs,
100 Hz, 2.5-3mA) intensities of cathodal electrical stimulation (ES)
current to release VEGF and biomechanical properties of wound. 54
male Sprague-dawley rats were randomly assigned into one control
and two experimental groups. A full thickness skin incision was
made on animals- dorsal region. The experimental groups received
ES for 1h/day and every other day. VEGF expression was measured
in skin on the 7th day after surgical incision and tensile strength was
measured on 21st day. On the 7th day, the values of skin VEGF in the
sensory group were significantly greater than those of the other
groups (p < 0.05). Sensory and Motor intensity stimulation, can not
improve the biomechanical properties of the repaired wounds.
It seems the mechanical environment induced by sensory and
motor intensity of electrical stimulation, could not simulate the role
of normal daily stress and strain to maturation of collagen fibers and
their cross links. Further work is needed to determine the relationship
between VEGF expression after ES and its effect on tensile strength
of healed wound.
Abstract: In the present simulation work, an attempt is made to study the switching dynamics of an optically controlled 4HSiC thyristor power semiconductor device with the use of GaAs optically triggered power transistor. The half-cell thyristor has the forward breakdown of 200 V and reverse breakdown of more than 1000 V. The optically controlled thyristor has a rise time of 0.14 μs and fall time of 0.065 μs. The turn-on and turn-off delays are 0.1 μs and 0.06 μs, respectively. In addition, this optically controlled thyristor is used as a control switch for the DC-DC Boost converter. The pn-diode used for the converter has the forward drop of 2.8 V and reverse breakdown of around 400 V.
Abstract: Dynamic Causal Modeling (DCM) functional
Magnetic Resonance Imaging (fMRI) is a promising technique to
study the connectivity among brain regions and effects of stimuli
through modeling neuronal interactions from time-series
neuroimaging. The aim of this study is to study characteristics of a
mirror neuron system (MNS) in elderly group (age: 60-70 years old).
Twenty volunteers were MRI scanned with visual stimuli to study a
functional brain network. DCM was employed to determine the
mechanism of mirror neuron effects. The results revealed major
activated areas including precentral gyrus, inferior parietal lobule,
inferior occipital gyrus, and supplementary motor area. When visual
stimuli were presented, the feed-forward connectivity from visual
area to conjunction area was increased and forwarded to motor area.
Moreover, the connectivity from the conjunction areas to premotor
area was also increased. Such findings can be useful for future
diagnostic process for elderly with diseases such as Parkinson-s and
Alzheimer-s.
Abstract: Repetitive control and feedback dithering modulation
are applied to a single-phase voltage source inverter, with an aim to
eliminate harmonics and stabilize the inverter under load variations.
The proposed control and modulation scheme comprise multiple loops
of feedback, which helps improve inverter performance and
robustness. Experimental results show that the designed inverter
exhibits very low distortion at its output with THD of about 0.3%
under different load variations.
Abstract: Nowadays there are several grid connected converter
in the grid system. These grid connected converters are generally the
converters of renewable energy sources, industrial four quadrant
drives and other converters with DC link. These converters are
connected to the grid through a three phase bridge. The standards
prescribe the maximal harmonic emission which could be easily
limited with high switching frequency. The increased switching
losses can be reduced to the half with the utilization of the wellknown
Flat-top modulation. The suggested control method is the
expansion of the Flat-top modulation with which the losses could be
also reduced to the half compared to the Flat-top modulation.
Comparing to traditional control these requirements can be
simultaneously satisfied much better with the DLF (DC Link
Floating) method.
Abstract: The object of this paper is to design and analyze a
proportional – integral (PI) control for positive output elementary
super lift Luo converter (POESLLC), which is the start-of-the-art
DC-DC converter. The positive output elementary super lift Luo
converter performs the voltage conversion from positive source
voltage to positive load voltage. This paper proposes a
development of PI control capable of providing the good static and
dynamic performance compared to proportional – integralderivative
(PID) controller. Using state space average method
derives the dynamic equations describing the positive output
elementary super lift luo converter and PI control is designed. The
simulation model of the positive output elementary super lift Luo
converter with its control circuit is implemented in
Matlab/Simulink. The PI control for positive output elementary
super lift Luo converter is tested for transient region, line changes,
load changes, steady state region and also for components
variations.