Abstract: This study applies the inverse method and three- dimensional CFD commercial software in conjunction with the experimental temperature data to investigate the heat transfer and fluid flow characteristics of the plate-fin heat sink in a closed rectangular enclosure for various values of fin height. The inverse method with the finite difference method and the experimental temperature data is applied to determine the heat transfer coefficient. The k-ε turbulence model is used to obtain the heat transfer and fluid flow characteristics within the fins. To validate the accuracy of the results obtained, the comparison of the average heat transfer coefficient is made. The calculated temperature at selected measurement locations on the plate-fin is also compared with experimental data.
Abstract: A 3D-conjugate numerical investigation was conducted to predict heat transfer characteristics in a rectangular cross-sectional micro-channel employing simultaneously developing Tow-phase flows. The sole purpose for analyzing two phase flow heat transfer in rectangular micro channel is to pin point what are the different factors affecting this phenomenon. Different methods and techniques have been undertaken to analyze the equations arising constituting the flow of heat from gas phase to liquid phase and vice versa.Different models of micro channels have been identified and analyzed. How the geometry of micro channels affects their activity i.e. of circular and non-circular geometry has also been reviewed. To the study the results average Nusselt no plotted against the Reynolds no has been taken into consideration to study average heat exchange in micro channels against applied heat flux. High heat fluxes up to 140 W/cm2 were applied to investigate micro-channel thermal characteristics.
Abstract: In this study, the enhancement of the heat release performance of an extruded-type heat sink to prepare the large-capacity solar inverter thru the flow holes in the base plate near the heat sources was investigated. Optimal location and number of the holes in the baseplate were determined by using a commercial computation program. The heat release performance of the shape-modified heat sink was measured experimentally and compared with that of the simulation. The heat sink with 12 flow holes in the 18-mm-thick base plate has a 8.1% wider heat transfer area, a 2.5% more mass flow of air, and a 2.7% higher heat release rate than those of the original heat sink. Also, the surface temperature of the base plate was lowered 1.5oC by the holes.
Abstract: In this study, heat release performances of the three extruded-type heat sinks can be used in inverter for solar power generation were evaluated. Numbers of fins in the heat sinks (namely E-38, E-47 and E-76) were 38, 47 and 76, respectively. Heat transfer areas of them were 1.8, 1.9 and 2.8m2. The heat release performances of E-38, E-47 and E-76 heat sinks were measured as 79.6, 81.6 and 83.2%, respectively. The results of heat release performance show that the larger amount of heat transfer area the higher heat release rate. While on the other, in this experiment, variations of mass flow rates caused by different cross sectional areas of the three heat sinks may not be the major parameter of the heat release. Despite the 47.4% increment of heat transfer area of E-76 heat sink than that of E-47 one, its heat release rate was higher by only 2.0%; this suggests that its heat transfer area need to be optimized.
Abstract: In heat sinks, the flow within the core exhibits separation and hence does not lend itself to simple analytical boundary layer or duct flow analysis of the wall friction. In this paper, we present some findings from an experimental and numerical study aimed to obtain physical insight into the influence of the presence of the shield and its position on the hydraulic and thermal performance of square pin fin heat sink without top by-pass. The variations of the Nusselt number and friction factor are obtained under varied parameters, such as the Reynolds number and the shield position. The numerical code is validated by comparing the numerical results with the available experimental data. It is shown that, there is a good agreement between the temperature predictions based on the model and the experimental data. Results show that, as the presence of the shield, the heat transfer of fin array is enhanced and the flow resistance increased. The surface temperature distribution of the heat sink base is more uniform when the dimensionless shield position equals to 1/3 or 2/3. The comprehensive performance evaluation approach based on identical pumping power criteria is adopted and shows that the optimum shield position is at x/l=0.43.
Abstract: In order to compare the performance of the carbon dioxide and HFC-125 heat pumps for medium-and high-temperature heating, both heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler were fixed at 40/90°C and 40/150°C.The results shows that the HFC-125 heat pump has 6% higher heating COP than carbon dioxide heat pump when the heat sink exit temperature is fixed at 90ºC, while the latter outperforms the former when the heat sink exit temperature is fixed at 150ºC under the simulation conditions considered in the present study.
Abstract: Shape memory alloy (SMA) actuators have found a
wide range of applications due to their unique properties such as high
force, small size, lightweight and silent operation. This paper presents
the development of compact (SMA) actuator and cooling system in
one unit. This actuator is developed for multi-fingered hand. It
consists of nickel-titanium (Nitinol) SMA wires in compact forming.
The new arrangement insulates SMA wires from the human body by
housing it in a heat sink and uses a thermoelectric device for rejecting
heat to improve the actuator performance. The study uses
optimization methods for selecting the SMA wires geometrical
parameters and the material of a heat sink. The experimental work
implements the actuator prototype and measures its response.
Abstract: This article experimentally investigates the
thermal performance of thermoelectric air-cooling module
which comprises a thermoelectric cooler (TEC) and an
air-cooling heat sink. The influences of input current and heat
load are determined. And performances under each situation
are quantified by thermal resistance analysis. Since TEC
generates Joule heat, this nature makes construction of thermal
resistance network difficult. To simplify the analysis, this
article emphasizes on the resistance heat load might meet when
passing through the device. Therefore, the thermal resistances
in this paper are to divide temperature differences by heat load.
According to the result, there exists an optimum input current
under every heating power. In this case, the optimum input
current is around 6A or 7A. The performance of the heat sink
would be improved with TEC under certain heating power and
input current, especially at a low heat load. According to the
result, the device can even make the heat source cooler than the
ambient. However, TEC is not always effective at every heat
load and input current. In some situation, the device works
worse than the heat sink without TEC. To determine the
availability of TEC, this study figures out the effective
operating region in which the TEC air-cooling module works
better than the heat sink without TEC. The result shows that
TEC is more effective at a lower heat load. If heat load is too
high, heat sink with TEC will perform worse than without TEC.
The limit of this device is 57W. Besides, TEC is not helpful if
input current is too high or too low. There is an effective range
of input current, and the range becomes narrower when the heat
load grows.
Abstract: In a nuclear reactor Loss of Coolant accident (LOCA)
considers wide range of postulated damage or rupture of pipe in the
heat transport piping system. In the case of LOCA with/without
failure of emergency core cooling system in a Pressurised Heavy
water Reactor, the Pressure Tube (PT) temperature could rise
significantly due to fuel heat up and gross mismatch of the heat
generation and heat removal in the affected channel. The extent and
nature of deformation is important from reactor safety point of view.
Experimental set-ups have been designed and fabricated to simulate
ballooning (radial deformation) of PT for 220 MWe IPHWRs.
Experiments have been conducted by covering the CT by ceramic
fibers and then by submerging CT in water of voided PTs. In both
the experiments, it is observed that ballooning initiates at a
temperature around 665´┐¢C and complete contact between PT and
Caldaria Tube (CT) occurs at around 700´┐¢C approximately. The
strain rate is found to be 0.116% per second. The structural integrity
of PT is retained (no breach) for all the experiments. The PT heatup
is found to be arrested after the contact between PT and CT, thus
establishing moderator acting as an efficient heat sink for IPHWRs.
Abstract: In order to improve the simulation effects of space cold
black environment, this paper described a rectangular channel plate
heat sink. By using fluid mechanics theory and finite element method,
the internal fluid flow and heat transfer in heat sink was numerically
simulated to analyze the impact of channel structural on fluid flow and
heat transfer. The result showed that heat sink temperature uniformity
is well, and the impact of channel structural on the heat sink
temperature uniformity is not significant. The channel depth and
spacing are important factors which affect the fluid flow and heat
transfer in the heat sink. The two factors of heat transfer and resistance
need to be considered comprehensively to determine the optimal flow
structure parameters.
Abstract: In the present study, the pressure drop and laminar convection heat transfer characteristics of nanofluids in microchannel heat sink with square duct are numerically investigated. The water based nanofluids created with Al2O3 and CuO particles in four different volume fractions of 0%, 0.5%, 1%, 1.5% and 2% are used to analyze their effects on heat transfer and the pressure drop. Under the laminar, steady-state flow conditions, the finite volume method is used to solve the governing equations of heat transfer. Mixture Model is considered to simulate the nanofluid flow. For verification of used numerical method, the results obtained from numerical calculations were compared with the results in literature for both pure water and the nanofluids in different volume fractions. The distributions of the particles in base fluid are assumed to be uniform. The results are evaluated in terms of Nusselt number, the pressure drop and heat transfer enhancement. Analysis shows that the nanofluids enhance heat transfer while the Reynolds number and the volume fractions are increasing. The best overall enhancement was obtained at φ=%2 and Re=100 for CuO-water nanofluid.
Abstract: This study presents the numerical simulation of
optimum pin-fin heat sink with air impinging cooling by using
Taguchi method. 9 L ( 4 3 ) orthogonal array is selected as a plan for
the four design-parameters with three levels. The governing
equations are discretized by using the
control-volume-based-finite-difference method with a power-law
scheme on the non-uniform staggered grid. We solved the coupling of
the velocity and the pressure terms of momentum equations using
SIMPLEC algorithm. We employ the k −ε two-equations
turbulence model to describe the turbulent behavior. The parameters
studied include fin height H (35mm-45mm), inter-fin spacing a , b ,
and c (2 mm-6.4 mm), and Reynolds number ( Re = 10000- 25000).
The objective of this study is to examine the effects of the fin
spacings and fin height on the thermal resistance and to find the
optimum group by using the Taguchi method. We found that the fin
spacings from the center to the edge of the heat sink gradually
extended, and the longer the fin’s height the better the results. The
optimum group is 3 1 2 3 H a b c . In addition, the effects of parameters are
ranked by importance as a , H , c , and b .
Abstract: This paper presents the results of the experimental
tests of the cooling performance of a 12,000-Btu/h modified air
conditioner (referred to as M-AC) that use the ground as a heat sink
of a condenser. In the tests, cooling capacity of M-AC with an
optimal length of a condensing coil as well as life expectancy of
copper coil buried underground were investigated. The lengths of
copper coil fabricated and used as condenser coil of M-AC were set
at 67, 50, 40 and 30 m whereas that of a 12,000-Btu/h conventional
split-type air conditioner (referred to as C-AC) was about 22 m. The
results showed that the ground can absorb heat rejected from a
condenser of M-AC. The coefficient of performance (COP) of C-AC
was about 2.5 whereas those of M-AC were found to be higher. It
was found that the values of COP of M-AC with condensing coils of
67, 50 and 40 m long were about 6.9, 5.5 and 3.3, respectively, while
that of 30-m-long one was found to be about 2.1. The electrical
consumptions of M-AC were found lower than that of C-AC in the
range of 11.5 – 15.5%. Additionally, life expectancy of underground
condensing coil of M-AC was found to be over 7 years.
Abstract: In this experiment, we investigated the performance of
two types of heat sink, swaged- and extruded-type, used in the inverter
of industrial electricity generator. The swaged-type heat sink has 62
fins, and the extruded-type has 38 fins having the same dimension as
that of the swaged-type. But the extruded-type heat sink maintains the
same heat transfer area by the laterally waved surface which has 1 mm
in radius. As a result, the swaged- and extruded-type heat sinks
released 71% and 64% of the heat incoming to the heat sink,
respectively. The other incoming heat were naturally convected and
radiated to the ambient. In spite of 40% decrease in number of fins, the
heat release performance of the extruded-type heat sink was lowered
only 7% than that of the swaged-type. We believe that, this shows the
increment of effective heat transfer area by the laterally waved surface
of fins and the better heat transfer property of the extruded-type heat
sink.
Abstract: The effect of streamwise conduction on the thermal
characteristics of forced convection for nanofluidic flow in
rectangular microchannel heat sinks under isothermal wall has been
investigated. By applying the fin approach, models with and without
streamwise conduction term in the energy equation were developed
for hydrodynamically and thermally fully-developed flow. These two
models were solved to obtain closed form analytical solutions for the
nanofluid and solid wall temperature distributions and the analysis
emphasized details of the variations induced by the streamwise
conduction on the nanofluid heat transport characteristics. The effects
of the Peclet number, nanoparticle volume fraction, thermal
conductivity ratio on the thermal characteristics of forced convection
in microchannel heat sinks are analyzed. Due to the anomalous
increase in the effective thermal conductivity of nanofluid compared
to its base fluid, the effect of streamwise conduction is expected to be
more significant. This study reveals the significance of the effect of
streamwise conduction under certain conditions of which the
streamwise conduction should not be neglected in the forced
convective heat transfer analysis of microchannel heat sinks.