Abstract: The thermal damping of a dynamic vibrating micromirror is an important factor affecting the design of MEMS based actuator systems. In the development process of new micromirror systems, assessing the extent of energy loss due to thermal damping accurately and predicting the performance of the system is very essential. In this paper, the depth of the thermal penetration layer at different eigenfrequencies and the temperature variation distributions surrounding a vibrating micromirror is analyzed. The thermal penetration depth corresponds to the thermal boundary layer in which energy is lost which is a measure of the thermal damping is found out. The energy is mainly dissipated in the thermal boundary layer and thickness of the layer is an important parameter. The detailed thermoacoustics is used to model the air domain surrounding the micromirror. The thickness of the boundary layer, temperature variations and thermal power dissipation are analyzed for a Si based torsional mode micromirror. It is found that thermal penetration depth decreases with eigenfrequency and hence operating the micromirror at higher frequencies is essential for reducing thermal damping. The temperature variations and thermal power dissipations at different eigenfrequencies are also analyzed. Both frequency-response and eigenfrequency analyses are done using COMSOL Multiphysics software.
Abstract: We propose an integral tracking control method for a piezoelectric actuator system. The proposed method achieves the output tracking without requiring any hysteresis observer or schemes to compensate the hysteresis effect. With the proposed control law, the system is converted into the standard singularly perturbed model. Using Tikhonov-s theorem, we guarantee that the tracking error can be reduced to arbitrarily small bound. A numerical example is given to illustrate the effectiveness of our proposed method.
Abstract: Shape memory alloy (SMA) actuators have found a
wide range of applications due to their unique properties such as high
force, small size, lightweight and silent operation. This paper presents
the development of compact (SMA) actuator and cooling system in
one unit. This actuator is developed for multi-fingered hand. It
consists of nickel-titanium (Nitinol) SMA wires in compact forming.
The new arrangement insulates SMA wires from the human body by
housing it in a heat sink and uses a thermoelectric device for rejecting
heat to improve the actuator performance. The study uses
optimization methods for selecting the SMA wires geometrical
parameters and the material of a heat sink. The experimental work
implements the actuator prototype and measures its response.
Abstract: In this paper, we propose a hardware and software
design method for automotive Electronic Control Units (ECU)
considering the functional safety. The proposed ECU is considered for
the application to Electro-Mechanical Actuator systems and the
validity of the design method is shown by the application to the
Electro-Mechanical Brake (EMB) control system which is used as a
brake actuator in Brake-By-Wire (BBW) systems. The importance of a
functional safety-based design approach to EMB ECU design has been
emphasized because of its safety-critical functions, which are executed
with the aid of many electric actuators, sensors, and application
software. Based on hazard analysis and risk assessment according to
ISO26262, the EMB system should be ASIL-D-compliant, the highest
ASIL level. To this end, an external signature watchdog and an
Infineon 32-bit microcontroller TriCore are used to reduce risks
considering common-cause hardware failure. Moreover, a software
design method is introduced for implementing functional
safety-oriented monitoring functions based on an asymmetric dual
core architecture considering redundancy and diversity. The validity
of the proposed ECU design approach is verified by using the EMB
Hardware-In-the-Loop (HILS) system, which consists of the EMB
assembly, actuator ECU, a host PC, and a few debugging devices.
Furthermore, it is shown that the existing sensor fault tolerant control
system can be used more effectively for mitigating the effects of
hardware and software faults by applying the proposed ECU design
method.