Abstract: This paper aims to discuss the hydrophilicity about the anodic aluminum oxide (AAO) template with titania nanotubes (NTs). The AAO templates with pore size diameters of 20-250 nm were generated by anodizing 6061 aluminum alloy substrates in acid solution of sulfuric acid (H2SO4), oxalic acid (COOH)2, and phosphoric acid (H3PO4), respectively. TiO2-NTs were grown on AAO templates by the sol-gel deposition process successfully. The water contact angle on AAO/TiO2-NTs surface was lower compared to the water contact angle on AAO surface. So, the characteristic of hydrophilicity was significantly associated with the AAO pore size and what kinds of materials were immersed variables.
Abstract: This article experimentally investigates the
thermal performance of thermoelectric air-cooling module
which comprises a thermoelectric cooler (TEC) and an
air-cooling heat sink. The influences of input current and heat
load are determined. And performances under each situation
are quantified by thermal resistance analysis. Since TEC
generates Joule heat, this nature makes construction of thermal
resistance network difficult. To simplify the analysis, this
article emphasizes on the resistance heat load might meet when
passing through the device. Therefore, the thermal resistances
in this paper are to divide temperature differences by heat load.
According to the result, there exists an optimum input current
under every heating power. In this case, the optimum input
current is around 6A or 7A. The performance of the heat sink
would be improved with TEC under certain heating power and
input current, especially at a low heat load. According to the
result, the device can even make the heat source cooler than the
ambient. However, TEC is not always effective at every heat
load and input current. In some situation, the device works
worse than the heat sink without TEC. To determine the
availability of TEC, this study figures out the effective
operating region in which the TEC air-cooling module works
better than the heat sink without TEC. The result shows that
TEC is more effective at a lower heat load. If heat load is too
high, heat sink with TEC will perform worse than without TEC.
The limit of this device is 57W. Besides, TEC is not helpful if
input current is too high or too low. There is an effective range
of input current, and the range becomes narrower when the heat
load grows.