Abstract: In this study, the enhancement of the heat release performance of an extruded-type heat sink to prepare the large-capacity solar inverter thru the flow holes in the base plate near the heat sources was investigated. Optimal location and number of the holes in the baseplate were determined by using a commercial computation program. The heat release performance of the shape-modified heat sink was measured experimentally and compared with that of the simulation. The heat sink with 12 flow holes in the 18-mm-thick base plate has a 8.1% wider heat transfer area, a 2.5% more mass flow of air, and a 2.7% higher heat release rate than those of the original heat sink. Also, the surface temperature of the base plate was lowered 1.5oC by the holes.
Abstract: In this experiment, we investigated the performance of
two types of heat sink, swaged- and extruded-type, used in the inverter
of industrial electricity generator. The swaged-type heat sink has 62
fins, and the extruded-type has 38 fins having the same dimension as
that of the swaged-type. But the extruded-type heat sink maintains the
same heat transfer area by the laterally waved surface which has 1 mm
in radius. As a result, the swaged- and extruded-type heat sinks
released 71% and 64% of the heat incoming to the heat sink,
respectively. The other incoming heat were naturally convected and
radiated to the ambient. In spite of 40% decrease in number of fins, the
heat release performance of the extruded-type heat sink was lowered
only 7% than that of the swaged-type. We believe that, this shows the
increment of effective heat transfer area by the laterally waved surface
of fins and the better heat transfer property of the extruded-type heat
sink.