Abstract: Many existing amusement parks have been operated
with assistance of a variety of information and communications
technologies to design friendly and efficient service systems for
tourists. However, these systems leave various levels of decisions to
tourists to make by themselves. This incurs pressure on tourists and
thereby bringing negative experience in their tour. This paper
proposes a smart amusement park system to offer each tourist the
GPS-based customized plan without tourists making decisions by
themselves. The proposed system consists of the mobile app
subsystem, the central subsystem, and the detecting/counting
subsystem. The mobile app subsystem interacts with the central
subsystem. The central subsystem performs the necessary computing
and database management of the proposed system. The
detecting/counting subsystem aims to detect and compute the number
of visitors to an attraction. Experimental results show that the
proposed system can not only work well, but also provide an
innovative business operating model for owners of amusement parks.
Abstract: We investigated ecotoxicity and performed experiment
for removing ZnO nanoparticles in water. Short term exposure of
hatching test using fertilized eggs (O. latipes) showed deformity in
5ppm of ZnO nanoparticles solution. And in 10ppm ZnO nanoparticles
solution delayed hatching was observed. Hereine, chemical
precipitation method was suggested for removing ZnO nanoparticles
in water. The precipitated ZnO nanoparticles showed the form of ZnS
after addition of Na2S, and the form of Zn3(PO4)2 for Na2HPO4. The
removal efficiency of ZnO nanoparticles in water was closed to 100%
for two cases. In ecotoxicity evaluation of as-precipitated ZnS and
Zn3(PO4)2, they did not cause any acute toxicity for D. magna. It is
noted that this precipitation treatment of ZnO is effective to reduce the
potential cytotoxicity.
Abstract: In internet of things (IoT) system, the communication
scheme with reliability and low power is required to connect a
terminal. Cooperative communication can achieve reliability and
lower power than multiple-input multiple-output (MIMO) system.
Cooperative communication increases the reliability with low
power, but decreases a throughput. It has a weak point that the
communication throughput is decreased. In this paper, a novel scheme
is proposed to increase the communication throughput. The novel
scheme is a transmission structure that increases transmission rate.
A decoding scheme according to the novel transmission structure is
proposed. Simulation results show that the proposed scheme increases
the throughput without bit error rate (BER) performance degradation.
Abstract: Ultraviolet photocatalytic oxidation (UV-PCO)
technology has been recommended as a green approach to health
indoor environment when it is integrated into mechanical ventilation
systems for inorganic and organic compounds removal as well as
energy saving due to less outdoor air intakes. Although much research
has been devoted to UV-PCO, limited information is available on the
UV-PCO behavior tested by the mixtures in literature. This project
investigated UV-PCO performance and by-product generation using a
single and a mixture of acetone and MEK at 100 ppb each in a
single-pass duct system in an effort to obtain knowledge associated
with competitive photochemical reactions involved in. The
experiments were performed at 20 % RH, 22 °C, and a gas flow rate of
128 m3/h (75 cfm). Results show that acetone and MEK mutually
reduced each other’s PCO removal efficiency, particularly negative
removal efficiency for acetone. These findings were different from
previous observation of facilitatory effects on the adsorption of
acetone and MEK on photocatalyst surfaces.
Abstract: There are a number of Distributed Generations (DGs)
installed in microgrid, which may have diverse path and direction of
power flow or fault current. The overcurrent protection scheme for the
traditional radial type distribution system will no longer meet the
needs of microgrid protection. Integrating the Intelligent Electronic
Device (IED) and a Supervisory Control and Data Acquisition
(SCADA) with IEC 61850 communication protocol, the paper
proposes a Microgrid Protection Management System (MPMS) to
protect power system from the fault. In the proposed method, the
MPMS performs logic programming of each IED to coordinate their
tripping sequence. The GOOSE message defined in IEC 61850 is used
as the transmission information medium among IEDs. Moreover, to
cope with the difference in fault current of microgrid between
grid-connected mode and islanded mode, the proposed MPMS applies
the group setting feature of IED to protect system and robust
adaptability. Once the microgrid topology varies, the MPMS will
recalculate the fault current and update the group setting of IED.
Provided there is a fault, IEDs will isolate the fault at once. Finally, the
Matlab/Simulink and Elipse Power Studio software are used to
simulate and demonstrate the feasibility of the proposed method.
Abstract: Hollow section for bridge columns has some
advantages. However, current seismic design codes do not provide
design regulations for hollow bridge piers. There have been many
experimental studied for hollow reinforced concrete piers in the world.
But, Study for hollow section for bridge piers in Korea has been begun
with approximately 2000s. There has been conducted experimental
study for hollow piers of flexural controlled sections by Yeungnam
University, Sung kyunkwan University, Korea Expressway
Corporation in 2009. This study concluded that flexural controlled
sections for hollow piers showed the similar behavior to solid sections.
And there have been conducted experimental study for hollow piers of
compression controlled sections by Yeungnam University, Korea
Institute of Construction Technology in 2012. This study concluded
that compression controlled sections for hollow piers showed
compression fracture of concrete in inside wall face. Samsung
Construction & Trading Corporation has been conducted study with
Yeungnam University for reduce the quantity of reinforcement details
about hollow piers. Reduce the quantity of reinforcement details are
triangular cross tie. This study concluded that triangular reinforcement
details showed the similar behavior as compared with existing
reinforcement details.
Abstract: This paper aims to study the heat transfer and fluid
flow characteristics of nanofluids used in spray cooling systems. The
effect of spray height, type of nanofluids and concentration of
nanofluids are numerically investigated. Five different nanofluids
such as AgH2O, Al2O3, CuO, SiO2 and TiO2 with volume fraction
range of 0.5% to 2.5% are used. The results revealed that the heat
transfer performance decreases as spray height increases. It is found
that TiO2 has the highest transfer coefficient among other nanofluids.
In dilute spray conditions, low concentration of nanofluids is
observed to be more effective in heat removal in a spray cooling
system.
Abstract: This paper is aimed to study combustion characteristics
of low NOx burner using petroleum cokes as fuel. The petroleum coke,
which is produced through the oil refining process, is an attractive fuel
in terms of its high heating value and low price. But petroleum coke is
a challenging fuel because of its low volatile content, high sulfur and
nitrogen content, which give rise to undesirable emission
characteristics and low ignitability. Therefore, the research and
development regarding the petroleum coke burner is needed for
applying this industrial system. In this study, combustion and emission
characteristics of petroleum cokes burner are experimentally
investigated in an industrial steam boiler. The low NOx burner is
designed to control fuel and air mixing to achieve staged combustion,
which, in turn reduces both flame temperature and oxygen. Air
distribution ratio of triple staged air is optimized experimentally. The
result showed that NOx concentration is lowest when overfire air is
used, and the burner function at a fuel rich condition. That is, the
burner is operated at the equivalence ratio of 1.67 and overall
equivalence ratio including overfire air is kept 0.87.
Abstract: Recently attention has been focused on incomplete
spinal cord injuries (SCI) to the central spine caused by pressure on
parts of the white matter conduction pathway, such as the pyramidal
tract. In this paper, we focus on a training robot designed to assist with
primary walking-pattern training. The target patient for this training
robot is relearning the basic functions of the usual walking pattern; it is
meant especially for those with incomplete-type SCI to the central
spine, who are capable of standing by themselves but not of
performing walking motions. From the perspective of human
engineering, we monitored the operator’s actions to the robot and
investigated the movement of joints of the lower extremities, the
circumference of the lower extremities, and exercise intensity with the
machine. The concept of the device was to provide mild training
without any sudden changes in heart rate or blood pressure, which will
be particularly useful for the elderly and disabled. The mechanism of
the robot is modified to be simple and lightweight with the expectation
that it will be used at home.
Abstract: This study analyzed the effect of area variables and
economic variables on the length of each period of the project in order
to analyze the effect of agreement rate on project implementation in
housing renewal projects. In conclusion, as can be seen from these
results, a low agreement rate may not translate into project promotion,
and a higher agreement rate may not translate into project delay. The
expectation of the policy is that the lower the agreement rate, the more
projects would be promoted, but that is not the actual effect. From a
policy consistency viewpoint, changing the agreement rate frequently,
depending on the decision of the public, is not reasonable. The policy
of using agreement rate as a necessary condition for project
implementation should be reconsidered.
Abstract: This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.
Abstract: The nickel-manganese (Ni-Mn) alloy coating prepared
from DC electrodeposition process in sulphamate bath was studied.
The effects of process parameters, such as current density and
electrolyte composition, on the cathodic current efficiency,
microstructure, internal stress and mechanical properties were
investigated. Because of its crucial effect on the application to the
electroforming of microelectronic components, the development of
low internal stress coating with high leveling power was emphasized.
It was found that both the coating’s manganese content and the
cathodic current efficiency increased with the raise in current density.
In addition, the internal stress of the deposited coating showed
compressive nature at low current densities while changed to tensile
one at higher current densities. Moreover, the metallographic
observation, X-ray diffraction measurement, and polarization curve
measurement were conducted. It was found that the Ni-Mn coating
consisted of nano-sized columnar grains and the maximum hardness of
the coating was associated with (111) preferred orientation in the
microstructure. The grain size was refined along with the increase in
the manganese content of the coating, which accordingly, raised its
hardness and resistance to annealing softening. In summary, the
Ni-Mn coating prepared at lower current density of 1-2 A/dm2 had low
internal stress, high leveling power, and better corrosion resistance.
Abstract: An approach was evaluated for the retrieval of soil
moisture of bare soil surface using bistatic scatterometer data in the
angular range of 200 to 700 at VV- and HH- polarization. The
microwave data was acquired by specially designed X-band (10
GHz) bistatic scatterometer. The linear regression analysis was done
between scattering coefficients and soil moisture content to select the
suitable incidence angle for retrieval of soil moisture content. The 250
incidence angle was found more suitable. The support vector
regression analysis was used to approximate the function described
by the input output relationship between the scattering coefficient and
corresponding measured values of the soil moisture content. The
performance of support vector regression algorithm was evaluated by
comparing the observed and the estimated soil moisture content by
statistical performance indices %Bias, root mean squared error
(RMSE) and Nash-Sutcliffe Efficiency (NSE). The values of %Bias,
root mean squared error (RMSE) and Nash-Sutcliffe Efficiency
(NSE) were found 2.9451, 1.0986 and 0.9214 respectively at HHpolarization.
At VV- polarization, the values of %Bias, root mean
squared error (RMSE) and Nash-Sutcliffe Efficiency (NSE) were
found 3.6186, 0.9373 and 0.9428 respectively.
Abstract: Establishing a secure communication of Internet
conferences for participants is very important. Before starting the
conference, all the participants establish a common conference key to
encrypt/decrypt communicated messages. It enables participants to
exchange the secure messages. Nevertheless, in the conference, if
there are any malicious participants who may try to upset the key
generation process causing other legal participants to obtain a different
conference key. In this article, we propose an improved conference
key agreement with fault-tolerant capability. The proposed scheme
can filter malicious participants at the beginning of the conference to
ensure that all participants obtain the same conference key. Compare
with other schemes, our scheme is more secure and efficient than
others.
Abstract: A solution methodology without using integral
transformation is proposed to develop analytical solutions for
transient heat conduction in nonuniform hollow cylinders with
time-dependent boundary condition at the outer surface. It is shown
that if the thermal conductivity and the specific heat of the medium
are in arbitrary polynomial function forms, the closed solutions of the
system can be developed. The influence of physical properties on the
temperature distribution of the system is studied. A numerical
example is given to illustrate the efficiency and the accuracy of the
solution methodology.
Abstract: This study makes an integrated investigation on how
life satisfaction is associated with the Korean game users'
psychological variables (self-esteem, game and life self- efficacy),
social variables (bonding and bridging social capital), and
demographic variables (age, gender). The data used for the empirical
analysis came from a representative sample survey conducted in South
Korea. Results show that self-esteem and game efficacy were an
important antecedent to the degree of users’ life satisfaction. Both
bonding social capital and bridging social capital enhance the level of
the users’ life satisfaction. The importance of perspectives as well as
their implications for the game users and further associated research is
explored.
Abstract: The objective of the study is to assess the
implementation of LED lighting into forest machine work in the dark.
In addition, the paper includes a wide variety of important and
relevant safety and health parameters. In modern, computerized work
in the cab of forest machines, artificial illumination is a demanding
task when performing duties, such as the visual inspections of wood
and computer calculations. We interviewed entrepreneurs and
gathered the following as the most pertinent themes: (1) safety, (2)
practical problems, and (3) work with LED lighting. The most
important comments were in regards to the practical problems of
LED lighting. We found indications of technical problems in
implementing LED lighting, like snow and dirt on the surfaces of
lamps that dim the emission of light. Moreover, service work in the
dark forest is dangerous and increases the risks of on-site accidents.
We also concluded that the amount of blue light to the eyes should be
assessed, especially, when the drivers are working in a semi-dark cab.
Abstract: This paper presents thermal annealing de-wetting
technique for the preparation of porous metal membrane for Thin
Film Encapsulation (TFE) application. Thermal annealing de-wetting
experimental results reveal that pore size formation in porous metal
membrane depend upon i.e. 1. The substrate at which metal is
deposited, 2. Melting point of metal used for porous metal cap layer
membrane formation, 3. Thickness of metal used for cap layer, 4.
Temperature used for formation of porous metal membrane. In order
to demonstrate this technique, Silver (Ag) was used as a metal for
preparation of porous metal membrane on amorphous silicon (a-Si)
and silicon oxide. The annealing of the silver thin film of various
thicknesses was performed at different temperature. Pores in porous
silver film were analyzed using Scanning Electron Microscope
(SEM). In order to check the usefulness of porous metal film for TFE
application, the porous silver film prepared on amorphous silicon (a-
Si) and silicon oxide was released using XeF2 and VHF, respectively.
Finally, guide line and structures are suggested to use this porous
membrane for robust TFE application.
Abstract: Currently there are many use of threaded reinforcing
bars in construction fields because those do not need additional screw
processing when connecting reinforcing bar by threaded coupler. In
this study, reinforced concrete bridge piers using threaded rebar
coupler system at the plastic hinge area were tested to evaluate seismic
performance. The test results showed that threads of the threaded rebar
coupler system could be loosened while under tension-compression
cyclic loading because tolerance and rib face angle of a threaded rebar
coupler system are greater than that of a conventional ribbed rebar
coupler system. As a result, cracks were concentrated just outside of
the mechanical coupler and stiffness of reinforced concrete bridge pier
decreased. Therefore, it is recommended that connection ratio of
mechanical couplers in one section shall be below 50% in order that
cracks are not concentrated just outside of the mechanical coupler.
Also, reduced stiffness of the specimen should be considered when
using the threaded rebar coupler system.
Abstract: In recent years, fire accidents have been steadily
increased and the amount of property damage caused by the accidents
has gradually raised. Damaging building structure, fire incidents bring
about not only such property damage but also strength degradation and
member deformation. As a result, the building structure undermines its
structural ability. Examining the degradation and the deformation is
very important because reusing the building is more economical than
reconstruction. Therefore, engineers need to investigate the strength
degradation and member deformation well, and make sure that they
apply right rehabilitation methods. This study aims at evaluating
deformation characteristics of fire damaged and rehabilitated normal
strength concrete beams through both experiments and finite element
analyses. For the experiments, control beams, fire damaged beams and
rehabilitated beams are tested to examine deformation characteristics.
Ten test beam specimens with compressive strength of 21MPa are
fabricated and main test variables are selected as cover thickness of
40mm and 50mm and fire exposure time of 1 hour or 2 hours. After
heating, fire damaged beams are air-recurred for 2 months and
rehabilitated beams are repaired with polymeric cement mortar after
being removed the fire damaged concrete cover. All beam specimens
are tested under four points loading. FE analyses are executed to
investigate the effects of main parameters applied to experimental
study. Test results show that both maximum load and stiffness of the
rehabilitated beams are higher than those of the fire damaged beams.
In addition, predicted structural behaviors from the analyses also show
good rehabilitation effect and the predicted load-deflection curves are
similar to the experimental results. For the further, the proposed
analytical method can be used to predict deformation characteristics of
fire damaged and rehabilitated concrete beams without suffering from
time and cost consuming of experimental process.