Abstract: Bidirectional energy transfer capability with high efficiency and reduced cost is fast gaining prominence in the central part of a lot of power conversion systems in Direct Current (DC) microgrid. Preferably, under the economics constraints, these systems utilise a single high efficiency power electronics conversion system and a dual active bridge converter. In this paper, modeling and performance of Dual Active Bridge (DAB) converter with Extended Phase Shift (EPS) is evaluated with two batteries on both sides of DC bus and bidirectional energy transfer is facilitated and this is further compared with the Single Phase Shift (SPS) mode of operation. Optimum operating zone is identified through exhaustive simulations using MATLAB/Simulink and SimPowerSystem software. Reduced rules based fuzzy logic controller is implemented for closed loop control of DAB converter. The control logic enables the bidirectional energy transfer within the batteries even at lower duty ratios. Charging and discharging of batteries is supervised by the fuzzy logic controller. State of charge, current and voltage for both the batteries are plotted in the battery characteristics. Power characteristics of batteries are also obtained using MATLAB simulations.
Abstract: The stability is an important topic to plan and manage the energy in the microgrids as the same as the conventional power systems. The voltage and frequency stability is one of the most important issues recently studied in microgrids. The objectives of this paper are the modelling and designing of the components and optimal controllers for the voltage and frequency control of the AC/DC hybrid microgrid under the different disturbances. Since the PI controllers have the advantages of simple structure and easy implementation, so they are designed and modeled in this paper. The harmony search (HS) algorithm is used to optimize the controllers’ parameters. According to the achieved results, the PI controllers have a good performance in voltage and frequency control of the microgrid.
Abstract: The application of ESS (Energy Storage Systems) in
the future grids has been the solution of the microgrid. However, high
investment costs necessitate accurate modeling and control strategy of
ESS to justify its economic viability and further underutilization.
Therefore, the reasonable control strategy for ESS which is subjected
to generator and usage helps to curtail the cost of investment and
operation costs. The rated frequency in power system is decreased
when the load is increasing unexpectedly; hence the thermal power is
operated at the capacity of only its 95% for the Governor Free (GF) to
adjust the frequency as reserve (5%) in practice. The ESS can be
utilized with governor at the same time for the frequency response due
to characteristic of its fast response speed and moreover, the cost of
ESS is declined rapidly to the reasonable price. This paper presents the
ESS control strategy to extend usage of the ESS taken account into
governor’s ramp rate and reduce the governor’s intervention as well.
All results in this paper are simulated by MATLAB.
Abstract: There are a number of Distributed Generations (DGs)
installed in microgrid, which may have diverse path and direction of
power flow or fault current. The overcurrent protection scheme for the
traditional radial type distribution system will no longer meet the
needs of microgrid protection. Integrating the Intelligent Electronic
Device (IED) and a Supervisory Control and Data Acquisition
(SCADA) with IEC 61850 communication protocol, the paper
proposes a Microgrid Protection Management System (MPMS) to
protect power system from the fault. In the proposed method, the
MPMS performs logic programming of each IED to coordinate their
tripping sequence. The GOOSE message defined in IEC 61850 is used
as the transmission information medium among IEDs. Moreover, to
cope with the difference in fault current of microgrid between
grid-connected mode and islanded mode, the proposed MPMS applies
the group setting feature of IED to protect system and robust
adaptability. Once the microgrid topology varies, the MPMS will
recalculate the fault current and update the group setting of IED.
Provided there is a fault, IEDs will isolate the fault at once. Finally, the
Matlab/Simulink and Elipse Power Studio software are used to
simulate and demonstrate the feasibility of the proposed method.
Abstract: Microgrids are increasingly being considered to provide electricity for the expanding energy demand in the grid distribution network and grid isolated areas. However, the technical challenges associated with the operation and controls are immense. Management of dynamic power balances, power flow, and network voltage profiles imposes unique challenges in the context of microgrids. Stability of the microgrid during both grid-connected and islanded mode is considered as the major challenge during its operation. Traditional control methods have been employed are based on the assumption of linear loads. For instance the concept of PQ, voltage and frequency control through decoupled PQ are some of very useful when considering linear loads, but they fall short when considering nonlinear loads. The deficiency of traditional control methods of microgrid suggests that more research in the control of microgrids should be done. This research aims at introducing the dq technique concept into decoupled PQ for dynamic load demand control in inverter interfaced DG system operating as isolated LV microgrid. Decoupled PQ in exact mathematical formulation in dq frame is expected to accommodate all variations of the line parameters (resistance and inductance) and to relinquish forced relationship between the DG variables such as power, voltage and frequency in LV microgrids and allow for individual parameter control (frequency and line voltages). This concept is expected to address and achieve accurate control, improve microgrid stability and power quality at all load conditions.