Abstract: Radiant chilled ceiling (RCC) has been perceived to save more energy and provide better thermal comfort than the traditional air conditioning system. However, its application has been rather limited by some reasons e.g., the scarce information about the thermal characteristic in the radiant room and the local climate influence on the system performance, etc. To bridge such gap, an office-like experiment room with a RCC was constructed in the hot and humid climate of Thailand. This paper presents exemplarily results from the RCC experiments to give an insight into the thermal environment in a radiant room and the cooling load associated to maintain the room's comfort condition. It gave a demonstration of the RCC system operation for its application to achieve thermal comfort in offices in a hot humid climate, as well.
Abstract: The concern of the indoor air quality (IAQ) has been increasing due to its risk to human health. The smoking, sweeping, and stove and stovetop use are the activities that have a major contribution to the indoor air pollution. Outdoor air pollution also affects IAQ. The most important factors over IAQ from cooking activities are the materials, fuels, foods, and ventilation. The low-cost, mobile air quality monitoring (LCMAQM) sensors, is reachable technology to assess the IAQ. This is because of the lower cost of LCMAQM compared to conventional instruments. The IAQ was assessed, using LCMAQM, during cooking activities in a University of Minnesota graduate-housing evaluating different ventilation systems. The gases measured are carbon monoxide (CO) and carbon dioxide (CO2). The particles measured are particle matter (PM) 2.5 micrometer (µm) and lung deposited surface area (LDSA). The measurements are being conducted during April 2019 in Como Student Community Cooperative (CSCC) that is a graduate housing at the University of Minnesota. The measurements are conducted using an electric stove for cooking. The amount and type of food and oil using for cooking are the same for each measurement. There are six measurements: two experiments measure air quality without any ventilation, two using an extractor as mechanical ventilation, and two using the extractor and windows open as mechanical and natural ventilation. 3The results of experiments show that natural ventilation is most efficient system to control particles and CO2. The natural ventilation reduces the concentration in 79% for LDSA and 55% for PM2.5, compared to the no ventilation. In the same way, CO2 reduces its concentration in 35%. A well-mixed vessel model was implemented to assess particle the formation and decay rates. Removal rates by the extractor were significantly higher for LDSA, which is dominated by smaller particles, than for PM2.5, but in both cases much lower compared to the natural ventilation. There was significant day to day variation in particle concentrations under nominally identical conditions. This may be related to the fat content of the food. Further research is needed to assess the impact of the fat in food on particle generations.
Abstract: Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause lung cancer and it is not known whether there is a lower limit for when it is not harmful to human beings. Therefore, it is important to reduce the radon concentration as much as possible in buildings. Airtightness is an important factor when dealing with buildings. It is important to avoid air leakages in the building envelope both facing the atmosphere, e.g. in compliance with energy requirements, but also facing the ground, to meet the requirements to ensure and control the indoor environment. Infiltration of air from the ground underneath a building is the main providing source of radon to the indoor air.
Abstract: Ultraviolet photocatalytic oxidation (UV-PCO)
technology has been recommended as a green approach to health
indoor environment when it is integrated into mechanical ventilation
systems for inorganic and organic compounds removal as well as
energy saving due to less outdoor air intakes. Although much research
has been devoted to UV-PCO, limited information is available on the
UV-PCO behavior tested by the mixtures in literature. This project
investigated UV-PCO performance and by-product generation using a
single and a mixture of acetone and MEK at 100 ppb each in a
single-pass duct system in an effort to obtain knowledge associated
with competitive photochemical reactions involved in. The
experiments were performed at 20 % RH, 22 °C, and a gas flow rate of
128 m3/h (75 cfm). Results show that acetone and MEK mutually
reduced each other’s PCO removal efficiency, particularly negative
removal efficiency for acetone. These findings were different from
previous observation of facilitatory effects on the adsorption of
acetone and MEK on photocatalyst surfaces.
Abstract: This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: The exposure to outdoor air pollution causes lung
cancer and increases the risk of bladder cancer. Because air pollution
in urban areas is mainly caused by transportation, it is necessary to
evaluate pollutant exhaust emissions from vehicles during their realworld
use. Nevertheless their evaluation and reduction is a key
problem, especially in the cities, that account for more than 50% of
world population.
A particular attention was given to the slope variability along the
streets during each journey performed by the instrumented vehicle.
In this paper we dealt with the problem of describing a
quantitatively approach for the reconstruction of GPS coordinates and
altitude, in the context of correlation study between driving cycles /
emission / geographical location, during an experimental campaign
realized with some instrumented cars.
Finally the slope analysis can be correlated to the emission and
consumption values in a specific road position, and it could be
evaluated its influence on their behaviour.
Abstract: Microbial air contamination of the outdoor air in Marine Durres-s Harbour (Durres, Albania) was estimated by sedimentation technique in August-October 2008. The sampling areas were: Ferry Terminal (FT), Fishery Harbor (FH), East Zone (EZ), Fuel Quay (FQ) and Apollonian Beach (AB). The aim of this study was to measure the number of aerobic plate count (mesophilic aerobic bacteria) and fungi (yeasts and molds) in the outdoor air in these areas. The number of colonies that were formed determines the number of cells at the moment in the outdoor air; respectively the number of mesophilic aerobic bacteria and yeasts and molds. The measure of bacteria and fungi used is CFU (Colony Forming Units) per Petri dish. It is said that marine harbours are very polluted areas. The aim of study was the definition of mesophilic aerobic bacteria and yeasts and molds number, and the comparison of microorganisms number in air sampling areas.
Abstract: The 'wind-rain' house has a courtyard with glazed
roof, which allows more direct sunlight to come into indoor spaces
during the winter. The glazed roof can be partially opened or closed
and automatically controlled to provide natural ventilation in order to
adjust for indoor thermal conditions and the roof area can be shaded
by reflective insulation materials during the summer. Two field
studies for evaluating indoor thermal conditions of the two 'windrain'
houses have been carried out by author in 2009 and 2010.
Indoor and outdoor air temperature and relative humidity adjacent to
floor and ceiling of the two sample houses were continuously tested
at 15-minute intervals, 24 hours a day during the winter months.
Based on field study data, this study investigates relationships
between building design and indoor thermal condition of the 'windrain'
house to improve the future house design for building thermal
comfort and energy efficiency
Abstract: In this paper is reported an analysis about the outdoor air pollution of the urban centre of the city of Messina. The variations of the most critical pollutants concentrations (PM10, O3, CO, C6H6) and their trends respect of climatic parameters and vehicular traffic have been studied. Linear regressions have been effectuated for representing the relations among the pollutants; the differences between pollutants concentrations on weekend/weekday were also analyzed. In order to evaluate air pollution and its effects on human health, a method for calculating a pollution index was implemented and applied in the urban centre of the city. This index is based on the weighted mean of the most detrimental air pollutants concentrations respect of their limit values for protection of human health. The analyzed data of the polluting substances were collected by the Assessorship of the Environment of the Regional Province of Messina in the year 2004. A statistical analysis of the air quality index trends is also reported.
Abstract: Ventilation is a fundamental requirement for
occupant health and indoor air quality in buildings. Natural
ventilation can be used as a design strategy in free-running
buildings to:
• Renew indoor air with fresh outside air and lower room
temperatures at times when the outdoor air is cooler.
• Promote air flow to cool down the building structure
(structural cooling).
• Promote occupant physiological cooling processes
(comfort cooling).
This paper focuses on ways in which ventilation can
provide the mechanism for heat dissipation and cooling of the
building structure..It also discusses use of ventilation as a
means of increasing air movement to improve comfort when
indoor air temperatures are too high. The main influencing
factors and design considerations and quantitative guidelines
to help meet the design objectives are also discussed.
Abstract: Abstract–Indoor air (VOCs) samples were collected
simultaneously from variety of indoors (e.g. living rooms, baby-s
rooms) and outdoor environments which were voluntarily selected
from the houses in which pregnant residents live throughout Ankara.
This is the first comprehensive study done in Turkey starting from
prenatal period and continued till the babies had one year old. VOCs
levels were measured over 76 homes. Air samples were collected in
Tenax TA sorbent filled tubes with active sampling method and
analyzed with Thermal Desorber and Gas Chromatography/Mass
spectrometry (TD-GC/MS). At the first sampling period in the baby-s
rooms maximum concentration of toluene was measured about
240.77μg.m-3 and in the living rooms maximum concentration of
naphthalene was 180.24μg.m-3. At the second sampling period in the
baby-s rooms maximum concentration of toluene was measured
about 144.97μg.m-3 and in the living rooms maximum concentration
of naphthalene was 247.89μg.m-3. Concentration of TVOCs in the
first period was generally higher than the second period.