Abstract: Air travel, and the use of airports, has experienced proliferative growth in the past few decades, resulting in the concomitant release of air pollutants. Air pollution needs to be monitored because of the known relationship between exposure to air pollutants and increased adverse effects on human health. This study monitored a group of volatile organic compounds (VOCs); specifically BTEX (viz. benzene, toluene, ethyl-benzene and xylenes), as many are detrimental to human health. Through the use of passive sampling methods, the spatial variability of BTEX within an international airport was investigated, in order to determine ‘hotspots’ where occupational exposure to BTEX may be intensified. The passive sampling campaign revealed BTEXtotal concentrations ranged between 12.95–124.04 µg m-3. Furthermore, BTEX concentrations were dispersed heterogeneously within the airport. Due to the slow wind speeds recorded (1.13 m.s-1); the hotspots were located close to their main BTEX sources. The main hotspot was located over the main apron of the airport. Employees working in this area may be chronically exposed to these emissions, which could be potentially detrimental to their health.
Abstract: The catalytic oxidation of CO and volatile organic compounds (VOCs) is considered as one of the most efficient ways to reduce harmful emissions from various chemical industries. The effectiveness of gold-based catalysts for many reactions of environmental significance was proven during the past three decades. The aim of this work was to combine the favorable features of Au and Cu-Ce mixed oxides in the design of new catalytic materials of improved efficiency and economic viability for removal of air pollutants in waste gases from formaldehyde production. Supported oxides of copper and cerium with Cu: Ce molar ratio 2:1 and 1:5 were prepared by wet impregnation of g-alumina. Gold (2 wt.%) catalysts were synthesized by a deposition-precipitation method. Catalysts characterization was carried out by texture measurements, powder X-ray diffraction, temperature programmed reduction and electron paramagnetic resonance spectroscopy. The catalytic activity in the oxidation of CO, CH3OH and (CH3)2O was measured using continuous flow equipment with fixed bed reactor. Both Cu-Ce/alumina samples demonstrated similar catalytic behavior. The addition of gold caused significant enhancement of CO and methanol oxidation activity (100 % degree of CO and CH3OH conversion at about 60 and 140 oC, respectively). The composition of Cu-Ce mixed oxides affected the performance of gold-based samples considerably. Gold catalyst on Cu-Ce/γ-Al2O3 1:5 exhibited higher activity for CO and CH3OH oxidation in comparison with Au on Cu-Ce/γ-Al2O3 2:1. The better performance of Au/Cu-Ce 1:5 was related to the availability of highly dispersed gold particles and copper oxide clusters in close contact with ceria.
Abstract: Group contribution methods such as the UNIFAC are
very useful to researchers and engineers involved in synthesis,
feasibility studies, design and optimization of separation processes.
They can be applied successfully to predict phase equilibrium and
excess properties in the development of chemical and separation
processes. The main focus of this work was to investigate the
possibility of absorbing selected volatile organic compounds (VOCs)
into polydimethylsiloxane (PDMS) using three selected UNIFAC
group contribution methods. Absorption followed by subsequent
stripping is the predominant available abatement technology of
VOCs from flue gases prior to their release into the atmosphere. The
original, modified and effective UNIFAC models were used in this
work. The thirteen selected VOCs that have been considered in this
research are: pentane, hexane, heptanes, trimethylamine, toluene,
xylene, cyclohexane, butyl acetate, diethyl acetate, chloroform,
acetone, ethyl methyl ketone and isobutyl methyl ketone. The
computation was done for solute VOC concentration of 8.55x10-8
which is well in the infinite dilution region. The results obtained in
this study compare very well with those published in literature
obtained through both measurements and predictions. The phase
equilibrium obtained in this study show that PDMS is a good
absorbent for the removal of VOCs from contaminated air streams
through physical absorption.
Abstract: Smoke from domestic wood burning has been
identified as a major contributor to air pollution, motivating detailed
emission measurements under controlled conditions. A series of
experiments was performed to characterise the emissions from wood
combustion in a fireplace and in a woodstove of two common species
of trees grown in Spain: Pyrenean oak (Quercus pyrenaica) and
black poplar (Populus nigra). Volatile organic compounds (VOCs) in
the exhaust emissions were collected in Tedlar bags, re-sampled in
sorbent tubes and analysed by thermal desorption-gas
chromatography-flame ionisation detection. Pyrenean oak presented
substantially higher emissions in the woodstove than in the fireplace,
for the majority of compounds. The opposite was observed for
poplar. Among the 45 identified species, benzene and benzenerelated
compounds represent the most abundant group, followed by
oxygenated VOCs and aliphatics. Emission factors obtained in this
study are generally of the same order than those reported for
residential experiments in the USA.
Abstract: Abstract–Indoor air (VOCs) samples were collected
simultaneously from variety of indoors (e.g. living rooms, baby-s
rooms) and outdoor environments which were voluntarily selected
from the houses in which pregnant residents live throughout Ankara.
This is the first comprehensive study done in Turkey starting from
prenatal period and continued till the babies had one year old. VOCs
levels were measured over 76 homes. Air samples were collected in
Tenax TA sorbent filled tubes with active sampling method and
analyzed with Thermal Desorber and Gas Chromatography/Mass
spectrometry (TD-GC/MS). At the first sampling period in the baby-s
rooms maximum concentration of toluene was measured about
240.77μg.m-3 and in the living rooms maximum concentration of
naphthalene was 180.24μg.m-3. At the second sampling period in the
baby-s rooms maximum concentration of toluene was measured
about 144.97μg.m-3 and in the living rooms maximum concentration
of naphthalene was 247.89μg.m-3. Concentration of TVOCs in the
first period was generally higher than the second period.
Abstract: This work proposes an optical fiber system (OF) for
sensing various volatile organic compounds (VOCs) in human breath
for the diagnosis of some metabolic disorders as a non-invasive
methodology. The analyzed VOCs are alkanes (i.e., ethane, pentane,
heptane, octane, and decane), and aromatic compounds (i.e., benzene,
toluene, and styrene). The OF displays high analytical performance
since it provides near real-time responses, rapid analysis, and low
instrumentation costs, as well as it exhibits useful linear range and
detection limits; the developed OF sensor is also comparable to a
reference methodology (gas chromatography-mass spectrometry) for
the eight tested VOCs.
Abstract: Air emissions from waste treatment plants often
consist of a combination of Volatile Organic Compounds (VOCs)
and odors. Hydrogen sulfide is one of the major odorous gases
present in the waste emissions coming from municipal wastewater
treatment facilities. Hydrogen sulfide (H2S) is odorous, highly toxic
and flammable. Exposure to lower concentrations can result in eye
irritation, a sore throat and cough, shortness of breath, and fluid in
the lungs. Biofiltration has become a widely accepted technology for
treating air streams containing H2S. When compared with other nonbiological
technologies, biofilter is more cost-effective for treating large
volumes of air containing low concentrations of biodegradable compounds.
Optimization of biofilter media is essential for many reasons such as:
providing a higher surface area for biofilm growth, low pressure drop,
physical stability, and good moisture retention. In this work, a novel
biofilter media is developed and tested at a pumping station of a
municipality located in the United Arab Emirates (UAE). The
media is found to be very effective (>99%) in removing H2S
concentrations that are expected in pumping stations under steady
state and shock loading conditions.
Abstract: This paper is a continuation of our interest in the influence of temperature on specific retention volumes and the resulting infinite dilution activity coefficients. This has a direct effect in the design of absorption and stripping columns for the abatement of volatile organic compounds. The interaction of 13 volatile organic compounds (VOCs) with polydimethylsiloxane (PDMS) at varying temperatures was studied by gas liquid chromatography (GLC). Infinite dilution activity coefficients and specific retention volumes obtained in this study were found to be in agreement with those obtained from static headspace and group contribution methods by the authors as well as literature values for similar systems. Temperature variation also allows for transport calculations for different seasons. The results of this work confirm that PDMS is well suited for the scrubbing of VOCs from waste gas streams. Plots of specific retention volumes against temperature gave linear van-t Hoff plots.
Abstract: Group contribution methods such as the UNIFAC are
of major interest to researchers and engineers involved synthesis,
feasibility studies, design and optimization of separation processes as
well as other applications of industrial use. Reliable knowledge of
the phase equilibrium behavior is crucial for the prediction of the fate
of the chemical in the environment and other applications. The
objective of this study was to predict the solubility of selected
volatile organic compounds (VOCs) in glycol polymers and
biodiesel. Measurements can be expensive and time consuming,
hence the need for thermodynamic models. The results obtained in
this study for the infinite dilution activity coefficients compare very
well those published in literature obtained through measurements. It
is suggested that in preliminary design or feasibility studies of
absorption systems for the abatement of volatile organic compounds,
prediction procedures should be implemented while accurate fluid
phase equilibrium data should be obtained from experiment.