Abstract: Diagnosis can be achieved by building a model of a
certain organ under surveillance and comparing it with the real time
physiological measurements taken from the patient. This paper deals
with the presentation of the benefits of using Data Mining techniques
in the computer-aided diagnosis (CAD), focusing on the cancer
detection, in order to help doctors to make optimal decisions quickly
and accurately. In the field of the noninvasive diagnosis techniques,
the endoscopic ultrasound elastography (EUSE) is a recent elasticity
imaging technique, allowing characterizing the difference between
malignant and benign tumors. Digitalizing and summarizing the main
EUSE sample movies features in a vector form concern with the use
of the exploratory data analysis (EDA). Neural networks are then
trained on the corresponding EUSE sample movies vector input in
such a way that these intelligent systems are able to offer a very
precise and objective diagnosis, discriminating between benign and
malignant tumors. A concrete application of these Data Mining
techniques illustrates the suitability and the reliability of this
methodology in CAD.
Abstract: Biochemical Oxygen Demand (BOD) is a measure of
the oxygen used in bacteria mediated oxidation of organic substances
in water and wastewater. Theoretically an infinite time is required for
complete biochemical oxidation of organic matter, but the
measurement is made over 5-days at 20 0C or 3-days at 27 0C test
period with or without dilution. Researchers have worked to further
reduce the time of measurement.
The objective of this paper is to review advancement made in
BOD measurement primarily to minimize the time and negate the
measurement difficulties. Survey of literature review in four such
techniques namely BOD-BARTTM, Biosensors, Ferricyanidemediated
approach, luminous bacterial immobilized chip method.
Basic principle, method of determination, data validation and their
advantage and disadvantages have been incorporated of each of the
methods.
In the BOD-BARTTM method the time lag is calculated for the
system to change from oxidative to reductive state. BIOSENSORS
are the biological sensing element with a transducer which produces
a signal proportional to the analyte concentration. Microbial species
has its metabolic deficiencies. Co-immobilization of bacteria using
sol-gel biosensor increases the range of substrate. In ferricyanidemediated
approach, ferricyanide has been used as e-acceptor instead
of oxygen. In Luminous bacterial cells-immobilized chip method,
bacterial bioluminescence which is caused by lux genes was
observed. Physiological responses is measured and correlated to
BOD due to reduction or emission.
There is a scope to further probe into the rapid estimation of BOD.
Abstract: Hepatocellular carcinoma, also called hepatoma, most
commonly appears in a patient with chronic viral hepatitis. In
patients with a higher suspicion of HCC, such as small or subtle
rising of serum enzymes levels, the best method of diagnosis
involves a CT scan of the abdomen, but only at high cost. The aim of
this study was to increase the ability of the physician to early detect
HCC, using a probabilistic neural network-based approach, in order
to save time and hospital resources.
Abstract: Deployment of pneumatic muscles in various
industrial applications is still in its early days, considering the relative
newness of these components. The field of robotics holds particular
future potential for pneumatic muscles, especially in view of their
specific behaviour known as compliance. The paper presents and
discusses an innovative constructive solution for a gripper system
mountable on an industrial robot, based on actuation by a linear
pneumatic muscle and transmission of motion by gear and rack
mechanism. The structural, operational and constructive models of
the new gripper are presented, along with some of the experimental
results obtained subsequently to the testing of a prototype. Further
presented are two control variants of the gripper system, one by
means of a 3/2-way fast-switching solenoid valve, the other by means
of a proportional pressure regulator. Advantages and disadvantages
are discussed for both variants.
Abstract: The crystalline quality of the AlGaN/GaN high electron mobility transistor (HEMT) structure grown on a 200 mm silicon substrate has been investigated using UV-visible micro- Raman scattering and photoluminescence (PL). The visible Raman scattering probes the whole nitride stack with the Si substrate and shows the presence of a small component of residual in-plane stress in the thick GaN buffer resulting from a wafer bowing, while the UV micro-Raman indicates a tensile interfacial stress induced at the top GaN/AlGaN/AlN layers. PL shows a good crystal quality GaN channel where the yellow band intensity is very low compared to that of the near-band-edge transition. The uniformity of this sample is shown by measurements from several points across the epiwafer.
Abstract: Visualizing sound and noise often help us to determine
an appropriate control over the source localization. Near-field acoustic
holography (NAH) is a powerful tool for the ill-posed problem.
However, in practice, due to the small finite aperture size, the discrete
Fourier transform, FFT based NAH couldn-t predict the activeregion-
of-interest (AROI) over the edges of the plane. Theoretically
few approaches were proposed for solving finite aperture problem.
However most of these methods are not quite compatible for the
practical implementation, especially near the edge of the source. In
this paper, a zip-stuffing extrapolation approach has suggested with
2D Kaiser window. It is operated on wavenumber complex space
to localize the predicted sources. We numerically form a practice
environment with touch impact databases to test the localization of
sound source. It is observed that zip-stuffing aperture extrapolation
and 2D window with evanescent components provide more accuracy
especially in the small aperture and its derivatives.
Abstract: Manufacturing processes demand tight dimensional
tolerances. The paper concerns a transducer for precise measurement
of displacement, based on a camera containing a linescan chip.
When tests were conducted using a track of black and white stripes
with a 2mm pitch, errors in measuring on individual cycle amounted
to 1.75%, suggesting that a precision of 35 microns is achievable.
Abstract: The purpose of this study is to present a non invasive
method for the marginal adaptation evaluation in class V composite
restorations. Standardized class V cavities, prepared in human
extracted teeth, were filled with Premise (Kerr) composite. The
specimens were thermo cycled. The interfaces were examined by
Optical Coherence Tomography method (OCT) combined with the
confocal microscopy and fluorescence. The optical configuration
uses two single mode directional couplers with a superluminiscent
diode as the source at 1300 nm. The scanning procedure is similar to
that used in any confocal microscope, where the fast scanning is enface
(line rate) and the depth scanning is much slower (at the frame
rate). Gaps at the interfaces as well as inside the composite resin
materials were identified. OCT has numerous advantages which
justify its use in vivo as well as in vitro in comparison with
conventional techniques.
Abstract: Construction of portable device for fast analysis of energetic materials is described in this paper. The developed analytical system consists of two main parts: a miniaturized microcolumn liquid chromatograph of unique construction and original chemiluminescence detector. This novel portable device is able to determine selectively most of nitramine- and nitroester-based explosives as well as inorganic nitrates at trace concentrations in water or soil extracts in less than 8 minutes.
Abstract: Post growth annealing of solution grown ZnO
nanowire array is performed under controlled oxygen ambience. The
role of annealing over surface defects and their consequence on
dark/photo-conductivity and photosensitivity of nanowire array is
investigated. Surface defect properties are explored using various
measurement tools such as contact angle, photoluminescence, Raman
spectroscopy and XPS measurements. The contact angle of the NW
films reduces due to oxygen annealing and nanowire film surface
changes from hydrophobic (96°) to hydrophilic (16°). Raman and
XPS spectroscopy reveal that oxygen annealing improves the crystal
quality of the nanowire films. The defect band emission intensity
(relative to band edge emission, ID/IUV) reduces from 1.3 to 0.2 after
annealing at 600 °C at 10 SCCM flow of oxygen. An order
enhancement in dark conductivity is observed in O2 annealed
samples, while photoconductivity is found to be slightly reduced due
to lower concentration of surface related oxygen defects.
Abstract: Fabrication and efficiency enhancement of non-mercury, high efficiency and green field emission lamps using carbon nano-materials such as carbon nanotubes as cathode field emitters was studied. Phosphor was coated on the ITO glass or metal substrates as the anode. The luminescence efficiency enhancement was carried out by upgrading the uniform of the emitters, improving electron and thermal conductivity of the phosphor and the optimization of the design of different cathode/anode configurations. After evaluation of the aforementioned parameters, the luminescence efficiency of the field emission lamps was raised.
Abstract: The photoluminescence (PL) at 1.55 μm from
semiconducting β-FeSi2 has attracted a noticeable interest for
silicon-based optoelectronic applications. Moreover, its high optical
absorption coefficient (higher than 105 cm-1 above 1.0 eV) allows this
semiconducting material to be used as photovoltanics devices.
A clear PL spectrum for β-FeSi2 was observed by Cu or Au coating
on Si(001). High-crystal-quality β-FeSi2 with a low-level nonradiative
center was formed on a Cu- or Au- reated Si layer. This method of
deposition can be applied to other materials requiring high crystal
quality.
Abstract: Erroneous computer entry problems [here: 'e'errors] in hospital labs threaten the patients-–health carers- relationship, undermining the health system credibility. Are e-errors random, and do lab professionals make them accidentally, or may they be traced through meaningful determinants? Theories on internal causality of mistakes compel to seek specific causal ascriptions of hospital lab eerrors instead of accepting some inescapability. Undeniably, 'To Err is Human'. But in view of rapid global health organizational changes, e-errors are too expensive to lack in-depth considerations. Yet, that efunction might supposedly be entrenched in the health carers- job description remains under dispute – at least for Hellenic labs, where e-use falls behind generalized(able) appreciation and application. In this study: i) an empirical basis of a truly high annual cost of e-errors at about €498,000.00 per rural Hellenic hospital was established, hence interest in exploring the issue was sufficiently substantiated; ii) a sample of 270 lab-expert nurses, technicians and doctors were assessed on several personality, burnout and e-error measures, and iii) the hypothesis that the Hardiness vs Alienation personality construct disposition explains resistance vs proclivity to e-errors was tested and verified: Hardiness operates as a resilience source in the encounter of high pressures experienced in the hospital lab, whereas its 'opposite', i.e., Alienation, functions as a predictor, not only of making e-errors, but also of leading to burn-out. Implications for apt interventions are discussed.
Abstract: The effect of chemical treatment in CdCl2 and thermal
annealing in 400°C, on the defect structures of potentially useful
ZnS\CdS solar cell thin films deposited onto quartz substrate and
prepared by vacuum deposition method was studied using the
Thermoluminesence (TL) techniques. A series of electron and hole
traps are found in the various deposited samples studied. After
annealing, however, it was observed that the intensity and activation
energy of TL signal increases with loss of the low temperature
electron traps.
Abstract: Bonding has become a routine procedure in several
dental specialties – from prosthodontics to conservative dentistry and
even orthodontics. In many of these fields it is important to be able to
investigate the bonded interfaces to assess their quality. All currently
employed investigative methods are invasive, meaning that samples
are destroyed in the testing procedure and cannot be used again. We
have investigated the interface between human enamel and bonded
ceramic brackets non-invasively, introducing a combination of new
investigative methods – optical coherence tomography (OCT),
fluorescence OCT and confocal microscopy (CM). Brackets were
conventionally bonded on conditioned buccal surfaces of teeth. The
bonding was assessed using these methods. Three dimensional
reconstructions of the detected material defects were developed using
manual and semi-automatic segmentation. The results clearly prove
that OCT, fluorescence OCT and CM are useful in orthodontic
bonding investigations.
Abstract: In the present work, an attempt is made to understand
electromagnetic field confinement in a subwavelength waveguide
structure using concepts of quantum mechanics. Evanescent field in
the waveguide is looked as inability of the photon to get confined in
the waveguide core and uncertainty of position is assigned to it. The
momentum uncertainty is calculated from position uncertainty.
Schrödinger wave equation for the photon is written by incorporating
position-momentum uncertainty. The equation is solved and field
distribution in the waveguide is obtained. The field distribution and
power confinement is compared with conventional waveguide theory.
They were found in good agreement with each other.
Abstract: The Programmable Logic Controller (PLC) plays a
vital role in automation and process control. Grafcet is used for
representing the control logic, and traditional programming
languages are used for describing the pure algorithms. Grafcet is used
for dividing the process to be automated in elementary sequences that
can be easily implemented. Each sequence represent a step that has
associated actions programmed using textual or graphical languages
after case. The programming task is simplified by using a set of
subroutines that are used in several steps. The paper presents an
example of implementation for a punching machine for sheets and
plates. The use the graphical languages the programming of a
complex sequential process is a necessary solution. The state of
Grafcet can be used for debugging and malfunction determination.
The use of the method combined with a set of knowledge acquisition
for process application reduces the downtime of the machine and
improve the productivity.
Abstract: Effect of viscosity of media on kinetic parameters of the coupled enzyme system NADH:FMN-oxidoreductase–luciferase was investigated with addition of organic solvents (glycerol and sucrose), because bioluminescent enzyme systems based on bacterial luciferases offer a unique and general tool for analysis of the many analytes and enzymes in the environment, research and clinical laboratories and other fields. The possibility of stabilization and increase of activity of the coupled enzyme system NADH:FMN-oxidoreductase–luciferase activity in vicious aqueous-organic mixtures have been shown.
Abstract: METIS is the Multi Element Telescope for Imaging
and Spectroscopy, a Coronagraph aboard the European Space
Agency-s Solar Orbiter Mission aimed at the observation of the solar
corona via both VIS and UV/EUV narrow-band imaging and spectroscopy. METIS, with its multi-wavelength capabilities, will
study in detail the physical processes responsible for the corona heating and the origin and properties of the slow and fast solar wind.
METIS electronics will collect and process scientific data thanks to its detectors proximity electronics, the digital front-end subsystem
electronics and the MPPU, the Main Power and Processing Unit,
hosting a space-qualified processor, memories and some rad-hard
FPGAs acting as digital controllers.This paper reports on the overall
METIS electronics architecture and data processing capabilities
conceived to address all the scientific issues as a trade-off solution between requirements and allocated resources, just before the
Preliminary Design Review as an ESA milestone in April 2012.
Abstract: The influence of human activities produced by dams
along the river beds is minor, but the location of accumulation of
water directly influences the hydrological regime. The most
important effect of the influence of damming on the way water flows
decreases the frequency of floods. The water rate controls the water
flow of the dams. These natural reservoirs become dysfunctional and,
as a result, a new distribution of flow in the downstream sector,
where maximum flow is, brings about, in this case, higher values. In
addition to fishing, middle and lower courses of rivers located by
accumulation also have a role in mitigating flood waves, thus
providing flood protection. The Vaslui also ensures a good part of the
needs of the town water supply. The most important lake is Solesti,
close to the Vaslui River, opened in 1974. A hydrological regime of
accumulation is related to an anthropogenic and natural drainage
system. The design conditions and their manoeuvres drain or fill the
water courses.