Abstract: Here, we study the characteristic feature of
conventional (ON-OFF keying) and soliton based transmission
system. We consider 20Gbps transmission system implemented with
Conventional Single Mode Fiber (C-SMF) to examine the role of
Gaussian pulse which is the characteristic of conventional
propagation and Hyperbolic-secant pulse which is the characteristic
of soliton propagation in it. We note the influence of these pulses
with respect to different dispersion lengths and soliton period in
conventional and soliton system respectively and evaluate the system
performance in terms of Quality factor. From the analysis, we could
prove that the soliton pulse has the consistent performance even for
long distance without dispersion compensation than the conventional
system as it is robust to dispersion. For the length of transmission of
200Km, soliton system yielded Q of 33.958 while the conventional
system totally exhausted with Q=0.
Abstract: Due to the continuous increment of the load demand,
identification of weaker buses, improvement of voltage profile and
power losses in the context of the voltage stability problems has
become one of the major concerns for the larger, complex,
interconnected power systems. The objective of this paper is to
review the impact of Flexible AC Transmission System (FACTS)
controller in Wind generators connected electrical network for
maintaining voltage stability. Wind energy could be the growing
renewable energy due to several advantages. The influence of wind
generators on power quality is a significant issue; non uniform power
production causes variations in system voltage and frequency.
Therefore, wind farm requires high reactive power compensation; the
advances in high power semiconducting devices have led to the
development of FACTS. The FACTS devices such as for example
SVC inject reactive power into the system which helps in maintaining
a better voltage profile. The performance is evaluated on an IEEE 14
bus system, two wind generators are connected at low voltage buses
to meet the increased load demand and SVC devices are integrated at
the buses with wind generators to keep voltage stability. Power
flows, nodal voltage magnitudes and angles of the power network are
obtained by iterative solutions using MIPOWER.
Abstract: One of the key aspects of power quality improvement
in power system is the mitigation of voltage sags/swells and flicker.
Custom power devices have been known as the best tools for voltage
disturbances mitigation as well as reactive power compensation.
Dynamic Voltage Restorer (DVR) which is the most efficient and
effective modern custom power device can provide the most
commercial solution to solve several problems of power quality in
distribution networks. This paper deals with analysis and simulation
technique of DVR based on instantaneous power theory which is a
quick control to detect signals. The main purpose of this work is to
remove three important disturbances including voltage sags/swells
and flicker. Simulation of the proposed method was carried out on
two sample systems by using Matlab software environment and the
results of simulation show that the proposed method is able to
provide desirable power quality in the presence of wide range of
disturbances.
Abstract: Power systems are operating under stressed condition
due to continuous increase in demand of load. This can lead to
voltage instability problem when face additional load increase or
contingency. In order to avoid voltage instability suitable size of
reactive power compensation at optimal location in the system is
required which improves the load margin. This work aims at
obtaining optimal size as well as location of compensation in the 39-
bus New England system with the help of Bacteria Foraging and
Genetic algorithms. To reduce the computational time the work
identifies weak candidate buses in the system, and then picks only
two of them to take part in the optimization. The objective function is
based on a recently proposed voltage stability index which takes into
account the weighted average sensitivity index is a simpler and faster
approach than the conventional CPF algorithm. BFOA has been
found to give better results compared to GA.
Abstract: The 3D body movement signals captured during
human-human conversation include clues not only to the content of
people’s communication but also to their culture and personality.
This paper is concerned with automatic extraction of this information
from body movement signals. For the purpose of this research, we
collected a novel corpus from 27 subjects, arranged them into groups
according to their culture. We arranged each group into pairs and
each pair communicated with each other about different topics.
A state-of-art recognition system is applied to the problems of
person, culture, and topic recognition. We borrowed modeling,
classification, and normalization techniques from speech recognition.
We used Gaussian Mixture Modeling (GMM) as the main technique
for building our three systems, obtaining 77.78%, 55.47%, and
39.06% from the person, culture, and topic recognition systems
respectively. In addition, we combined the above GMM systems with
Support Vector Machines (SVM) to obtain 85.42%, 62.50%, and
40.63% accuracy for person, culture, and topic recognition
respectively.
Although direct comparison among these three recognition
systems is difficult, it seems that our person recognition system
performs best for both GMM and GMM-SVM, suggesting that intersubject
differences (i.e. subject’s personality traits) are a major
source of variation. When removing these traits from culture and
topic recognition systems using the Nuisance Attribute Projection
(NAP) and the Intersession Variability Compensation (ISVC)
techniques, we obtained 73.44% and 46.09% accuracy from culture
and topic recognition systems respectively.
Abstract: Nowadays, Photovoltaic-PV Farms/ Parks and large
PV-Smart Grid Interface Schemes are emerging and commonly
utilized in Renewable Energy distributed generation. However, PVhybrid-
Dc-Ac Schemes using interface power electronic converters
usually has negative impact on power quality and stabilization of
modern electrical network under load excursions and network fault
conditions in smart grid. Consequently, robust FACTS based
interface schemes are required to ensure efficient energy utilization
and stabilization of bus voltages as well as limiting switching/fault
onrush current condition. FACTS devices are also used in smart grid-
Battery Interface and Storage Schemes with PV-Battery Storage
hybrid systems as an elegant alternative to renewable energy
utilization with backup battery storage for electric utility energy and
demand side management to provide needed energy and power
capacity under heavy load conditions. The paper presents a robust
interface PV-Li-Ion Battery Storage Interface Scheme for
Distribution/Utilization Low Voltage Interface using FACTS
stabilization enhancement and dynamic maximum PV power tracking
controllers.
Digital simulation and validation of the proposed scheme is done
using MATLAB/Simulink software environment for Low Voltage-
Distribution/Utilization system feeding a hybrid Linear-Motorized
inrush and nonlinear type loads from a DC-AC Interface VSC-6-
pulse Inverter Fed from the PV Park/Farm with a back-up Li-Ion
Storage Battery.
Abstract: In this paper a novel design of aerostatic thrust bearing
is proposed and is analyzed numerically. The capillary restrictor and
bearing disk are made of elastomer like silicone and PU. The
viscoelasticity of elastomer helps the capillary expand for more air
flux and at the same time, allows conicity of the bearing surface to
form when the air pressure is enhanced. Therefore the bearing has the
better ability of passive compensation. In the present example, as
compared with the typical model, the new designs can nearly double
the load capability and offer four times static stiffness.
Abstract: This paper presents a study on Proportional Resonant
(PR) current control with additional PR harmonic compensators for
Grid Connected Photovoltaic (PV) Inverters. Both simulation and
experimental results will be presented. Testing was carried out on a
3kW Grid-Connected PV Inverter which was designed and
constructed for this research.
Abstract: Anultra-low power capacitor less low-dropout voltage
regulator with improved transient response using gain enhanced feed
forward path compensation is presented in this paper. It is based on a
cascade of a voltage amplifier and a transconductor stage in the feed
forward path with regular error amplifier to form a composite gainenhanced
feed forward stage. It broadens the gain bandwidth and thus
improves the transient response without substantial increase in power
consumption. The proposed LDO, designed for a maximum output
current of 100 mA in UMC 180 nm, requires a quiescent current of
69 )A. An undershot of 153.79mV for a load current changes from
0mA to 100mA and an overshoot of 196.24mV for current change of
100mA to 0mA. The settling time is approximately 1.1 )s for the
output voltage undershooting case. The load regulation is of 2.77
)V/mA at load current of 100mA. Reference voltage is generated by
using an accurate band gap reference circuit of 0.8V.The costly
features of SOC such as total chip area and power consumption is
drastically reduced by the use of only a total compensation
capacitance of 6pF while consuming power consumption of 0.096
mW.
Abstract: In many communication and signal processing
systems, it is highly desirable to implement an efficient narrow-band
filter that decimate or interpolate the incoming signals. This paper
presents hardware efficient compensated CIC filter over a narrow
band frequency that increases the speed of down sampling by using
multiplierless decimation filters with polyphase FIR filter structure.
The proposed work analyzed the performance of compensated CIC
filter on the bases of the improvement of frequency response with
reduced hardware complexity in terms of no. of adders and
multipliers and produces the filtered results without any alterations.
CIC compensator filter demonstrated that by using compensation
with CIC filter improve the frequency response in passed of interest
26.57% with the reduction in hardware complexity 12.25%
multiplications per input sample (MPIS) and 23.4% additions per
input sample (APIS) w.r.t. FIR filter respectively.
Abstract: Static VAR System (SVS) is a kind of FACTS device which is used in power system primarily for the purpose of voltage and reactive power control. In this paper presents a systematic approach for designing SVS supplementary controller, which is used to improve the damping of power system oscillation. The combined bus voltage and line current (CBVLC) supplementary controller has been developed and incorporated in the SVS control system located at the middle of the series compensated long transmission line. Damping of torsional stresses due to subsynchronous resonance resulting from series capacitive compensation using CBVLC is investigated in this paper. Simulation results are carried out with MATLAB/Simulink on the IEEE first benchmark model (FBM). The simulation results show that the oscillations are satisfactorily damped out by the SVS supplementary controller. Time domain simulation is performed on power system and the results demonstrate the effectiveness of the proposed controller.
Abstract: The objectives were to study language learning strategies (LLSs) employed by Chinese students, and the frequency of LLSs they used, and examine the relationship between the use of LLSs and gender. The Strategy Inventory for Language Learning (SILL) by Oxford was administered to thirty-six Chinese students at Suan Sunandha Rajabhat University in Thailand. The data obtained was analyzed using descriptive statistics and chi-square tests. Three useful findings were found on the use of LLSs reported by Chinese students. First, Chinese students used overall LLSs at a high level. Second, among the six strategy groups, Chinese students employed compensation strategy most frequently and memory strategy least frequently. Third, the research results also revealed that gender had significant effect on Chinese Student’s use of overall LLSs.
Abstract: In the last few years, harmonics have been occurred
with the increasing use of nonlinear loads, and these harmonics have
been an ever increasing problem for the line systems. This situation
importantly affects the quality of power and gives large losses to the
network. An efficient way to solve these problems is providing
harmonic compensation through parallel active power filters. Many
methods can be used in the control systems of the parallel active
power filters which provide the compensation. These methods
efficiently affect the performance of the active power filters. For this
reason, the chosen control method is significant. In this study, Fourier
analysis (FA) control method and synchronous reference frame (SRF)
control method are discussed. These control methods are designed for
both eliminate harmonics and perform reactive power compensation
in MATLAB/Simulink pack program and are tested. The results have
been compared for each two methods.
Abstract: The application of today's semiconductor transistors in high power UHF DVB-T linear amplifiers has evolved significantly by utilizing LDMOS technology. This fact provides engineers with the option to design a single transistor signal amplifier which enables output power and linearity that was unobtainable previously using bipolar junction transistors or later type first generation MOSFETS. The quiescent current stability in terms of thermal variations of the LDMOS guarantees a robust operation in any topology of DVB-T signal amplifiers. Otherwise, progressively uncontrolled heat dissipation enhancement on the LDMOS case can degrade the amplifier’s crucial parameters in regards to the gain, linearity and RF stability, resulting in dysfunctional operation or a total destruction of the unit. This paper presents one more sophisticated approach from the traditional biasing circuits used so far in LDMOS DVB-T amplifiers. It utilizes a microprocessor control technology, providing stability in topologies where IDQ must be perfectly accurate.
Abstract: Unwanted side effects because of spectral aliasing and spectral imaging during signal processing would be the major concern over the sampling rate alteration. Multirate-multistage implementation of digital filter could come about a large computational saving than single rate filter suitable for sample rate conversion. This implementation can further improve through high-level architectural transformation in circuit level. Reallocating registers and relocating flip-flops across logic gates through retiming certainly a prominent sequential transformation technology, that optimize hardware circuits to achieve faster clocking speed without affecting the functionality. In this paper, we proposed an efficient compensated cascade Integrator comb (CIC) decimation filter structure that analyze the consequence of filter order variation which has a retimed FIR filter being compensator while using the cutset retiming technique and achieved an improvement in the passband droop by 14% to 39%, in computation time by 38.04%, 25.78%, 12.21%, 6.69% and 4.44% and reduction in path delay by 62.27%, 72%, 86.63%, 91.56% and 94.42% of 3, 6, 8, 12 and 24 order filter respectively than the non-retimed CIC compensation filter.
Abstract: Nowadays the growth of distributed generation within the bulk power system is feasible by using the optimal control of the transmission lines power flow. Static Synchronous Compensators (STATCOM) is effective for improving voltage stability but it can only exchange reactive power with the power grid. The integration of Superconducting Magnetic Energy Storage (SMES) with a STATCOM can extend the traditional STATCOM capabilities to four-quadrant bulk power system power flow control and providing exchange both the active and reactive power related to the STATCOM with the ac network. This paper shows how the SMES system can be connected to the ac system via the DC bus of a STATCOM and also analyzes how the integration of STATCOM and SMES allows the bus voltage regulation and power oscillation damping (POD) to be achieved simultaneously. The dynamic performance of the integrated STATCOM-SMES is evaluated through simulation by using PSCAD/EMTDC software and the compensation effectiveness of this integrated compensator is shown.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.
Abstract: One of the major power quality concerns in modern times is the problem of current harmonics. The current harmonics is caused due to the increase in non-linear loads which is largely dominated by power electronics devices. The Shunt active filtering is one of the best solutions for mitigating current harmonics. This paper describes a fuzzy logic controller based (FLC) based three Phase Shunt active Filter to achieve low current harmonic distortion (THD) and Reactive power compensation. The performance of fuzzy logic controller is analysed under both balanced sinusoidal and unbalanced sinusoidal source condition. The above controller serves the purpose of maintaining DC Capacitor Voltage constant. The proposed shunt active filter uses hysteresis current controller for current control of IGBT based PWM inverter. The simulation results of model in Simulink MATLAB reveals satisfying results.
Abstract: Five-axis computer numerical control (CNC) machine tools (three linear and two rotary axes) are ideally suited to the fabrication of complex work pieces, such as dies, turbo blades, and cams. The locations of the axis average line and centerline of the rotary axes strongly influence the performance of these machines; however, techniques to compensate for eccentric error in the rotary axes remain weak. This paper proposes optical (Non-Bar) techniques capable of calibrating five-axis CNC machine tools and compensating for eccentric error in the rotary axes. This approach employs the measurement path in ISO/CD 10791-6 to determine the eccentric error in two rotary axes, for which compensatory measures can be implemented. Experimental results demonstrate that the proposed techniques can improve the performance of various five-axis CNC machine tools by more than 90%. Finally, a result of the cutting test using a B-type five-axis CNC machine tool confirmed to the usefulness of this proposed compensation technique.
Abstract: In this paper feedforward controller is designed to eliminate nonlinear hysteresis behaviors of a piezoelectric stack actuator (PSA) driven system. The control design is based on inverse Prandtl-Ishlinskii (P-I) hysteresis model identified using particle swarm optimization (PSO) technique. Based on the identified P-I model, both the inverse P-I hysteresis model and feedforward controller can be determined. Experimental results obtained using the inverse P-I feedforward control are compared with their counterparts using hysteresis estimates obtained from the identified Bouc-Wen model. Effectiveness of the proposed feedforward control scheme is demonstrated. To improve control performance feedback compensation using traditional PID scheme is adopted to integrate with the feedforward controller.