Abstract: The purpose of this study was to reduce patient
waiting times, improve system throughput and improve resources
utilization in radiology department. A discrete event simulation
model was developed using Arena simulation software to investigate
different alternatives to improve the overall system delivery based on
adding resource scenarios due to the linkage between patient waiting
times and resource availability. The study revealed that there is no
addition investment need to procure additional scanner but hospital
management deploy managerial tactics to enhance machine
utilization and reduce the long waiting time in the department.
Abstract: Metallic foams have good potential for lightweight
structures for impact and blast mitigation. Therefore it is important to
find out the optimized foam structure (i.e. cell size, shape, relative
density, and distribution) to maximise energy absorption. In this
paper, quasistatic compression and microstructural characterization
of closed-cell aluminium foams of different pore size and cell
distributions have been carried out. We present results for two
different aluminium metal foams of density 0.49-0.51 g/cc and 0.31-
0.34 g/cc respectively that have been tested in quasi-static
compression. The influence of cell geometry and cell topology on
quasistatic compression behaviour has been investigated using optical
microscope and computed tomography (micro-CT) analysis. It is
shown that the deformation is not uniform in the structure and
collapse begins at the weakest point.
Abstract: Medical imaging technology has experienced a
dramatic change in the last few years. Medical imaging refers to the
techniques and processes used to create images of the human body
(or parts thereof) for various clinical purposes such as medical
procedures and diagnosis or medical science including the study of
normal anatomy and function. With the growth of computers and
image technology, medical imaging has greatly influenced the
medical field. The diagnosis of a health problem is now highly
dependent on the quality and the credibility of the image analysis.
This paper deals with the various aspects and types of medical
imaging.
Abstract: The study area is Zaria, located in the basement
complex of northern Nigeria. The rock type forming the major part of
the Zaria batholith is granite. This research work was carried out to
compare the responses of seismic refraction tomography and
resistivity tomography in the same geologic environment and under
the same conditions. Hence, the choice of the site that has a visible
granitic outcrop that extends across a narrow stream channel and is
flanked by unconsolidated overburden, a neutral profile that was
covered by plain overburden and a site with thick lateritic cover
became necessary. The results of the seismic and resistivity
tomography models reveals that seismic velocity and resistivity does
not always simultaneously increase with depth, but their responses in
any geologic environment are determined by changes in the
mechanical and chemical content of the rock types rather than depth.
Abstract: An accurate study of blood flow is associated with an accurate vascular pattern and geometrical properties of the organ of interest. Due to the complexity of vascular networks and poor accessibility in vivo, it is challenging to reconstruct the entire vasculature of any organ experimentally. The objective of this study is to introduce an innovative approach for the reconstruction of a full vascular tree from available morphometric data. Our method consists of implementing morphometric data on those parts of the vascular tree that are smaller than the resolution of medical imaging methods. This technique reconstructs the entire arterial tree down to the capillaries. Vessels greater than 2 mm are obtained from direct volume and surface analysis using contrast enhanced computed tomography (CT). Vessels smaller than 2mm are reconstructed from available morphometric and distensibility data and rearranged by applying Murray’s Laws. Implementation of morphometric data to reconstruct the branching pattern and applying Murray’s Laws to every vessel bifurcation simultaneously, lead to an accurate vascular tree reconstruction. The reconstruction algorithm generates full arterial tree topography down to the first capillary bifurcation. Geometry of each order of the vascular tree is generated separately to minimize the construction and simulation time. The node-to-node connectivity along with the diameter and length of every vessel segment is established and order numbers, according to the diameter-defined Strahler system, are assigned. During the simulation, we used the averaged flow rate for each order to predict the pressure drop and once the pressure drop is predicted, the flow rate is corrected to match the computed pressure drop for each vessel. The final results for 3 cardiac cycles is presented and compared to the clinical data.
Abstract: This paper considers the NP-hard problem of reconstructing binary matrices satisfying exactly-1-4-adjacency constraint from its row and column projections. This problem is formulated into a maximization problem. The objective function gives a measure of adjacency constraint for the binary matrices. The maximization problem is solved by the simulated annealing algorithm and experimental results are presented.
Abstract: Occurrence of popcorn in IC packages while assembling them onto the PCB is a well known moisture sensitive reliability issues, especially for surface mount packages. Commonly reflow soldering simulation process is conducted to assess the impact of assembling IC package onto PCB. A strain gauge-based instrumentation is developed to investigate the popcorn effect in surface mount packages during reflow soldering process. The instrument is capable of providing real-time quantitative information of the occurrence popcorn phenomenon in IC packages. It is found that the popcorn occur temperatures between 218 to 241°C depending on moisture soak condition, but not at the peak temperature of the reflow process. The presence of popcorn and delamination are further confirmed by scanning acoustic tomography as a failure analysis.
Abstract: The objective of this paper is to develop a computational model of human nasal cavity from computed tomography (CT) scans using MIMICS software. Computational fluid dynamic techniques were employed to understand nasal airflow. Gambit and Fluent software was used to perform CFD simulation. Velocity profiles, iteration plots, pressure distribution, streamline and pathline patterns for steady, laminar airflow inside the human nasal cavity of healthy and also infected persons are presented in detail. The implications for olfaction are visualized. Results are validated with the available numerical and experimental data. The graphs reveal that airflow varies with different anatomical nasal structures and only fraction of the inspired air reaches the olfactory region. The Deviations in the results suggest that the treatment of infected volunteers will improve the olfactory function.
Abstract: In this paper problem of edge detection in digital images is considered. Edge detection based on morphological operators was applied on two sets (brain & chest) ct images. Three methods of edge detection by applying line morphological filters with multi structures in different directions have been used. 3x3 filter for first method, 5x5 filter for second method, and 7x7 filter for third method. We had applied this algorithm on (13 images) under MATLAB program environment. In order to evaluate the performance of the above mentioned edge detection algorithms, standard deviation (SD) and peak signal to noise ratio (PSNR) were used for justification for all different ct images. The objective method and the comparison of different methods of edge detection, shows that high values of both standard deviation and PSNR values of edge detection images were obtained.
Abstract: A silicon photomultiplier (SiPM) was designed, fabricated and characterized. The SiPM was based on SACM (Separation of Absorption, Charge and Multiplication) structure, which was optimized for blue light detection in application of positron emission tomography (PET). The achieved SiPM array has a high geometric fill factor of 64% and a low breakdown voltage of about 22V, while the temperature dependence of breakdown voltage is only 17mV/°C. The gain and photon detection efficiency of the device achieved were also measured under illumination of light at 405nm and 460nm wavelengths. The gain of the device is in the order of 106. The photon detection efficiency up to 60% has been observed under 1.8V overvoltage.
Abstract: In this study, we present a new and fast algorithm for lung segmentation using CTA images. This process is quite important especially at lung vessel segmentation, detection of pulmonary emboly, finding nodules or segmentation of airways. Applied method has been carried out at four steps. At first step, images have been applied optimal threshold. At the second one, the subsegment vessels, which have a place in lung region and which are in small dimension, have been removed. At the third one, identifying and segmentation of lungs and airway edges have been carried out. Lastly, by throwing away the airway, lung segmentation has been presented.
Abstract: The objective this study was to characterize and
develop anthropomorphic liver phantoms in tomography hepatic
procedures for quality control and improvement professionals in
nuclear medicine. For the conformation of the anthropomorphic
phantom was used in plaster and acrylic. We constructed three
phantoms representing processes with liver cirrhosis. The phantoms
were filled with 99mTc diluted with water to obtain the scintigraphic
images. Tomography images were analyzed anterior and posterior
phantom representing a body with a greater degree cirrhotic. It was
noted that the phantoms allow the acquisition of images similar to
real liver with cirrhosis. Simulations of hemangiomas may contribute
to continued professional education of nuclear medicine, on the
question of image acquisition, allowing of the study parameters such
of the matrix, energy window and count statistics.
Abstract: Optical Coherence Tomography (OCT) combined
with the Confocal Microscopy, as a noninvasive method, permits the
determinations of materials defects in the ceramic layers depth. For
this study 256 anterior and posterior metal and integral ceramic fixed
partial dentures were used, made with Empress (Ivoclar), Wollceram
and CAD/CAM (Wieland) technology. For each investigate area 350
slices were obtain and a 3D reconstruction was perform from each
stuck. The Optical Coherent Tomography, as a noninvasive method,
can be used as a control technique in integral ceramic technology,
before placing those fixed partial dentures in the oral cavity. The
purpose of this study is to evaluate the capability of En face Optical
Coherence Tomography (OCT) combined with a fluorescent method
in detection and analysis of possible material defects in metalceramic
and integral ceramic fixed partial dentures. As a conclusion,
it is important to have a non invasive method to investigate fixed
partial prostheses before their insertion in the oral cavity in order to
satisfy the high stress requirements and the esthetic function.
Abstract: In this study three commercial semiconductor devices
were characterized in the laboratory for computed tomography
dosimetry: one photodiode and two phototransistors. It was evaluated
four responses to the irradiation: dose linearity, energy dependence,
angular dependence and loss of sensitivity after X ray exposure. The
results showed that the three devices have proportional response with
the air kerma; the energy dependence displayed for each device
suggests that some calibration factors would be applied for each one;
the angular dependence showed a similar pattern among the three
electronic components. In respect to the fourth parameter analyzed,
one phototransistor has the highest sensitivity however it also showed
the greatest loss of sensitivity with the accumulated dose. The
photodiode was the device with the smaller sensitivity to radiation,
on the other hand, the loss of sensitivity after irradiation is negligible.
Since high accuracy is a desired feature for a dosimeter, the
photodiode can be the most suitable of the three devices for
dosimetry in tomography. The phototransistors can also be used for
CT dosimetry, however it would be necessary a correction factor due
to loss of sensitivity with accumulated dose.
Abstract: For investigations of electromagnetic field
distributions in biological structures by Finite Element Method
(FEM), a method for automatic 3D model building of human
anatomical objects is developed. Models are made by meshed
structures and specific electromagnetic material properties for each
tissue type. Mesh is built according to specific FEM criteria for
achieving good solution accuracy. Several FEM models of
anatomical objects are built. Formulation using magnetic vector
potential and scalar electric potential (A-V, A) is used for modeling
of electromagnetic fields in human tissue objects. The developed
models are suitable for investigations of electromagnetic field
distributions in human tissues exposed in external fields during
magnetic stimulation, defibrillation, impedance tomography etc.
Abstract: The stereophotogrammetry modality is gaining more widespread use in the clinical setting. Registration and visualization of this data, in conjunction with conventional 3D volumetric image modalities, provides virtual human data with textured soft tissue and internal anatomical and structural information. In this investigation computed tomography (CT) and stereophotogrammetry data is acquired from 4 anatomical phantoms and registered using the trimmed iterative closest point (TrICP) algorithm. This paper fully addresses the issue of imaging artifacts around the stereophotogrammetry surface edge using the registered CT data as a reference. Several iterative algorithms are implemented to automatically identify and remove stereophotogrammetry surface edge outliers, improving the overall visualization of the combined stereophotogrammetry and CT data. This paper shows that outliers at the surface edge of stereophotogrammetry data can be successfully removed automatically.
Abstract: Discrete Wavelet Transform (DWT) has demonstrated
far superior to previous Discrete Cosine Transform (DCT) and
standard JPEG in natural as well as medical image compression. Due
to its localization properties both in special and transform domain,
the quantization error introduced in DWT does not propagate
globally as in DCT. Moreover, DWT is a global approach that avoids
block artifacts as in the JPEG. However, recent reports on natural
image compression have shown the superior performance of
contourlet transform, a new extension to the wavelet transform in two
dimensions using nonseparable and directional filter banks,
compared to DWT. It is mostly due to the optimality of contourlet in
representing the edges when they are smooth curves. In this work, we
investigate this fact for medical images, especially for CT images,
which has not been reported yet. To do that, we propose a
compression scheme in transform domain and compare the
performance of both DWT and contourlet transform in PSNR for
different compression ratios (CR) using this scheme. The results
obtained using different type of computed tomography images show
that the DWT has still good performance at lower CR but contourlet
transform performs better at higher CR.
Abstract: Electric impedance imaging is a method of
reconstructing spatial distribution of electrical conductivity inside a
subject. In this paper, a new method of electrical impedance imaging
using eddy current is proposed. The eddy current distribution in the
body depends on the conductivity distribution and the magnetic field
pattern. By changing the position of magnetic core, a set of voltage
differences is measured with a pair of electrodes. This set of voltage
differences is used in image reconstruction of conductivity
distribution. The least square error minimization method is used as a
reconstruction algorithm. The back projection algorithm is used to
get two dimensional images. Based on this principle, a measurement
system is developed and some model experiments were performed
with a saline filled phantom. The shape of each model in the
reconstructed image is similar to the corresponding model,
respectively. From the results of these experiments, it is confirmed
that the proposed method is applicable in the realization of electrical
imaging.
Abstract: This paper presents a novel method for prediction of
the mechanical behavior of proximal femur using the general
framework of the quantitative computed tomography (QCT)-based
finite element Analysis (FEA). A systematic imaging and modeling
procedure was developed for reliable correspondence between the
QCT-based FEA and the in-vitro mechanical testing. A speciallydesigned
holding frame was used to define and maintain a unique
geometrical reference system during the analysis and testing. The
QCT images were directly converted into voxel-based 3D finite
element models for linear and nonlinear analyses. The equivalent
plastic strain and the strain energy density measures were used to
identify the critical elements and predict the failure patterns. The
samples were destructively tested using a specially-designed gripping
fixture (with five degrees of freedom) mounted within a universal
mechanical testing machine. Very good agreements were found
between the experimental and the predicted failure patterns and the
associated load levels.
Abstract: The intention of this lessons is to assess the probability
of optical coherence tomography (OCT) for biometric recognition.
The OCT is the foundation on an optical signal acquisition and
processing method and has the micrometer-resolution. In this study,
we used the porcine skin for verifying the abovementioned means. The
porcine tissue was sound acknowledged for structural and
immunohistochemical similarity with human skin, so it could be
suitable for pre-clinical trial as investigational specimen. For this
reason, it was tattooed by the tattoo machine with the tattoo-pigment.
We detected the pattern of the tattooed skin by the OCT according to
needle speed. The result was consistent with the histology images.
This result showed that the OCT was effective to examine the tattooed
skin section noninvasively. It might be available to identify
morphological changes inside the skin.