Abstract: The fixed partial dentures are mainly used in the frontal
part of the dental arch because of their great esthetics. There are
several factors that are associated with the stress state created in
ceramic restorations, including: thickness of ceramic layers,
mechanical properties of the materials, elastic modulus of the
supporting substrate material, direction, magnitude and frequency of
applied load, size and location of occlusal contact areas, residual
stresses induced by processing or pores, restoration-cement
interfacial defects and environmental defects. The purpose of this
study is to evaluate the capability of Polarization Sensitive Optical
Coherence Tomography (PSOCT) in detection and analysis of
possible material defects in metal-ceramic and integral ceramic fixed
partial dentures. As a conclusion, it is important to have a non
invasive method to investigate fixed partial prostheses before their
insertion in the oral cavity in order to satisfy the high stress
requirements and the esthetic function.
Abstract: In this paper, algorithms for the automatic localisation
of two anatomical soft tissue landmarks of the head the medial
canthus (inner corner of the eye) and the tragus (a small, pointed,
cartilaginous flap of the ear), in CT images are describet. These
landmarks are to be used as a basis for an automated image-to-patient
registration system we are developing. The landmarks are localised
on a surface model extracted from CT images, based on surface
curvature and a rule based system that incorporates prior knowledge
of the landmark characteristics. The approach was tested on a dataset
of near isotropic CT images of 95 patients. The position of the
automatically localised landmarks was compared to the position of
the manually localised landmarks. The average difference was 1.5
mm and 0.8 mm for the medial canthus and tragus, with a maximum
difference of 4.5 mm and 2.6 mm respectively.The medial canthus
and tragus can be automatically localised in CT images, with
performance comparable to manual localisation
Abstract: Medical image modalities such as computed
tomography (CT), magnetic resonance imaging (MRI), ultrasound
(US), X-ray are adapted to diagnose disease. These modalities
provide flexible means of reviewing anatomical cross-sections and
physiological state in different parts of the human body. The raw
medical images have a huge file size and need large storage
requirements. So it should be such a way to reduce the size of those
image files to be valid for telemedicine applications. Thus the image
compression is a key factor to reduce the bit rate for transmission or
storage while maintaining an acceptable reproduction quality, but it is
natural to rise the question of how much an image can be compressed
and still preserve sufficient information for a given clinical
application. Many techniques for achieving data compression have
been introduced. In this study, three different MRI modalities which
are Brain, Spine and Knee have been compressed and reconstructed
using wavelet transform. Subjective and objective evaluation has
been done to investigate the clinical information quality of the
compressed images. For the objective evaluation, the results show
that the PSNR which indicates the quality of the reconstructed image
is ranging from (21.95 dB to 30.80 dB, 27.25 dB to 35.75 dB, and
26.93 dB to 34.93 dB) for Brain, Spine, and Knee respectively. For
the subjective evaluation test, the results show that the compression
ratio of 40:1 was acceptable for brain image, whereas for spine and
knee images 50:1 was acceptable.
Abstract: As the Computed Tomography(CT) requires normally
hundreds of projections to reconstruct the image, patients are exposed
to more X-ray energy, which may cause side effects such as cancer.
Even when the variability of the particles in the object is very less,
Computed Tomography requires many projections for good quality
reconstruction. In this paper, less variability of the particles in an
object has been exploited to obtain good quality reconstruction.
Though the reconstructed image and the original image have same
projections, in general, they need not be the same. In addition
to projections, if a priori information about the image is known,
it is possible to obtain good quality reconstructed image. In this
paper, it has been shown by experimental results why conventional
algorithms fail to reconstruct from a few projections, and an efficient
polynomial time algorithm has been given to reconstruct a bi-level
image from its projections along row and column, and a known sub
image of unknown image with smoothness constraints by reducing the
reconstruction problem to integral max flow problem. This paper also
discusses the necessary and sufficient conditions for uniqueness and
extension of 2D-bi-level image reconstruction to 3D-bi-level image
reconstruction.
Abstract: Computed tomography and laminography are heavily investigated in a compressive sensing based image reconstruction framework to reduce the dose to the patients as well as to the radiosensitive devices such as multilayer microelectronic circuit boards. Nowadays researchers are actively working on optimizing the compressive sensing based iterative image reconstruction algorithm to obtain better quality images. However, the effects of the sampled data’s properties on reconstructed the image’s quality, particularly in an insufficient sampled data conditions have not been explored in computed laminography. In this paper, we investigated the effects of two data properties i.e. sampling density and data incoherence on the reconstructed image obtained by conventional computed laminography and a recently proposed method called spherical sinusoidal scanning scheme. We have found that in a compressive sensing based image reconstruction framework, the image quality mainly depends upon the data incoherence when the data is uniformly sampled.
Abstract: Liver segmentation is the first significant process for
liver diagnosis of the Computed Tomography. It segments the liver
structure from other abdominal organs. Sophisticated filtering techniques
are indispensable for a proper segmentation. In this paper, we
employ a 3D anisotropic diffusion as a preprocessing step. While
removing image noise, this technique preserve the significant parts
of the image, typically edges, lines or other details that are important
for the interpretation of the image. The segmentation task is done
by using thresholding with automatic threshold values selection and
finally the false liver region is eliminated using 3D connected component.
The result shows that by employing the 3D anisotropic filtering,
better liver segmentation results could be achieved eventhough simple
segmentation technique is used.
Abstract: Accurate timing alignment and stability is important
to maximize the true counts and minimize the random counts in
positron emission tomography So signals output from detectors must
be centering with the two isotopes to pre-operation and fed signals
into four units of pulse-processing units, each unit can accept up to
eight inputs. The dual source computed tomography consist two units
on the left for 15 detector signals of Cs-137 isotope and two units on
the right are for 15 detectors signals of Co-60 isotope. The gamma
spectrum consisting of either single or multiple photo peaks. This
allows for the use of energy discrimination electronic hardware
associated with the data acquisition system to acquire photon counts
data with a specific energy, even if poor energy resolution detectors
are used. This also helps to avoid counting of the Compton scatter
counts especially if a single discrete gamma photo peak is emitted by
the source as in the case of Cs-137. In this study the polyenergetic
version of the alternating minimization algorithm is applied to the
dual energy gamma computed tomography problem.
Abstract: Ultrasound is useful in demonstrating bone mineral
density of regenerating osseous tissue as well as structural alterations.
A proposed ultrasound method, which included ultrasonography and
acoustic parameters measurement, was employed to evaluate its
efficacy in monitoring the bone callus changes in a rabbit tibial
distraction osteogenesis (DO) model.
The findings demonstrated that ultrasonographic images depicted
characteristic changes of the bone callus, typical of histology findings,
during the distraction phase. Follow-up acoustic parameters
measurement of the bone callus, including speed of sound, reflection
and attenuation, showed significant linear changes over time during
the distraction phase. The acoustic parameters obtained during the
distraction phase also showed moderate to strong correlation with
consolidated bone callus density and micro-architecture measured by
micro-computed tomography at the end of the consolidation phase.
The results support the preferred use of ultrasound imaging in the
early monitoring of bone callus changes during DO treatment.
Abstract: We study the problem of reconstructing a three dimensional binary matrices whose interiors are only accessible through few projections. Such question is prominently motivated by the demand in material science for developing tool for reconstruction of crystalline structures from their images obtained by high-resolution transmission electron microscopy. Various approaches have been suggested to reconstruct 3D-object (crystalline structure) by reconstructing slice of the 3D-object. To handle the ill-posedness of the problem, a priori information such as convexity, connectivity and periodicity are used to limit the number of possible solutions. Formally, 3Dobject (crystalline structure) having a priory information is modeled by a class of 3D-binary matrices satisfying a priori information. We consider 3D-binary matrices with periodicity constraints, and we propose a polynomial time algorithm to reconstruct 3D-binary matrices with periodicity constraints from two orthogonal projections.
Abstract: The Brazilian legislation has only established
diagnostic reference levels (DRLs) in terms of Multiple Scan
Average Dose (MSAD) as a quality control parameter for computed
tomography (CT) scanners. Compliance with DRLs can be verified
by measuring the Computed Tomography Kerma Index (Ca,100) with
a pencil ionization chamber or by obtaining the kerma distribution in
CT scans with radiochromic films or rod shape lithium fluoride
termoluminescent dosimeters (TLD-100). TL dosimeters were used
to record kerma profiles and to determine MSAD values of a Bright
Speed model GE CT scanner. Measurements were done with
radiochromic films and TL dosimeters distributed in cylinders
positioned in the center and in four peripheral bores of a standard
polymethylmethacrylate (PMMA) body CT dosimetry phantom.
Irradiations were done using a protocol for adult chest. The
maximum values were found at the midpoint of the longitudinal axis.
The MSAD values obtained with three dosimetric techniques were
compared.
Abstract: The purpose of this study is to introduce a new
interface program to calculate a dose distribution with Monte Carlo method in complex heterogeneous systems such as organs or tissues
in proton therapy. This interface program was developed under
MATLAB software and includes a friendly graphical user interface
with several tools such as image properties adjustment or results display. Quadtree decomposition technique was used as an image
segmentation algorithm to create optimum geometries from Computed Tomography (CT) images for dose calculations of proton
beam. The result of the mentioned technique is a number of nonoverlapped
squares with different sizes in every image. By this way
the resolution of image segmentation is high enough in and near
heterogeneous areas to preserve the precision of dose calculations
and is low enough in homogeneous areas to reduce the number of
cells directly. Furthermore a cell reduction algorithm can be used to combine neighboring cells with the same material. The validation of this method has been done in two ways; first, in comparison with experimental data obtained with 80 MeV proton beam in Cyclotron
and Radioisotope Center (CYRIC) in Tohoku University and second, in comparison with data based on polybinary tissue calibration method, performed in CYRIC. These results are presented in this paper. This program can read the output file of Monte Carlo code while region of interest is selected manually, and give a plot of dose distribution of proton beam superimposed onto the CT images.
Abstract: Cross sections of As radionuclides in the interaction of natGe with 14-30 MeV protons have been deduced by off-line y-ray spectroscopy to find optimal reaction channels leading to radiotracers for positron emission tomography. The experimental results were compared with the previous results and those estimated by the compound nucleus reaction model.
Abstract: In this paper we describe a computer-aided diagnosis (CAD) system for automated detection of pulmonary nodules in computed-tomography (CT) images. After extracting the pulmonary parenchyma using a combination of image processing techniques, a region growing method is applied to detect nodules based on 3D geometric features. We applied the CAD system to CT scans collected in a screening program for lung cancer detection. Each scan consists of a sequence of about 300 slices stored in DICOM (Digital Imaging and Communications in Medicine) format. All malignant nodules were detected and a low false-positive detection rate was achieved.
Abstract: In this paper, a novel and fast algorithm for segmental
and subsegmental lung vessel segmentation is introduced using
Computed Tomography Angiography images. This process is quite
important especially at the detection of pulmonary embolism, lung
nodule, and interstitial lung disease. The applied method has been
realized at five steps. At the first step, lung segmentation is achieved.
At the second one, images are threshold and differences between the
images are detected. At the third one, left and right lungs are gathered
with the differences which are attained in the second step and Exact
Lung Image (ELI) is achieved. At the fourth one, image, which is
threshold for vessel, is gathered with the ELI. Lastly, identifying and
segmentation of segmental and subsegmental lung vessel have been
carried out thanks to image which is obtained in the fourth step. The
performance of the applied method is found quite well for
radiologists and it gives enough results to the surgeries medically.
Abstract: This paper deals with the extraction of information from the experts to automatically identify and recognize Ganoderma infection in oil palm stem using tomography images. Expert-s knowledge are used as rules in a Fuzzy Inference Systems to classify each individual patterns observed in he tomography image. The classification is done by defining membership functions which assigned a set of three possible hypotheses : Ganoderma infection (G), non Ganoderma infection (N) or intact stem tissue (I) to every abnormalities pattern found in the tomography image. A complete comparison between Mamdani and Sugeno style,triangular, trapezoids and mixed triangular-trapezoids membership functions and different methods of aggregation and defuzzification is also presented and analyzed to select suitable Fuzzy Inference System methods to perform the above mentioned task. The results showed that seven out of 30 initial possible combination of available Fuzzy Inference methods in MATLAB Fuzzy Toolbox were observed giving result close to the experts estimation.
Abstract: The aim of the present study is to analyze the generation of osteoporotic vertebral bone induced by lack of calcium during growth period and analyze its effects for disc degeneration, based on biomechanical and histomorphometrical study. Mechanical and histomorphological characteristics of lumbar vertebral bones and discs of rats with calcium free diet (CFD) were detected and tracked by using high resolution in-vivo micro-computed tomography (in-vivo micro-CT), finite element (FE) and histological analysis. Twenty female Sprague-Dawley rats (6 weeks old, approximate weight 170g) were randomly divided into two groups (CFD group: 10, NOR group: 10). The CFD group was maintained on a refmed calcium-controlled semisynthetic diet without added calcium, to induce osteoporosis. All lumbar (L 1-L6) were scanned by using in vivo micro-CT with 35i.un resolution at 0, 4, 8 weeks to track the effects of CFD on the generation of osteoporosis. The fmdings of the present study indicated that calcium insufficiency was the main factor in the generation of osteoporosis and it induced lumbar vertebral disc degeneration. This study is a valuable experiment to firstly evaluate osteoporotic vertebral bone and disc degeneration induced by lack of calcium during growth period from a biomechanical and histomorphometrical point of view.
Abstract: Advances in clinical medical imaging have brought about the routine production of vast numbers of medical images that need to be analyzed. As a result an enormous amount of computer vision research effort has been targeted at achieving automated medical image analysis. Computed Tomography (CT) is highly accurate for diagnosing liver tumors. This study aimed to evaluate the potential role of the wavelet and the neural network in the differential diagnosis of liver tumors in CT images. The tumors considered in this study are hepatocellular carcinoma, cholangio carcinoma, hemangeoma and hepatoadenoma. Each suspicious tumor region was automatically extracted from the CT abdominal images and the textural information obtained was used to train the Probabilistic Neural Network (PNN) to classify the tumors. Results obtained were evaluated with the help of radiologists. The system differentiates the tumor with relatively high accuracy and is therefore clinically useful.
Abstract: Semiconductor detector arrays are widely used in
high-temperature plasma diagnostics. They have a fast response,
which allows observation of many processes and instabilities in
tokamaks. In this paper, there are reviewed several diagnostics based
on semiconductor arrays as cameras, AXUV photodiodes (referred
often as fast “bolometers") and detectors of both soft X-rays and
visible light installed on the COMPASS tokamak recently. Fresh
results from both spring and summer campaigns in 2012 are
introduced. Examples of the utilization of the detectors are shown on
the plasma shape determination, fast calculation of the radiation
center, two-dimensional plasma radiation tomography in different
spectral ranges, observation of impurity inflow, and also on
investigation of MHD activity in the COMPASS tokamak discharges.
Abstract: Most CT reconstruction system x-ray computed
tomography (CT) is a well established visualization technique in
medicine and nondestructive testing. However, since CT scanning
requires sampling of radiographic projections from different viewing
angles, common CT systems with mechanically moving parts are too
slow for dynamic imaging, for instance of multiphase flows or live
animals. A large number of X-ray projections are needed to
reconstruct CT images, so the collection and calculation of the
projection data consume too much time and harmful for patient. For
the purpose of solving the problem, in this study, we proposed a
method for tomographic reconstruction of a sample from a limited
number of x-ray projections by using linear interpolation method. In
simulation, we presented reconstruction from an experimental x-ray
CT scan of a Aluminum phantom that follows to two steps: X-ray
projections will be interpolated using linear interpolation method and
using it for CT reconstruction based upon Ordered Subsets
Expectation Maximization (OSEM) method.
Abstract: A 3D industrial computed tomography (CT)
manufactured based on a first generation CT systems, single-source
– single-detector, was evaluated. Operation accuracy assessment of
the manufactured system was achieved using simulation in
comparison with experimental tests. 137Cs and 60Co were used as a gamma source. Simulations were achieved using MCNP4C code.
Experimental tests of 137Cs were in good agreement with the simulations