Abstract: In this paper, we discuss the propagation of sound in the narrow pathways of an occluded-ear simulator typically used for the measurement of insert-type earphones. The simulator has a standardized frequency response conforming to the international standard (IEC60318-4). In narrow pathways, the speed and phase of sound waves are modified by viscous air damping. In our previous paper, we proposed a new finite element method (FEM) to consider the effects of air viscosity in this type of audio equipment. In this study, we will compare the results from the ear simulator FEM model, and those from a three dimensional human ear canal FEM model made from computed tomography images, with the measured frequency response data from the ear canals of 18 people.
Abstract: This article presents the comparison of selected evaluation methods regarding microstructure modification of hardened cement concrete intended for airfield pavements. Basic test results were presented for two pavement quality concrete lots. Analysis included standard concrete used for airfield pavements and modern material solutions based on concrete composite modification. In case of basic grain size distribution of concrete cement CEM I 42,5HSR NA, fine aggregate and coarse aggregate fractions in the form of granite chippings, water and admixtures were considered. In case of grain size distribution of modified concrete, the use of modern modifier as substitute of fine aggregate was suggested. Modification influence on internal concrete structure parameters using scanning electron microscope was defined. Obtained images were compared to the results obtained using computed tomography. Opportunity to use this type of equipment for internal concrete structure diagnostics and an attempt of its parameters evaluation was presented. Obtained test results enabled to reach a conclusion that both methods can be applied for pavement quality concrete diagnostics, with particular purpose of airfield pavements.
Abstract: Quantitative measurement of myocardium perfusion is possible with single photon emission computed tomography (SPECT) using a semiconductor detector. However, accumulation of 99mTc-tetrofosmin in the liver may make it difficult to assess that accurately in the inferior myocardium. Our idea is to reduce the high accumulation in the liver by using dynamic SPECT imaging and a technique called time subtraction. We evaluated the performance of a new SPECT system with a cadmium-zinc-telluride solid-state semi- conductor detector (Discovery NM 530c; GE Healthcare). Our system acquired list-mode raw data over 10 minutes for a typical patient. From the data, ten SPECT images were reconstructed, one for every minute of acquired data. Reconstruction with the semiconductor detector was based on an implementation of a 3-D iterative Bayesian reconstruction algorithm. We studied 20 patients with coronary artery disease (mean age 75.4 ± 12.1 years; range 42-86; 16 males and 4 females). In each subject, 259 MBq of 99mTc-tetrofosmin was injected intravenously. We performed both a phantom and a clinical study using dynamic SPECT. An approximation to a liver-only image is obtained by reconstructing an image from the early projections during which time the liver accumulation dominates (0.5~2.5 minutes SPECT image-5~10 minutes SPECT image). The extracted liver-only image is then subtracted from a later SPECT image that shows both the liver and the myocardial uptake (5~10 minutes SPECT image-liver-only image). The time subtraction of liver was possible in both a phantom and the clinical study. The visualization of the inferior myocardium was improved. In past reports, higher accumulation in the myocardium due to the overlap of the liver is un-diagnosable. Using our time subtraction method, the image quality of the 99mTc-tetorofosmin myocardial SPECT image is considerably improved.
Abstract: By means of the ultrafast X-ray tomography facility, data were obtained at different superficial gas velocities UG in a bubble column (0.1 m in ID) operated with an air-deionized water system at ambient conditions. Raw reconstructed images were treated by both the information entropy (IE) and the reconstruction entropy (RE) algorithms in order to identify the main transition velocities in a bubble column. The IE values exhibited two well-pronounced minima at UG=0.025 m/s and UG=0.085 m/s identifying the boundaries of the homogeneous, transition and heterogeneous regimes. The RE extracted from the central region of the column’s cross-section exhibited only one characteristic peak at UG=0.03 m/s, which was attributed to the transition from the homogeneous to the heterogeneous flow regime. This result implies that the transition regime is non-existent in the core of the column.
Abstract: Photoacoustic imaging is the imaging technology that combines the optical imaging and ultrasound. This provides the high contrast and resolution due to optical imaging and ultrasound imaging, respectively. We developed the real-time photoacoustic tomography (PAT) system using linear-ultrasound transducer and digital acquisition (DAQ) board. There are two types of algorithm for reconstructing the photoacoustic signal. One is back-projection algorithm, the other is FFT algorithm. Especially, we used the non-uniform FFT algorithm. To evaluate the performance of our system and algorithms, we monitored two wires that stands at interval of 2.89 mm and 0.87 mm. Then, we compared the images reconstructed by algorithms. Finally, we monitored the two hairs crossed and compared between these algorithms.
Abstract: An in vitro study was carried out to evaluate the feasibility of small field of view (FOV) cone beam computed tomography (CBCT) in determining endodontic working length. The objectives were to determine the accuracy of CBCT in measuring the estimated preoperative working lengths (EPWL), endodontic working lengths (EWL) and file lengths. Access cavities were prepared in 27 molars. For each root canal, the baseline electronic working length was determined using an EAL (Raypex 5). The teeth were then divided into overextended, non-modified and underextended groups and the lengths were adjusted accordingly. Imaging and measurements were made using the respective software of the RVG (Kodak RVG 6100) and CBCT units (Kodak 9000 3D). Root apices were then shaved and the apical constrictions viewed under magnification to measure the control working lengths. The paired t-test showed a statistically significant difference between CBCT EPWL and control length but the difference was too small to be clinically significant. From the Bland Altman analysis, the CBCT method had the widest range of 95% limits of agreement, reflecting its greater potential of error. In measuring file lengths, RVG had a bigger window of 95% limits of agreement compared to CBCT. Conclusions: (1) The clinically insignificant underestimation of the preoperative working length using small FOV CBCT showed that it is acceptable for use in the estimation of preoperative working length. (2) Small FOV CBCT may be used in working length determination but it is not as accurate as the currently practiced method of using the EAL. (3) It is also more accurate than RVG in measuring file lengths.
Abstract: Diffuse Optical Tomography (DOT) is a non-invasive imaging modality used in clinical diagnosis for earlier detection of carcinoma cells in brain tissue. It is a form of optical tomography which produces gives the reconstructed image of a human soft tissue with by using near-infra-red light. It comprises of two steps called forward model and inverse model. The forward model provides the light propagation in a biological medium. The inverse model uses the scattered light to collect the optical parameters of human tissue. DOT suffers from severe ill-posedness due to its incomplete measurement data. So the accurate analysis of this modality is very complicated. To overcome this problem, optical properties of the soft tissue such as absorption coefficient, scattering coefficient, optical flux are processed by the standard regularization technique called Levenberg - Marquardt regularization. The reconstruction algorithms such as Split Bregman and Gradient projection for sparse reconstruction (GPSR) methods are used to reconstruct the image of a human soft tissue for tumour detection. Among these algorithms, Split Bregman method provides better performance than GPSR algorithm. The parameters such as signal to noise ratio (SNR), contrast to noise ratio (CNR), relative error (RE) and CPU time for reconstructing images are analyzed to get a better performance.
Abstract: The photoacoustic images are obtained from a custom developed linear array photoacoustic tomography system. The biological specimens are imitated by conducting phantom tests in order to retrieve a fully functional photoacoustic image. The acquired image undergoes the active region based contour filtering to remove the noise and accurately segment the object area for further processing. The universal back projection method is used as the image reconstruction algorithm. The active contour filtering is analyzed by evaluating the signal to noise ratio and comparing it with the other filtering methods.
Abstract: Neurological disorders are the most debilitating of manifestations seen in patients infected with HIV. The clinical profile of neurological manifestations in HIV patients has undergone a shift in recent years with opportunistic infections being controlled with combination anti-retroviral therapy and the advent of drugs which have higher central nervous system penetrability. The aim of this paper is to study the clinical, investigation profile and various neurological disorders in HIV patients on anti‐retroviral therapy. Fifty HIV patients with neurological manifestations were studied. A complete neurological examination including neurocognitive functioning using Montreal Cognitive Assessment and HIV Dementia scale were assessed. Apart from relevant investigations, CD4 count, cerebrovascular fluid analysis, computed tomography (CT) and magnetic resonance imaging (MRI) of brain were done whenever required. Neurocognitive disorders formed the largest group with 42% suffering from HIV associated Neurocognitive Disorders. Among them, asymptomatic neurocognitive impairment was seen in 28%; mild neurocognitive disorder in 12%, and 2% had HIV‐associated dementia. Opportunistic infections of the nervous system accounted for 32%, with meningitis being the most common. Four patients had space occupying lesions of central nervous system; four tuberculomas, and one toxoplasmosis. With the advent of highly active retroviral therapy, HIV patients have longer life spans with suppression of viral load leading to decrease in opportunistic infections of the nervous system. Neurocognitive disorders are now the most common neurological dysfunction seen and thus neurocognitive assessment must be done in all patients with HIV.
Abstract: Medical digital images usually have low resolution because of nature of their acquisition. Therefore, this paper focuses on zooming these images to obtain better level of information, required for the purpose of medical diagnosis. For this purpose, a strategy for selecting pixels in zooming operation is proposed. It is based on the principle of analog clock and utilizes a combination of point and neighborhood image processing. In this approach, the hour hand of clock covers the portion of image to be processed. For alignment, the center of clock points at middle pixel of the selected portion of image. The minute hand is longer in length, and is used to gain information about pixels of the surrounding area. This area is called neighborhood pixels region. This information is used to zoom the selected portion of the image. The proposed algorithm is implemented and its performance is evaluated for many medical images obtained from various sources such as X-ray, Computerized Tomography (CT) scan and Magnetic Resonance Imaging (MRI). However, for illustration and simplicity, the results obtained from a CT scanned image of head is presented. The performance of algorithm is evaluated in comparison to various traditional algorithms in terms of Peak signal-to-noise ratio (PSNR), maximum error, SSIM index, mutual information and processing time. From the results, the proposed algorithm is found to give better performance than traditional algorithms.
Abstract: A conventional optical coherence tomography (OCT) system has limited imaging depth, which is 1-2 mm, and suffers unwanted noise such as speckle noise. The motorized-stage-based OCT system, using a common-path Fourier-domain optical coherence tomography (CP-FD-OCT) configuration, provides enhanced imaging depth and less noise so that we can overcome these limitations. Using this OCT systems, OCT images were obtained from an onion, and their subsurface structure was observed. As a result, the images obtained using the developed motorized-stage-based system showed enhanced imaging depth than the conventional system, since it is real-time accurate depth tracking. Consequently, the developed CP-FD-OCT systems and algorithms have good potential for the further development of endoscopic OCT for microsurgery.
Abstract: Electrical impedance tomography is a non-invasive medical imaging technique suitable for medical applications. This paper describes an electrical impedance tomography device with the ability to navigate a robotic arm to manipulate a target object. The design of the device includes various hardware and software sections to perform medical imaging and control the robotic arm. In its hardware section an image is formed by 16 electrodes which are located around a container. This image is used to navigate a 3DOF robotic arm to reach the exact location of the target object. The data set to form the impedance imaging is obtained by having repeated current injections and voltage measurements between all electrode pairs. After performing the necessary calculations to obtain the impedance, information is transmitted to the computer. This data is fed and then executed in MATLAB which is interfaced with EIDORS (Electrical Impedance Tomography Reconstruction Software) to reconstruct the image based on the acquired data. In the next step, the coordinates of the center of the target object are calculated by image processing toolbox of MATLAB (IPT). Finally, these coordinates are used to calculate the angles of each joint of the robotic arm. The robotic arm moves to the desired tissue with the user command.
Abstract: In this paper, an approach for the liver tumor detection
in computed tomography (CT) images is represented. The detection
process is based on classifying the features of target liver cell to
either tumor or non-tumor. Fractional differential (FD) is applied for
enhancement of Liver CT images, with the aim of enhancing texture
and edge features. Later on, a fusion method is applied to merge
between the various enhanced images and produce a variety of
feature improvement, which will increase the accuracy of
classification. Each image is divided into NxN non-overlapping
blocks, to extract the desired features. Support vector machines
(SVM) classifier is trained later on a supplied dataset different from
the tested one. Finally, the block cells are identified whether they are
classified as tumor or not. Our approach is validated on a group of
patients’ CT liver tumor datasets. The experiment results
demonstrated the efficiency of detection in the proposed technique.
Abstract: Liver segmentation from medical images poses more
challenges than analogous segmentations of other organs. This
contribution introduces a liver segmentation method from a series of
computer tomography images. Overall, we present a novel method for
segmenting liver by coupling density matching with shape priors.
Density matching signifies a tracking method which operates via
maximizing the Bhattacharyya similarity measure between the
photometric distribution from an estimated image region and a model
photometric distribution. Density matching controls the direction of
the evolution process and slows down the evolving contour in regions
with weak edges. The shape prior improves the robustness of density
matching and discourages the evolving contour from exceeding liver’s
boundaries at regions with weak boundaries. The model is
implemented using a modified distance regularized level set (DRLS)
model. The experimental results show that the method achieves a
satisfactory result. By comparing with the original DRLS model, it is
evident that the proposed model herein is more effective in addressing
the over segmentation problem. Finally, we gauge our performance of
our model against matrices comprising of accuracy, sensitivity, and
specificity.
Abstract: Background: To compare the thinning patterns of the
ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal
nerve fiber layer (pRNFL) as measured using Cirrus high-definition
optical coherence tomography (HD-OCT) in patients with visual field
(VF) defects that respect the vertical meridian. Methods: Twenty eyes of eleven patients with VF defects that
respect the vertical meridian were enrolled retrospectively. The
thicknesses of the macular GCIPL and pRNFL were measured using
Cirrus HD-OCT. The 5% and 1% thinning area index (TAI) was
calculated as the proportion of abnormally thin sectors at the 5% and
1% probability level within the area corresponding to the affected VF.
The 5% and 1% TAI were compared between the GCIPL and pRNFL
measurements. Results: The color-coded GCIPL deviation map showed a
characteristic vertical thinning pattern of the GCIPL, which is also
seen in the VF of patients with brain lesions. The 5% and 1% TAI
were significantly higher in the GCIPL measurements than in the
pRNFL measurements (all P < 0.01). Conclusions: Macular GCIPL analysis clearly visualized a
characteristic topographic pattern of retinal ganglion cell (RGC) loss
in patients with VF defects that respect the vertical meridian, unlike
pRNFL measurements. Macular GCIPL measurements provide more
valuable information than pRNFL measurements for detecting the
loss of RGCs in patients with retrograde degeneration of the optic
nerve fibers.
Abstract: One of the most important challenging factors in
medical images is nominated as noise. Image denoising refers to the
improvement of a digital medical image that has been infected by
Additive White Gaussian Noise (AWGN). The digital medical image
or video can be affected by different types of noises. They are
impulse noise, Poisson noise and AWGN. Computed tomography
(CT) images are subjects to low quality due to the noise. Quality of
CT images is dependent on absorbed dose to patients directly in such
a way that increase in absorbed radiation, consequently absorbed
dose to patients (ADP), enhances the CT images quality. In this
manner, noise reduction techniques on purpose of images quality
enhancement exposing no excess radiation to patients is one the
challenging problems for CT images processing. In this work, noise
reduction in CT images was performed using two different
directional 2 dimensional (2D) transformations; i.e., Curvelet and
Contourlet and Discrete Wavelet Transform (DWT) thresholding
methods of BayesShrink and AdaptShrink, compared to each other
and we proposed a new threshold in wavelet domain for not only
noise reduction but also edge retaining, consequently the proposed
method retains the modified coefficients significantly that result good
visual quality. Data evaluations were accomplished by using two
criterions; namely, peak signal to noise ratio (PSNR) and Structure
similarity (Ssim).
Abstract: This work presents an improved single fiber pull-out
test for fiber/matrix interface characterization. This test has been
used to study the Inter-Facial Shear Strength ‘IFSS’ of hemp fibers
reinforced polypropylene (PP). For this aim, the fiber diameter
has been carefully measured using a tomography inspired method.
The fiber section contour can then be approximated by a circle
or a polygon. The results show that the IFSS is overestimated if
the circular approximation is used. The Influence of the molding
temperature on the IFSS has also been studied. We find that a molding
temperature of 183◦C leads to better interfacial properties. Above or
below this temperature the interface strength is reduced.
Abstract: Studying stress and strain trends in the femur and
recognizing femur failure mechanism is very important for
preventing hip fracture in the elderly. The aim of this study was to
identify high stress and strain regions in the femur during normal
walking and falling to find the mechanical behavior and failure
mechanism of the femur. We developed a finite element model of the
femur from the subject’s quantitative computed tomography (QCT)
image and used it to identify potentially high stress and strain regions
during the single-leg stance and the sideways fall. It was found that
fracture may initiate from the superior region of femoral neck and
propagate to the inferior region during a high impact force such as
sideways fall. The results of this study showed that the femur bone is
more sensitive to strain than stress which indicates the effect of
strain, in addition to effect of stress, should be considered for failure
analysis.
Abstract: Neural activity in the human brain starts from the
early stages of prenatal development. This activity or signals
generated by the brain are electrical in nature and represent not only
the brain function but also the status of the whole body. At the
present moment, three methods can record functional and
physiological changes within the brain with high temporal resolution
of neuronal interactions at the network level: the
electroencephalogram (EEG), the magnet oencephalogram (MEG),
and functional magnetic resonance imaging (fMRI); each of these has
advantages and shortcomings. EEG recording with a large number of
electrodes is now feasible in clinical practice. Multichannel EEG
recorded from the scalp surface provides very valuable but indirect
information about the source distribution. However, deep electrode
measurements yield more reliable information about the source
locations intracranial recordings and scalp EEG are used with the
source imaging techniques to determine the locations and strengths of
the epileptic activity. As a source localization method, Low
Resolution Electro-Magnetic Tomography (LORETA) is solved for
the realistic geometry based on both forward methods, the Boundary
Element Method (BEM) and the Finite Difference Method (FDM). In
this paper, we review the findings EEG- LORETA about epilepsy.
Abstract: The aim of this study is to evaluate the effects of the
laser and partial vibration stimulation on the mice tibia with
morphological characteristics. Twenty female C57BL/6 mice (12
weeks old) were used for the experiment. The study was carried out on
four groups of animals each consisting of five mice. Four groups of
mice were ovariectomized. Animals were scanned at 0 and 2 weeks
after ovariectomy by using micro computed tomography to estimate
morphological characteristics of tibial trabecular bone. Morphological
analysis showed that structural parameters of multi-stimuli group
appear significantly better phase in BV/TV, BS/BV, Tb.Th, Tb.N,
Tb.Sp, and Tb.pf than single stimulation groups. However, single
stimulation groups didn’t show significant effect on tibia with Sham
group. This study suggests that multi-stimuli may restrain the change
as the degenerate phase on osteoporosis in the mice tibia.