Abstract: Nitrogen-doped graphene quantum dots (N-GQDs)
were fabricated by microwave-assisted hydrothermal technique. The
optical properties of the N-GQDs were studied. The luminescence of
the N-GQDs can be tuned by varying the excitation wavelength.
Furthermore, two-photon luminescence of the N-GQDs excited by
near-infrared laser can be obtained. It is shown that N-doping play a
key role on two-photon luminescence. The N-GQDs are expected to
find application in biological applications including bioimaging and
sensing.
Abstract: This study compares the quality of different brands of Portland Cement (PC) available in Libyan market. The amounts of chemical constituents like SiO2, Al2O3, Fe2O3, CaO, MgO, SO3 and Lime Saturation Factor (LSF) were determined in accordance with Libyan (L.S.S) and Amrican (A.S.S) Standard Specifications. All the cement studies were found to be good for concrete work especially where no special property is required. The chemical and mineralogical analyses for studied clinker samples show that the dominant phases composition are C3S and C2S while the C3A and C4AF are less abundant.
Abstract: Optical Coherence Tomography (OCT) combined
with the Confocal Microscopy, as a noninvasive method, permits the
determinations of materials defects in the ceramic layers depth. For
this study 256 anterior and posterior metal and integral ceramic fixed
partial dentures were used, made with Empress (Ivoclar), Wollceram
and CAD/CAM (Wieland) technology. For each investigate area 350
slices were obtain and a 3D reconstruction was perform from each
stuck. The Optical Coherent Tomography, as a noninvasive method,
can be used as a control technique in integral ceramic technology,
before placing those fixed partial dentures in the oral cavity. The
purpose of this study is to evaluate the capability of En face Optical
Coherence Tomography (OCT) combined with a fluorescent method
in detection and analysis of possible material defects in metalceramic
and integral ceramic fixed partial dentures. As a conclusion,
it is important to have a non invasive method to investigate fixed
partial prostheses before their insertion in the oral cavity in order to
satisfy the high stress requirements and the esthetic function.
Abstract: Identifying the nature of protein-nanoparticle
interactions and favored binding sites is an important issue in
functional characterization of biomolecules and their physiological
responses. Herein, interaction of silver nanoparticles with lysozyme
as a model protein has been monitored via fluorescence spectroscopy.
Formation of complex between the biomolecule and silver
nanoparticles (AgNPs) induced a steady state reduction in the
fluorescence intensity of protein at different concentrations of
nanoparticles. Tryptophan fluorescence quenching spectra suggested
that silver nanoparticles act as a foreign quencher, approaching the
protein via this residue. Analysis of the Stern-Volmer plot showed
quenching constant of 3.73 μM−1. Moreover, a single binding site in
lysozyme is suggested to play role during interaction with AgNPs,
having low affinity of binding compared to gold nanoparticles.
Unfolding studies of lysozyme showed that complex of lysozyme-
AgNPs has not undergone structural perturbations compared to the
bare protein. Results of this effort will pave the way for utilization of
sensitive spectroscopic techniques for rational design of
nanobiomaterials in biomedical applications.
Abstract: Breast carcinoma is the most common form of cancer
in women. Multicolour fluorescent in-situ hybridisation (m-FISH) is
a common method for staging breast carcinoma. The interpretation
of m-FISH images is complicated due to two effects: (i) Spectral
overlap in the emission spectra of fluorochrome marked DNA probes
and (ii) tissue autofluorescence. In this paper hyper-spectral images of
m-FISH samples are used and spectral unmixing is applied to produce
false colour images with higher contrast and better information
content than standard RGB images. The spectral unmixing is realised
by combinations of: Orthogonal Projection Analysis (OPA), Alterating
Least Squares (ALS), Simple-to-use Interactive Self-Modeling
Mixture Analysis (SIMPLISMA) and VARIMAX. These are applied
on the data to reduce tissue autofluorescence and resolve the spectral
overlap in the emission spectra. The results show that spectral unmixing
methods reduce the intensity caused by tissue autofluorescence by
up to 78% and enhance image contrast by algorithmically reducing
the overlap of the emission spectra.
Abstract: The purpose of this study is to present a non invasive
method for the marginal adaptation evaluation in class V composite
restorations. Standardized class V cavities, prepared in human
extracted teeth, were filled with Premise (Kerr) composite. The
specimens were thermo cycled. The interfaces were examined by
Optical Coherence Tomography method (OCT) combined with the
confocal microscopy and fluorescence. The optical configuration
uses two single mode directional couplers with a superluminiscent
diode as the source at 1300 nm. The scanning procedure is similar to
that used in any confocal microscope, where the fast scanning is enface
(line rate) and the depth scanning is much slower (at the frame
rate). Gaps at the interfaces as well as inside the composite resin
materials were identified. OCT has numerous advantages which
justify its use in vivo as well as in vitro in comparison with
conventional techniques.