Abstract: Laser beam forming is a novel technique developed for the joining of metallic components. In this study, an overview of the laser beam forming process, areas of application, the basic mechanisms of the laser beam forming process, some recent research
studies and the need to focus more research effort on improving the
laser-material interaction of laser beam forming of titanium and its
alloys are presented.
Abstract: Shape memory alloy (SMA) actuators have found a
wide range of applications due to their unique properties such as high
force, small size, lightweight and silent operation. This paper presents
the development of compact (SMA) actuator and cooling system in
one unit. This actuator is developed for multi-fingered hand. It
consists of nickel-titanium (Nitinol) SMA wires in compact forming.
The new arrangement insulates SMA wires from the human body by
housing it in a heat sink and uses a thermoelectric device for rejecting
heat to improve the actuator performance. The study uses
optimization methods for selecting the SMA wires geometrical
parameters and the material of a heat sink. The experimental work
implements the actuator prototype and measures its response.
Abstract: Electrochemical-oxidation of Reactive Black-5 (RB- 5) was conducted for degradation using DSA type Ti/RuO2-SnO2- Sb2O5 electrode. In the study, for electro-oxidation, electrode was indigenously fabricated in laboratory using titanium as substrate. This substrate was coated using different metal oxides RuO2, Sb2O5 and SnO2 by thermal decomposition method. Laboratory scale batch reactor was used for degradation and decolorization studies at pH 2, 7 and 11. Current density (50mA/cm2) and distance between electrodes (8mm) were kept constant for all experiments. Under identical conditions, removal of color, COD and TOC at initial pH 2 was 99.40%, 55% and 37% respectively for initial concentration of 100 mg/L RB-5. Surface morphology and composition of the fabricated electrode coatings were characterized using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) respectively. Coating microstructure was analyzed by X-ray diffraction (XRD). Results of this study further revealed that almost 90% of oxidation occurred within 5-10 minutes.
Abstract: The primary objective of this research is to improve the flexural capacity of FRP strengthened RC Beam structures with Aluminum and Titanium laminates. FRP rupture of flexural strengthened RC beams using FRP plates generally occurs at the interface between FRP plate and the beam. Therefore, in order to prevent brittle rupture and improve the ductility of the system, this research was performed by using Aluminum and Titanium materials between the two different structural systems. The research also aims to provide various strengthening/retrofitting methods for RC beam structures and to conduct a preliminary analysis of the demands on the structural systems. This was achieved by estimation using the experimental data from this research to identify a flexural capacity for the systems. Ultimately, the preliminary analysis of current study showed that the flexural capacity and system demand ductility was significantly improved by the systems inserted with Aluminum and Titanium anchor plates. Further verification of the experimental research is currently on its way to develop a new or reliable design guideline to retrofit/strengthen the concrete-FRP structural system can be evaluated.
Abstract: A study concerning the photocatalytic decolourization
of Congo red (CR) dye, over artificial UV irradiation is presented.
Photocatalysts based on a commercial titanium dioxide (TiO2)
modified with transition metals (Ni, Cu and Zn) were used. The
dopage method used was wet impregnation. A TiO2 sample without
salt was subjected to the same hydrothermal treatment to be used as
reference. Congo red solutions to several pH conditions (natural and
basic) were used to evaluate photocatalytic performance of each
doped catalysts. Photodecolourization percentage was measured
spectrofotrometically after 3 h of treatment to 499 nm as response
variable. Kinetics investigations of photodegradation indicated that
reactions obey to Langmuir-Hinshelwood model and pseudo–first
order law. The rate constant studies of photocatalytic decolourization
reactions for Zn–TiO2 and Cu–TiO2 photocatalysts indicated that in
all cases the rate constant of the reaction was higher than that of TiO2
undoped. These results show that nature of the metal modifying the
TiO2 influence on the efficiency of the photocatalyst evaluated in
process. Ni does not present an additional effect compared with TiO2,
while Zn enhances the photoactivity due to its electronic properties.
Abstract: An implant elicits a biological response in the
surrounding tissue which determines the acceptance and long-term
function of the implant. Dental implants have become one of the
main therapy methods in clinic after teeth lose. A successful implant
is in contact with bone and soft tissue represent by fibroblasts. In our
study we focused on the interaction between six different chemically
and physically modified titanium implants (Tis-MALP, Tis-O, Tis-
OA, Tis-OPAAE, Tis-OZ, Tis-OPAE) with alveolar fibroblasts as
well as with five type of microorganisms (S. epidermis, S.mutans, S.
gordonii, S. intermedius, C.albicans). The analysis of microorganism
adhesion was determined by CFU (colony forming unite) and biofilm
formation. The presence of α3β1 and vinculin expression on alveolar
fibroblasts was demonstrated using phospho specific cell based
ELISA (PACE). Alveolar fibroblasts have the highest expression of
these proteins on Tis-OPAAE and Tis-OPAE. It corresponds with
results from bacterial adhesion and biofilm formation and it was
related to the lowest production of collagen I by alveolar fibroblasts
on Tis-OPAAE titanium disc.
Abstract: This study aimed to present the mechanical
performance evaluation of the dynamic hip screw (DHS) for
trochanteric fracture by means of finite element method. The
analyses were performed based on stainless steel and titanium
implant material definitions at various stages of bone healing and
including implant removal. The assessment of the mechanical
performance used two parameters, von Mises stress to evaluate the
strength of bone and implant and elastic strain to evaluate fracture
stability. The results show several critical aspects of dynamic hip
screw for trochanteric fracture stabilization. In the initial stage of
bone healing process, partial weight bearing should be applied to
avoid the implant failure. In the late stage of bone healing, stainless
steel implant should be removed.
Abstract: Nanophotocatalysts such as titanium (TiO2), zinc (ZnO), and iron (Fe2O3) oxides can be used in organic pollutants oxidation, and in many other applications. But among the challenges for technological application (scale-up) of the nanotechnology scientific developments two aspects are still little explored: research on environmental risk of the nanomaterials preparation methods, and the study of nanomaterials properties and/or performance variability. The environmental analysis was performed for six different methods of ZnO nanoparticles synthesis, and showed that it is possible to identify the more environmentally compatible process even at laboratory scale research. The obtained ZnO nanoparticles were tested as photocatalysts, and increased the degradation rate of the Rhodamine B dye up to 30 times.
Abstract: This paper deals optimized model to investigate the
effects of peak current, pulse on time and pulse off time in EDM performance on material removal rate of titanium alloy utilizing copper tungsten as electrode and positive polarity of the electrode. The experiments are carried out on Ti6Al4V. Experiments were
conducted by varying the peak current, pulse on time and pulse off time. A mathematical model is developed to correlate the influences of these variables and material removal rate of workpiece. Design of
experiments (DOE) method and response surface methodology
(RSM) techniques are implemented. The validity test of the fit and adequacy of the proposed models has been carried out through
analysis of variance (ANOVA). The obtained results evidence that as
the material removal rate increases as peak current and pulse on time
increases. The effect of pulse off time on MRR changes with peak ampere. The optimum machining conditions in favor of material removal rate are verified and compared. The optimum machining
conditions in favor of material removal rate are estimated and verified with proposed optimized results. It is observed that the developed model is within the limits of the agreeable error (about
4%) when compared to experimental results. This result leads to desirable material removal rate and economical industrial machining to optimize the input parameters.
Abstract: Titanium gels doped with water-soluble cationic porphyrin were synthesized by the sol–gel polymerization of Ti (OC4H9)4. In this work we investigate the spectroscopic properties along with SEM images of tetra carboxyl phenyl porphyrin when incorporated into porous matrix produced by the sol–gel technique.
Abstract: An ecofriendly Citrus paradisipeel extract mediated synthesis of TiO2 nanoparticles is reported under sonication. U.V.-vis, Transmission electron microscopy, Dynamic light scattering, and X-ray analyses are performed to characterize the formation of TiO2 nanoparticles. It is almost spherical in shape, having a size of 60–140 nm and the XRD peaks at 2θ = 25.363° confirm the characteristic facets for anatase form. The synthesized nanocatalyst is highly active in the decomposition of methyl orange (64 mg/L) in sunlight (~73%) for 2.5h.
Abstract: Titanium alloys like the modern alloy Ti 6Al 2Sn 4Zr 6Mo (Ti-6246) combine excellent specific mechanical properties and corrosion resistance. On the other hand,due to their material characteristics, machining of these alloys is difficult to perform. The aim of the current study is the analyses of wear mechanisms of coated cemented carbide tools applied in orthogonal cutting experiments of Ti-6246 alloy. Round bars were machined with standard coated tools in dry conditions on a CNC latheusing a wide range of cutting speeds and cutting depths. Tool wear mechanisms were afterwards investigated by means of stereo microscopy, optical microscopy, confocal microscopy and scanning electron microscopy. Wear mechanisms included fracture of the tool tip (total failure) and abrasion. Specific wear features like crater wear, micro cracks and built-up edgeformation appeared depending of the mechanical and thermal conditions generated in the workpiece surface by the cutting action.
Abstract: Titanium nitride (TiN) has been synthesized using the
sheet plasma negative ion source (SPNIS). The parameters used for
its effective synthesis has been determined from previous
experiments and studies. In this study, further enhancement of the
deposition rate of TiN synthesis and advancement of the SPNIS
operation is presented. This is primarily achieved by the addition of
Sm-Co permanent magnets and a modification of the configuration in
the TiN deposition process. The magnetic enhancement is aimed at
optimizing the sputtering rate and the sputtering yield of the process.
The Sm-Co permanent magnets are placed below the Ti target for
better sputtering by argon. The Ti target is biased from –250V to –
350V and is sputtered by Ar plasma produced at discharge current of
2.5–4A and discharge potential of 60–90V. Steel substrates of
dimensions 20x20x0.5mm3 were prepared with N2:Ar volumetric
ratios of 1:3, 1:5 and 1:10. Ocular inspection of samples exhibit
bright gold color associated with TiN. XRD characterization
confirmed the effective TiN synthesis as all samples exhibit the (200)
and (311) peaks of TiN and the non-stoichiometric Ti2N (220) facet.
Cross-sectional SEM results showed increase in the TiN deposition
rate of up to 0.35μm/min. This doubles what was previously obtained
[1]. Scanning electron micrograph results give a comparative
morphological picture of the samples. Vickers hardness results gave
the largest hardness value of 21.094GPa.
Abstract: This paper reports the fatigue crack growth behaviour
of gas tungsten arc, electron beam and laser beam welded Ti-6Al-4V
titanium alloy. Centre cracked tensile specimens were prepared to
evaluate the fatigue crack growth behaviour. A 100kN servo
hydraulic controlled fatigue testing machine was used under constant
amplitude uniaxial tensile load (stress ratio of 0.1 and frequency of
10 Hz). Crack growth curves were plotted and crack growth
parameters (exponent and intercept) were evaluated. Critical and
threshold stress intensity factor ranges were also evaluated. Fatigue
crack growth behaviour of welds was correlated with mechanical
properties and microstructural characteristics of welds. Of the three
joints, the joint fabricated by laser beam welding exhibited higher
fatigue crack growth resistance due to the presence of fine lamellar
microstructure in the weld metal.
Abstract: The study of effect of laser scanning speed on
material efficiency in Ti6Al4V application is very important because unspent powder is not reusable because of high temperature oxygen
pick-up and contamination. This study carried out an extensive study
on the effect of scanning speed on material efficiency by varying the
speed between 0.01 to 0.1m/sec. The samples are wire brushed and
cleaned with acetone after each deposition to remove un-melted
particles from the surface of the deposit. The substrate is weighed before and after deposition. A formula was developed to calculate the
material efficiency and the scanning speed was compared with the
powder efficiency obtained. The results are presented and discussed.
The study revealed that the optimum scanning speed exists for this study at 0.01m/sec, above and below which the powder efficiency
will drop
Abstract: Copolymerization of ethylene with 1-hexene was
carried out using two ansa-fluorenyl titanium derivative complexes.
The substituent effect on the catalytic activity, monomer reactivity
ratio and polymer property was investigated. It was found that the
presence of t-Bu groups on fluorenyl ring exhibited remarkable
catalytic activity and produced polymer with high molecular weight.
However, these catalysts produce polymer with narrow molecular
weight distribution, indicating the characteristic of single-site
metallocene catalyst. Based on 13C NMR, we can observe that
monomer reactivity ratio was affected by catalyst structure. The rH
values of complex 2 were lower than that of complex 1 which might
be result from the higher steric hindrance leading to a reduction of 1-
hexene insertion step.
Abstract: Highly ordered arrays of TiO2 nanotubes (TiNTs) were grown vertically on Ti foil by electrochemical anodization. We controlled the lengths of these TiNTs from 2.4 to 26.8 ¶üÇóμm while varying the water contents (1, 3, and 6 wt%) of the electrolyte in ethylene glycol in the presence of 0.5 wt% NH4F with anodization for various applied voltages (20–80 V), periods (10–240 min) and temperatures (10–30 oC). For vertically aligned TiNT arrays, not only the increase in their tube lengths, but also their geometric (wall thickness and surface roughness) and crystalline structure lead to a significant influence on photocatalytic activity. The length optimization for methylene blue (MB) photodegradation was 18 μm. Further extending the TiNT length yielded lower photocatalytic activity presumably related to the limited MB diffusion and light-penetration depth into the TiNT arrays. The results indicated that a maximum MB photodegradation rate was obtained for the discrete anatase TiO2 nanotubes with thick and rough walls.
Abstract: A thin coating of hexamethyldisiloxane and subsequent O2-plasma treatment was performed on mirror-polished titanium in order to regulate the wide range of wettability including 106 and almost 0 degrees of contact angles. The adsorption behavior of
fibronectin and albumin in both individual and competitive mode,
and initial attachment of fibroblasts and osteoblasts were investigated.
Individually, fibronectin adsorption showed a biphasic inclination, whereas albumin showed greater adsorption to hydrophobic surfaces.
In competitive mode, in solution containing both fibronectin and albumin, fibronectin showed greater adsorption on hydrophilic
surfaces, whereas Alb predominantly adsorbed on hydrophobic
surfaces. Initial attachment of both cells increased with increase in
surface wettability, in particular, on super-hydrophilic surface, which
correlated well with fibronectin adsorption in competitive mode.
These results suggest that a cold plasma-surface modification enabled
to regulate the surface wettability, and fibronectin adsorption may be
responsible for increasing cell adhesion on hydrophilic surfaces in a
body fluid
Abstract: Graphene-metal contact resistance limits the performance of graphene-based electrical devices. In this work, we have fabricated both graphene field-effect transistors (GFET) and transfer length measurement (TLM) test devices with titanium contacts. The purpose of this work is to compare the contact resistances that can be numerically extracted from the GFETs and measured from the TLM structures. We also provide a brief review of the work done in the field to solve the contact resistance problem.
Abstract: Adhesively bonded joints are preferred over the
conventional methods of joining such as riveting, welding, bolting
and soldering. Some of the main advantages of adhesive joints
compared to conventional joints are the ability to join dissimilar
materials and damage-sensitive materials, better stress distribution,
weight reduction, fabrication of complicated shapes, excellent
thermal and insulation properties, vibration response and enhanced
damping control, smoother aerodynamic surfaces and an
improvement in corrosion and fatigue resistance. This paper presents
the behavior of adhesively bonded joints subjected to combined
thermal loadings, using the numerical methods. The joint
configuration considers aluminum as central adherend with six
different outer adherends including aluminum, steel, titanium, boronepoxy,
unidirectional graphite-epoxy and cross-ply graphite-epoxy
and epoxy-based adhesives. Free expansion of the joint in x
direction was permitted and stresses in adhesive layer and interfaces
calculated for different adherends.