Abstract: The use of Flexible AC Transmission System
(FACTS) devices in a power system can potentially overcome
limitations of the present mechanically controlled transmission
system. Also, the advance of technology makes possible to include
new energy storage devices in the electrical power system. The
integration of Superconducting Magnetic Energy Storage (SMES)
into Static Synchronous Compensator (STATCOM) can lead to
increase their flexibility in improvement of power system dynamic
behaviour by exchanging both active and reactive powers with power
grids. This paper describes structure and behaviour of SMES,
specifications and performance principles of the STATCOM/SMES
compensator. Moreover, the benefits and effectiveness of integrated
SMES with STATCOM in power systems is presented. Also, the
performance of the STATCOM/SMES compensator is evaluated
using an IEEE 3-bus system through the dynamic simulation by
PSCAD/EMTDC software.
Abstract: High Voltage Direct Current (HVDC) power
transmission is employed to move large amounts of electric power.
There are several possibilities to enhance the transient stability in a
power system. One adequate option is by using the high
controllability of the HVDC if HVDC is available in the system. This
paper presents a control technique for HVDC to enhance the transient
stability. The strategy controls the power through the HVDC to help
make the system more transient stable during disturbances. Loss of
synchronism is prevented by quickly producing sufficient
decelerating energy to counteract accelerating energy gained during.
In this study, the power flow in the HVDC link is modulated with the
addition of an auxiliary signal to the current reference of the rectifier
firing angle controller. This modulation control signal is derived from
speed deviation signal of the generator utilizing a PD controller; the
utilization of a PD controller is suitable because it has the property of
fast response. The effectiveness of the proposed controller is
demonstrated with a SMIB test system.
Abstract: Implementation of advanced technologies requires
sophisticated instruments that deal with the operation, control,
restoration and protection of rapidly growing power system network
under normal and abnormal conditions. Presently, the applications of
Phasor Measurement Unit (PMU) are widely found in real time
operation, monitoring, controlling and analysis of power system
network as it eliminates the various limitations of supervisory control
and data acquisition system (SCADA) conventionally used in power
system. The use of PMU data is very rapidly increasing its
importance for online and offline analysis. Wide area measurement
system (WAMS) is developed as new technology by use of multiple
PMUs in power system. The present paper proposes a model of
Matlab based PMU using Discrete Fourier Transform (DFT)
algorithm and evaluation of its operation under different
contingencies. In this paper, PMU based two bus system having
WAMS network is presented as a case study.
Abstract: Flexible AC Transmission Systems (FACTS) is
granting a new group of advanced power electronic devices emerging
for enhancement of the power system performance. Unified Power
Flow Controller (UPFC) is a recent version of FACTS devices for
power system applications. The back-up energy supply system
incorporated with UPFC is providing a complete control of real and
reactive power at the same time and hence is competent to improve
the performance of an electrical power system. In this article, backup
energy supply unit such as superconducting magnetic energy storage
(SMES) is integrated with UPFC. In addition, comparative
exploration of UPFC–battery, UPFC–UC and UPFC–SMES
performance is evaluated through the vibrant simulation by using
MATLAB/Simulink software.
Abstract: This paper presents a methodology using
Gravitational Search Algorithm for optimal placement of Phasor
Measurement Units (PMUs) in order to achieve complete
observability of the power system. The objective of proposed
algorithm is to minimize the total number of PMUs at the power
system buses, which in turn minimize installation cost of the PMUs.
In this algorithm, the searcher agents are collection of masses which
interact with each other using Newton’s laws of gravity and motion.
This new Gravitational Search Algorithm based method has been
applied to the IEEE 14-bus, IEEE 30-bus and IEEE 118-bus test
systems. Case studies reveal optimal number of PMUs with better
observability by proposed method.
Abstract: At present, the evaluation of voltage stability
assessment experiences sizeable anxiety in the safe operation of
power systems. This is due to the complications of a strain power
system. With the snowballing of power demand by the consumers
and also the restricted amount of power sources, therefore, the system
has to perform at its maximum proficiency. Consequently, the
noteworthy to discover the maximum ability boundary prior to
voltage collapse should be undertaken. A preliminary warning can be
perceived to evade the interruption of power system’s capacity. The
effectiveness of line voltage stability indices (LVSI) is differentiated
in this paper. The main purpose of the indices used is to predict the
proximity of voltage instability of the electric power system. On the
other hand, the indices are also able to decide the weakest load buses
which are close to voltage collapse in the power system. The line
stability indices are assessed using the IEEE 14 bus test system to
validate its practicability. Results demonstrated that the implemented
indices are practically relevant in predicting the manifestation of
voltage collapse in the system. Therefore, essential actions can be
taken to dodge the incident from arising.
Abstract: This paper investigates the joint effect of the
interconnected (n,k)-star network topology and Multi-Agent
automated control on restoration and reconfiguration of power
systems. With the increasing trend in development in Multi-Agent
control technologies applied to power system reconfiguration
in presence of faulty components or nodes. Fault tolerance is
becoming an important challenge in the design processes of the
distributed power system topology. Since the reconfiguration of a
power system is performed by agent communication, the (n,k)-star
interconnected network topology is studied and modeled in this
paper to optimize the process of power reconfiguration. In this paper,
we discuss the recently proposed (n,k)-star topology and examine its
properties and advantages as compared to the traditional multi-bus
power topologies. We design and simulate the topology model for
distributed power system test cases. A related lemma based on the
fault tolerance and conditional diagnosability properties is presented
and proved both theoretically and practically. The conclusion is
reached that (n,k)-star topology model has measurable advantages
compared to standard bus power systems while exhibiting fault
tolerance properties in power restoration, as well as showing
efficiency when applied to power system route discovery.
Abstract: Ancillary services are support services which are
essential for humanizing and enhancing the reliability and security of
the electric power system. Reactive power ancillary service is one of
the important ancillary services in a restructured electricity market
which determines the cost of supplying ancillary services and finding
of how this cost would change with respect to operating decisions.
This paper presents a new formation that can be used to minimize the
Independent System Operator (ISO)’s total payment for reactive
power ancillary service. The modified power flow tracing algorithm
estimates the availability of reserve reactive power for ancillary
service. In order to find optimum reactive power dispatch,
Biogeography based optimization method (BPO) is proposed. Market
Reactive Clearing Price (MRCP) is then estimated and it encourages
generator companies (GENCOs) to participate in an ancillary service.
Finally, optimal weighting factor and real time utilization factor of
reactive power give the minimum ISO’s total payment. The
effectiveness of proposed design is verified using IEEE 30 bus
system.
Abstract: Current transformers (CTs) are used to transform large primary currents to a small secondary current. Since most standard equipment’s are not designed to handle large primary currents the CTs have an important part in any electrical system for the purpose of Metering and Protection both of which are integral in Power system. Now a days due to advancement in solid state technology, the operation times of the protective relays have come to a few cycles from few seconds. Thus, in such a scenario it becomes important to study the transient response of the current transformers as it will play a vital role in the operating of the protective devices.
This paper shows the steady state and transient behavior of current transformers and how it changes with change in connected burden. The transient and steady state response will be captured using the data acquisition software LabVIEW. Analysis is done on the real time data gathered using LabVIEW. Variation of current transformer characteristics with changes in burden will be discussed.
Abstract: Power quality has become a very important issue recently due to the impact on electricity suppliers, equipment manufacturers and customers. Power quality is described as the variation of voltage, current and frequency in a power system. Voltage magnitude is one of the major factors that determine the quality of power. Indeed, custom power technology, the low-voltage counterpart of the more widely known flexible ac transmission system (FACTS) technology, aimed at high-voltage power transmission applications, has emerged as a credible solution to solve many problems relating to power quality problems. There are various power quality problems such as voltage sags, swells, flickers, interruptions and harmonics etc. Active Power Filter (APF) is one of the custom power devices and can mitigate harmonics, reactive power and unbalanced load currents originating from load side. In this study, an extensive review of APF studies, the advantages and disadvantages of each introduced methods are presented. The study also helps the researchers to choose the optimum control techniques and power circuit configuration for APF applications.
Abstract: The advent of Flexible AC Transmission Systems (FACTS) is giving rise to a new family of power electronic equipment emerging for controlling and optimizing the performance of power system, e.g. STATCOM. Static synchronous Compensator (STATCOM) is a commonly used FACTS device and has been successfully applied in power systems. In this sense, superconducting magnetic energy storage (SMES) in integration with a static synchronous compensator (STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper the structure and characteristics of the STATCOM/SMES is proposed. In addition, using a proper control scheme, STATCOM/ SMES is tested on an IEEE 3-bus system and more effective performance of the presented STATCOM/SMES compensator is evaluated with alone STATCOM through the dynamic simulation by using PSCAD/EMTDC software.
Abstract: This paper presents a nonparametric identification of
continuous-time nonlinear systems by using a Gaussian process
(GP) model. The GP prior model is trained by artificial bee colony
algorithm. The nonlinear function of the objective system is estimated
as the predictive mean function of the GP, and the confidence
measure of the estimated nonlinear function is given by the predictive
covariance of the GP. The proposed identification method is applied
to modeling of a simplified electric power system. Simulation results
are shown to demonstrate the effectiveness of the proposed method.
Abstract: In this paper, an investigation into the use of modified Genetic Algorithm optimized SSSC based controller to aid damping of low frequency inter-area oscillations in power systems is presented. Controller design is formulated as a nonlinear constrained optimization problem and modified Genetic Algorithm (MGA) is employed to search for the optimal controller parameters. For evaluation of effectiveness and robustness of proposed controllers, the performance was tested on multi-machine system subjected to different disturbances, loading conditions and system parameter variations. Simulation results are presented to show the fine performance of the proposed SSSC controller in damping the critical modes without significantly deteriorating the damping characteristics of other modes in multi-machine power system.
Abstract: In this paper the application of a hierarchical fuzzy system (HFS) based on MPSS and SVC in multi-machine environment is studied. Also the effect of communication lines active power variance signal between two ΔPTie-line regions, as one of the inputs of hierarchical fuzzy multi-input PSS and SVC (HFMPSS & SVC), on the increase of low frequency oscillation damping is examined. In the MPSS, to have better efficiency an auxiliary signal of reactive power deviation (ΔQ) is added with ΔP+ Δω input type PSS. The number of rules grows exponentially with the number of variables in a classic fuzzy system. To reduce the number of rules the HFS consists of a number of low-dimensional fuzzy systems in a hierarchical structure. Phasor model of SVC is described and used in this paper. The performances of MPSS and ΔPTie-line based HFMPSS and also the proposed method in damping inter-area mode of oscillation are examined in response to disturbances. The efficiency of the proposed model is examined by simulating a four-machine power system. Results show that the proposed method is performing satisfactorily within the whole range of disturbances and reduces the cost of system.
Abstract: Reactive power limit of power system is one of the major causes of voltage instability. The only way to save the system from voltage instability is to reduce the reactive power load or add additional reactive power to reaching the point of voltage collapse. In recent times, the application of FACTS devices is a very effective solution to prevent voltage instability due to their fast and very flexible control. In this paper, voltage stability assessment with SVC and TCSC devices is investigated and compared in the modified IEEE 30-bus test system. The fast voltage stability indicator (FVSI) is used to identify weakest bus and to assess the voltage stability of power system.
Abstract: Restructuring of Electricity supply industry introduced many issues such as transmission pricing, transmission loss allocation and congestion management. Many methodologies and algorithms were proposed for addressing these issues. In this paper a power flow tracing based method is proposed which involves Matrices methodology for the transmission usage and loss allocation for generators and demands. This method provides loss allocation in a direct way because all the computation is previously done for usage allocation. The proposed method is simple and easy to implement in a large power system. Further it is less computational because it requires matrix inversion only a single time. After usage and loss allocation cooperative game theory is applied to results for finding efficient economic signals. Nucleolus and Shapely value approach is used for optimal allocation of results. Results are shown for the IEEE 6 bus system and IEEE 14 bus system.
Abstract: This paper describes the power-system stability improvement by a static synchronous compensator (STATCOM) based damping controller with Differential evolution (DE) algorithm is used to find out the optimal controller parameters. The present study considered both local and remote signals with associated time delays. The performances of the proposed controllers have been compared with different disturbances for both single-machine infinite bus power system and multi-machine power system. The performance of the proposed controllers with variations in the signal transmission delays has also been investigated. To show the effectiveness and robustness of the proposed controller the Simulation results are presented under different disturbances and loading conditions.
Abstract: Power-system stability improvement by simultaneous tuning of power system stabilizer (PSS) and a Static Var Compensator (SVC) based damping controller is thoroughly investigated in this paper. Both local and remote signals with associated time delays are considered in the present study. The design problem of the proposed controller is formulated as an optimization problem, and differential evolution (DE) algorithm is employed to search for the optimal controller parameters. The performances of the proposed controllers are evaluated under different disturbances for both single-machine infinite bus power system and multi-machine power system. The performance of the proposed controllers with variations in the signal transmission delays has also been investigated. The proposed stabilizers are tested on a weakly connected power system subjected to different disturbances. Nonlinear simulation results are presented to show the effectiveness and robustness of the proposed control schemes over a wide range of loading conditions and disturbances. Further, the proposed design approach is found to be robust and improves stability effectively even under small disturbance conditions.
Abstract: Power quality is used to describe the degree of consistency of electrical energy expected from generation source to point of use. The term power quality refers to a wide variety of electromagnetic phenomena that characterize the voltage and current at a given time and at a given location on the power system. Power quality problems can be defined as problem that results in failure of customer equipments, which manifests itself as an economic burden to users, or produces negative impacts on the environment. Voltage stability, power factor, harmonics pollution, reactive power and load unbalance are some of the factors that affect the consistency or the quality level. This research proposal proposes to investigate and analyze the causes and effects of power quality to homes and industries in Sarawak. The increasing application of electronics equipment used in the industries and homes has caused a big impact on the power quality. Many electrical devices are now interconnected to the power network and it can be observed that if the power quality of the network is good, then any loads connected to it will run smoothly and efficiently. On the other hand, if the power quality of the network is bad, then loads connected to it will fail or may cause damage to the equipments and reduced its lifetime. The outcome of this research will enable better and novel solutions of poor power quality to small industries and reduce damage of electrical devices and products in the industries.
Abstract: In power system protection, the need to know the load
current together with the fault level detected by a relay is important.
This is due to the fact that the relay is required to isolate the
equipment being protected if a fault is present and keep the breaker
associated with it closed if the current level is lower than the
maximum load level. This is not an issue for a radial system. This is
not the same however in a looped power system. In a looped power
system, the isolation of an equipment system will contribute to a
topology change. The change in the power system topology will then
influence or change the maximum load current and the fault level
detected by each relay. In this paper, a method of data collection for
changing topology using matlab and sim-power will be presented.
The method will take into consideration the change in topology and
collect data for each possible topology.