Abstract: Among the various methods of treatment, advanced oxidation processes (AOP) are the most promising ones. In this study, Peroxi Electrocoagulation Process (PEP) was investigated for the treatment of detergent wastewater. The process was compared with electrooxidation treatment. The results showed that chemical oxygen demand (COD) was high 7584 mgO2.L-1, while the biochemical oxygen demand was low (250 mgO2.L-1). This wastewater was hardly biodegradable. Electrochemical process was carried out for the removal of detergent using a glass reactor with a volume of 1 L and fitted with three electrodes. A direct current (DC) supply was used. Samples were taken at various current density (0.0227 A/cm2 to 0.0378 A/cm2) and reaction time (1-2-3-4 and 5 hour). Finally, the COD was determined. The results indicated that COD removal efficiency of PEP was observed to increase with current intensity and reached to 77% after 5 h. The highest removal efficiency was observed after 5 h of treatment.
Abstract: Direct methanol fuel cells (DMFCs) are considered to be one of the most promising candidates for portable and stationary applications in the view of their advantages such as high energy density, easy manipulation, high efficiency and they operate with liquid fuel which could be used without requiring any fuel-processing units. Electrolyte membrane of DMFC plays a key role as a proton conductor as well as a separator between electrodes. Increasing concern over environmental protection, biopolymers gain tremendous interest owing to their eco-friendly bio-degradable nature. Pectin is a natural anionic polysaccharide which plays an essential part in regulating mechanical behavior of plant cell wall and it is extracted from outer cells of most of the plants. The aim of this study is to develop and demonstrate pectin based polymer composite membranes as methanol impermeable polymer electrolyte membranes for DMFCs. Pectin based nanocomposites membranes are prepared by solution-casting technique wherein pectin is blended with chitosan followed by the addition of optimal amount of sulphonic acid modified Titanium dioxide nanoparticle (S-TiO2). Nanocomposite membranes are characterized by Fourier Transform-Infra Red spectroscopy, Scanning electron microscopy, and Energy dispersive spectroscopy analyses. Proton conductivity and methanol permeability are determined into order to evaluate their suitability for DMFC application. Pectin-chitosan blends endow with a flexible polymeric network which is appropriate to disperse rigid S-TiO2 nanoparticles. Resulting nanocomposite membranes possess adequate thermo-mechanical stabilities as well as high charge-density per unit volume. Pectin-chitosan natural polymeric nanocomposite comprising optimal S-TiO2 exhibits good electrochemical selectivity and therefore desirable for DMFC application.
Abstract: Functional electrical stimulation (FES) is a commonly used technique in rehabilitation and often associated with rapid muscle fatigue which becomes the limiting factor in its applications. The objective of this study is to investigate the effects on the onset of fatigue of conventional synchronous stimulation, as well as asynchronous stimulation that mimic voluntary muscle activation targeting different motor units which are activated sequentially or randomly via multiple pairs of stimulation electrodes. We investigate three different approaches with various electrode configurations, as well as different patterns of stimulation applied to the gastrocnemius muscle: Conventional Synchronous Stimulation (CSS), Asynchronous Sequential Stimulation (ASS) and Asynchronous Random Stimulation (ARS). Stimulation was applied repeatedly for 300 ms followed by 700 ms of no-stimulation with 40 Hz effective frequency for all protocols. Ten able-bodied volunteers (28±3 years old) participated in this study. As fatigue indicators, we focused on the analysis of Normalized Fatigue Index (NFI), Fatigue Time Interval (FTI) and pre-post Twitch-Tetanus Ratio (ΔTTR). The results demonstrated that ASS and ARS give higher NFI and longer FTI confirming less fatigue for asynchronous stimulation. In addition, ASS and ARS resulted in higher ΔTTR than conventional CSS. In this study, we proposed a randomly distributed stimulation method for the application of FES and investigated its suitability for reducing muscle fatigue compared to previously applied methods. The results validated that asynchronous stimulation reduces fatigue, and indicates that random stimulation may improve fatigue resistance in some conditions.
Abstract: Germanium Telluride based quaternary thin film switching devices with composition Ge15In5Te56Ag24, have been deposited in sandwich geometry on glass substrate with aluminum as top and bottom electrodes. The bulk glassy form of the said composition is prepared by melt quenching technique. In this technique, appropriate quantity of elements with high purity are taken in a quartz ampoule and sealed under a vacuum of 10-5 mbar. Then, it is allowed to rotate in a horizontal rotary furnace for 36 hours to ensure homogeneity of the melt. After that, the ampoule is quenched into a mixture of ice - water and NaOH to get the bulk ingot of the sample. The sample is then coated on a glass substrate using flash evaporation technique at a vacuum level of 10-6 mbar. The XRD report reveals the amorphous nature of the thin film sample and Energy - Dispersive X-ray Analysis (EDAX) confirms that the film retains the same chemical composition as that of the base sample. Electrical switching behavior of the device is studied with the help of Keithley (2410c) source-measure unit interfaced with Lab VIEW 7 (National Instruments). Switching studies, mainly SET (changing the state of the material from amorphous to crystalline) operation is conducted on the thin film form of the sample. This device is found to manifest memory switching as the device remains 'ON' even after the removal of the electric field. Also it is found that amorphous Ge15In5Te56Ag24 thin film unveils clean memory type of electrical switching behavior which can be justified by the absence of fluctuation in the I-V characteristics. The I-V characteristic also reveals that the switching is faster in this sample as no data points could be seen in the negative resistance region during the transition to on state and this leads to the conclusion of fast phase change during SET process. Scanning Electron Microscopy (SEM) studies are performed on the chosen sample to study the structural changes at the time of switching. SEM studies on the switched Ge15In5Te56Ag24 sample has shown some morphological changes at the place of switching wherein it can be explained that a conducting crystalline channel is formed in the device when the device switches from high resistance to low resistance state. From these studies it can be concluded that the material may find its application in fast switching Non-Volatile Phase Change Memory (PCM) Devices.
Abstract: In this paper, the design and evaluation of a handle for laparoscopic surgery is presented. The design of the handle is based on ergonomic principles and tries to avoid awkward postures for surgeons. The handle combines the so-called power-grip and accurate-grip in order to provide strength and accuracy in the performance of surgery. The handle is tested using both objective and subjective approaches. The objective approach uses motion capture techniques to obtain the angles of forearm, arm, wrist and hand. The muscular effort is obtained with electromyography electrodes. On the other hand, a subjective survey has been carried out using questionnaires. Results confirm that the handle is preferred by the majority of the surgeons.
Abstract: In this work new macroporous Ni electrodes modified
with Au nanoparticles for hydrogen production have been developed.
The supporting macroporous Ni electrodes have been obtained by
means of the electrodeposition at high current densities. Then, the Au
nanoparticles were synthesized and added to the electrode surface.
The electrocatalytic behaviour of the developed electrocatalysts was
studied by means of pseudo-steady-state polarization curves,
electrochemical impedance spectroscopy (EIS) and hydrogen
discharge curves. The size of the Au synthetized nanoparticles shows
a monomodal distribution, with a very sharp band between 10 and 50
nm. The characteristic parameters d10, d50 and d90 were 14, 20 and
31 nm respectively. From Tafel polarization data has been concluded
that the Au nanoparticles improve the catalytic activity of the
developed electrodes towards the HER respect to the macroporous Ni
electrodes. EIS permits to obtain the electrochemically active area by
means of the roughness factor value. All the developed electrodes
show roughness factor values in the same order of magnitude. From
the activation energy results it can be concluded that the Au
nanoparticles improve the intrinsic catalytic activity of the
macroporous Ni electrodes.
Abstract: In Jordan having deficit atmospheric precipitation, an
increase in water demand occurs during summer months. Jordan can
be regarded with a relatively high potential for wastewater recycling
and reuse. The main purpose of this paper was to investigate the
removal of total suspended solids (TSS) and chemical oxygen
demand (COD) for olive mill wastewater (OMW) by
electrocoagulation (EC) process. In the combination of
electrocoagulation by using coupled iron–aluminum electrodes, the
optimum working pH was found to be around 6. Results indicated
that the electrocoagulation process allowed removal of TSS and COD
of about 82.5% and 47.5%, respectively at 45 mA/cm2 after 70
minutes by using coupled iron–aluminum electrodes. It was
demonstrated that the maximum TSS and COD removals were
obtained at some optimum experimental parameters for current
density, pH, and reaction time.
Abstract: This paper outlines the basic installation and operation of magnetic inductive flow velocity sensors on large underground cooling water pipelines. Research on the effects of cathodic protection as well as into other factors that might influence the overall performance of the meter is presented in this paper. The experiments were carried out on an immersion type magnetic meter specially used for flow measurement of cooling water pipeline. An attempt has been made in this paper to outline guidelines that can ensure accurate measurement related to immersion type magnetic meters on underground pipelines.
Abstract: In order to detect and quantify the phenolic contents
of a wastewater with biosensors, two working electrodes based on
modified Poly(Pyrrole) films were fabricated. Enzyme horseradish
peroxidase was used as biomolecule of the prepared electrodes.
Various phenolics were tested at the biosensor. Phenol detection was
realized by electrochemical reduction of quinones produced by
enzymatic activity. Analytical parameters were calculated and the
results were compared with each other.
Abstract: This study models the use of transcutaneous electrical
nerve stimulation on skin with a disk electrode in order to simulate
tissue damage. The current density distribution above a disk electrode
is known to be a dynamic and non-uniform quantity that is intensified
at the edges of the disk. The non-uniformity is subject to change
through using various electrode geometries or stimulation methods.
One of these methods known as edge-retarded stimulation has shown
to reduce this edge enhancement. Though progress has been made in
modeling the behavior of a disk electrode, little has been done to test
the validity of these models in simulating the actual heat transfer
from the electrode. This simulation uses finite element software to
couple the injection of current from a disk electrode to heat transfer
described by the Pennesbioheat transfer equation. An example
application of this model is studying an experimental form of
stimulation, known as edge-retarded stimulation. The edge-retarded
stimulation method will reduce the current density at the edges of the
electrode. It is hypothesized that reducing the current density edge
enhancement effect will, in turn, reduce temperature change and
tissue damage at the edges of these electrodes. This study tests this
hypothesis as a demonstration of the capabilities of this model. The
edge-retarded stimulation proved to be safer after this simulation. It is
shown that temperature change and the fraction of tissue necrosis is
much greater in the square wave stimulation. These results bring
implications for changes of procedures in transcutaneous electrical
nerve stimulation and transcutaneous spinal cord stimulation as well.
Abstract: The radiation effect within the solid anode, electrolyte, and cathode SOFC layers problem has been investigated in this paper. Energy equation is solved by the Lattice Boltzmann method (LBM). The Rosseland method is used to model the radiative transfer in the electrodes. The Schuster-Schwarzschild method is used to model the radiative transfer in the electrolyte. Without radiative effect, the found results are in good agreement with those published. The obtained results show that the radiative effect can be neglected.
Abstract: Electrical discharge machining (EDM) is well
established machining technique mainly used to machine complex
geometries on difficult-to-machine materials and high strength
temperature resistant alloys. In the present research, the objective is
to study the shape of the electrode and establish the application of
liquid nitrogen in reducing distortion of the electrode during
electrical discharge machining of M2 grade high speed steel using
copper electrodes. Study of roundness was performed on the
electrode to observe the shape of the electrode for both conventional
EDM and EDM with cryogenically cooled electrode. Scanning
Electron Microscope (SEM) has been used to study the shape of
electrode tip. The effect of various parameters such as discharge
current and pulse on time has been studied to understand the behavior
of distortion of electrode. It has been concluded that the shape
retention is better in case of liquid nitrogen cooled electrode.
Abstract: Electromagnetic flow meter by measuring the varying of magnetic flux, which is related to the velocity of conductive flow, can measure the rate of fluids very carefully and precisely. Electromagnetic flow meter operation is based on famous Faraday's second Law. In these equipments, the constant magnetostatic field is produced by electromagnet (winding around the tube) outside of pipe and inducting voltage that is due to conductive liquid flow is measured by electrodes located on two end side of the pipe wall. In this research, we consider to 2-dimensional mathematical model that can be solved by numerical finite difference (FD) solution approach to calculate induction potential between electrodes. The fundamental concept to design the electromagnetic flow meter, exciting winding and simulations are come out by using MATLAB and PDE-Tool software. In the last stage, simulations results will be shown for improvement and accuracy of technical provision.
Abstract: Electric impedance imaging is a method of
reconstructing spatial distribution of electrical conductivity inside a
subject. In this paper, a new method of electrical impedance imaging
using eddy current is proposed. The eddy current distribution in the
body depends on the conductivity distribution and the magnetic field
pattern. By changing the position of magnetic core, a set of voltage
differences is measured with a pair of electrodes. This set of voltage
differences is used in image reconstruction of conductivity
distribution. The least square error minimization method is used as a
reconstruction algorithm. The back projection algorithm is used to
get two dimensional images. Based on this principle, a measurement
system is developed and some model experiments were performed
with a saline filled phantom. The shape of each model in the
reconstructed image is similar to the corresponding model,
respectively. From the results of these experiments, it is confirmed
that the proposed method is applicable in the realization of electrical
imaging.
Abstract: In situ observation of absorption spectral change of
heptil viologen cation radical (HV+.) was performed by slab optical
waveguide (SOWG) spectroscopy utilizing indium-tin-oxide (ITO)
electrodes. Synchronizing with electrochemical techniques, we
observed the adsorption process of HV+.on the ITO electrode. In this
study, we carried out the ITO-SOWG observations using KBr aqueous
solution containing different concentration of HV to investigate the
concentration dependent spectral change. A few specific absorption
bands, which indicated HV+.existed as both monomer and dimer on
ITO electrode surface with a monolayer or a few layers deposition,
were observed in UV-visible region. The change in the peak position
of the absorption spectra from adsorption species of HV+. were
correlated with the concentration of HV as well as the electrode
potential.
Abstract: Effect of temperature and light was investigated on a
thin film of organic semiconductor formyl-TIPPCu(II) deposited on a
glass substrate with preliminary evaporated gold electrodes. The
electrical capacitance and resistance of the fabricated device were
evaluated under the effect of temperature and light. The relative
capacitance of the fabricated sensor increased by 4.3 times by rising
temperature from 27 to 1870C, while under illumination up to 25000
lx, the capacitance of the Au/formyl-TIPPCu(II)/Au photo capacitive
sensor increased continuously by 13.2 times as compared to dark
conditions.
Abstract: Nuclear matrix protein 22 (NMP22) is a FDA approved
biomarker for bladder cancer. The objective of this study is to develop
a simple NMP22 immumosensor (NMP22-IMS) for accurate
measurement of NMP22. The NMP22-IMS was constructed with
NMP22 antibody immobilized on screen-printed carbon electrodes.
The construction procedures and antibody immobilization are simple.
Results showed that the NMP22-IMS has an excellent (r2³0.95)
response range (20 – 100 ng/mL). In conclusion, a simple and reliable
NMP22-IMS was developed, capable of precisely determining urine
NMP22 level.
Abstract: In this paper we introduce a novel method for
the characterization of synchronziation and coupling effects
in multivariate time series that can be used for the analysis
of EEG or ECoG signals recorded during epileptic seizures.
The method allows to visualize the spatio-temporal evolution
of synchronization and coupling effects that are characteristic
for epileptic seizures. Similar to other methods proposed for
this purpose our method is based on a regression analysis.
However, a more general definition of the regression together
with an effective channel selection procedure allows to use the
method even for time series that are highly correlated, which
is commonly the case in EEG/ECoG recordings with large
numbers of electrodes. The method was experimentally tested
on ECoG recordings of epileptic seizures from patients with
temporal lobe epilepsies. A comparision with the results from
a independent visual inspection by clinical experts showed
an excellent agreement with the patterns obtained with the
proposed method.
Abstract: The aim of this study was to remove the two principal
noises which disturb the surface electromyography signal
(Diaphragm). These signals are the electrocardiogram ECG artefact
and the power line interference artefact. The algorithm proposed
focuses on a new Lean Mean Square (LMS) Widrow adaptive
structure. These structures require a reference signal that is correlated
with the noise contaminating the signal. The noise references are
then extracted : first with a noise reference mathematically
constructed using two different cosine functions; 50Hz (the
fundamental) function and 150Hz (the first harmonic) function for
the power line interference and second with a matching pursuit
technique combined to an LMS structure for the ECG artefact
estimation. The two removal procedures are attained without the use
of supplementary electrodes. These techniques of filtering are
validated on real records of surface diaphragm electromyography
signal. The performance of the proposed methods was compared with
already conducted research results.
Abstract: In this paper we present a new multichannel high
voltage driver box to connect up to six MOEMS mirror devices to it that have resonant and also quasistatically driven actuating electrodes. It is possible to drive all resonant axes synchronously
while the amplitude of them can individually be controlled by separate microcontrollers that also operate the quasistatic axes.
Circuit simulations are compared with the measurements done on the
real system and also show the robust driving performance of a
MOEMS mirror.