Abstract: In this paper, a new efficient method for load balancing in low voltage distribution systems is presented. The proposed method introduces an improved Leap-frog method for optimization. The proposed objective function includes the difference between three phase currents, as well as two other terms to provide the integer property of the variables; where the latter are the status of the connection of loads to different phases. Afterwards, a new algorithm is supplemented to undertake the integer values for the load connection status. Finally, the method is applied to different parts of Tabriz low voltage network, where the results have shown the good performance of the proposed method.
Abstract: In this paper, we propose the Modified Synchronous Detection (MSD) Method for determining the reference compensating currents of the shunt active power filter under non sinusoidal voltages conditions. For controlling the inverter switching we used the PI regulator. The numerical simulation results, using Power System Blockset Toolbox PSB of Matlab, from a complete structure, are presented and discussed.
Abstract: The realization of current-mode quadrature oscillators
using current controlled current conveyor transconductance
amplifiers (CCCCTAs) and grounded capacitors is presented. The
proposed oscillators can provide 2 sinusoidal output currents with 90º
phase difference. It is enabled non-interactive dual-current control for
both the condition of oscillation and the frequency of oscillation.
High output impedances of the configurations enable the circuit to be
cascaded without additional current buffers. The use of only
grounded capacitors is ideal for integration. The circuit performances
are depicted through PSpice simulations, they show good agreement
to theoretical anticipation.
Abstract: In this paper, the two-dimensional stagger grid
interface pressure (SGIP) model has been generalized and presented
into three-dimensional form. For this purpose, various models of
surface tension force for interfacial flows have been investigated and
compared with each other. The VOF method has been used for
tracking the interface. To show the ability of the SGIP model for
three-dimensional flows in comparison with other models, pressure
contours, maximum spurious velocities, norm spurious flow
velocities and pressure jump error for motionless drop of liquid and
bubble of gas are calculated using different models. It has been
pointed out that SGIP model in comparison with the CSF, CSS and
PCIL models produces the least maximum and norm spurious
velocities. Additionally, the new model produces more accurate
results in calculating the pressure jumps across the interface for
motionless drop of liquid and bubble of gas which is generated in
surface tension force.
Abstract: In this paper, we explore the applicability of the Sinc-
Collocation method to a three-dimensional (3D) oceanography model.
The model describes a wind-driven current with depth-dependent
eddy viscosity in the complex-velocity system. In general, the
Sinc-based methods excel over other traditional numerical methods
due to their exponentially decaying errors, rapid convergence and
handling problems in the presence of singularities in end-points.
Together with these advantages, the Sinc-Collocation approach that
we utilize exploits first derivative interpolation, whose integration
is much less sensitive to numerical errors. We bring up several
model problems to prove the accuracy, stability, and computational
efficiency of the method. The approximate solutions determined by
the Sinc-Collocation technique are compared to exact solutions and
those obtained by the Sinc-Galerkin approach in earlier studies. Our
findings indicate that the Sinc-Collocation method outperforms other
Sinc-based methods in past studies.
Abstract: Current spectrums of a high power induction machine was calculated for the cases of full symmetry, static and dynamic eccentricity. The calculations involve integration of 93 electrical plus four mechanical ordinary differential equations. Electrical equations account for variable inductances affected by slotting and eccentricities. The calculations were followed by Fourier analysis of the stator currents in steady state operation. The paper presents the stator current spectrums in full symmetry, static and dynamic eccentricity cases, and demonstrates the harmonics present in each case. The effect of dynamic eccentricity is demonstrating via comparing the current spectrums related to dynamic eccentricity cases with the full symmetry one. The paper includes one case study, refers to dynamic eccentricity, to present the spectrum of the measured current and demonstrate the existence of the harmonics related to dynamic eccentricity. The zooms of current spectrums around the main slot harmonic zone are included to simplify the comparison and prove the existence of the dynamic eccentricity harmonics in both calculated and measured current spectrums.
Abstract: Short circuit currents plays a vital role in influencing the design and operation of equipment and power system and could not be avoided despite careful planning and design, good maintenance and thorough operation of the system. This paper discusses the short circuit analysis conducted in KSO briefly comprising of its significances, methods and results. A result sample of the analysis based on a single transformer is detailed in this paper. Furthermore, the results of the analysis and its significances were also discussed and commented.
Abstract: In the present study, position estimation of switched reluctance motor (SRM) has been achieved on the basis of the artificial neural networks (ANNs). The ANNs can estimate the rotor position without using an extra rotor position sensor by measuring the phase flux linkages and phase currents. Flux linkage-phase current-rotor position data set and supervised backpropagation learning algorithm are used in training of the ANN based position estimator. A 4-phase SRM have been used to verify the accuracy and feasibility of the proposed position estimator. Simulation results show that the proposed position estimator gives precise and accurate position estimations for both under the low and high level reference speeds of the SRM
Abstract: In the past many uneconomic solutions for limitation
and interruption of short-circuit currents in low power applications
have been introduced, especially polymer switch based on the
positive temperature coefficient of resistance (PCTR) concept.
However there are many limitations in the active material, which
consists of conductive fillers. This paper presents a significantly
improved and simplified approach that replaces the existing current
limiters with faster switching elements. Its elegance lies in the
remarkable simplicity and low-cost processes of producing the device
using polyaniline (PANI) doped with methane-sulfonic acid (MSA).
Samples characterized as lying in the metallic and critical regimes of
metal insulator transition have been studied by means of electrical
performance in the voltage range from 1V to 5 V under different
environmental conditions. Moisture presence is shown to increase the
resistivity and also improved its current limiting performance.
Additionally, the device has also been studied for electrical resistivity
in the temperature range 77 K-300 K. The temperature dependence of
the electrical conductivity gives evidence for a transport mechanism
based on variable range hopping in three dimensions.
Abstract: The designing of charge pump with high gain Op-
Amp is a challenging task for getting faithful response .Design of
high performance phase locked loop require ,a design of high
performance charge pump .We have designed a operational amplifier
for reducing the error caused by high speed glitch in a transistor and
mismatch currents . A separate Op-Amp has designed in 180 nm
CMOS technology by CADENCE VIRTUOSO tool. This paper
describes the design of high performance charge pump for GHz
CMOS PLL targeting orthogonal frequency division multiplexing
(OFDM) application. A high speed low power consumption Op-Amp
with more than 500 MHz bandwidth has designed for increasing the
speed of charge pump in Phase locked loop.
Abstract: This paper presents the study of induced currents and
temperature distribution in gear heated by induction process using 2D
finite element (FE) model. The model is developed by coupling
Maxwell and heat transfer equations into a multi-physics model. The
obtained results allow comparing the medium frequency (MF) and
high frequency (HF) cases and the effect of machine parameters on
the evolution of induced currents and temperature during heating.
The sensitivity study of the temperature profile is conducted and the
case hardness is predicted using the final temperature profile. These
results are validated using tests and give a good understanding of
phenomena during heating process.
Abstract: In nature, electromagnetic fields always appear like
atmosphere static electric field, the earth's static magnetic field and
the wide-rang frequency electromagnetic field caused by lightening.
However, besides natural electromagnetic fields (EMF), today human
beings are mostly exposed to artificial electromagnetic fields due to
technology progress and outspread use of electrical devices. To
evaluate nuisance of EMF, it is necessary to know field intensity for
every frequency which appears and compare it with allowed values.
Low frequency EMF-s around transmission and distribution lines are
time-varying quasi-static electromagnetic fields which have
conservative component of low frequency electrical field caused by
charges and eddy component of low frequency magnetic field caused
by currents. Displacement current or field delay are negligible, so
energy flow in quasi-static EMF involves diffusion, analog like heat
transfer. Electrical and magnetic field can be analyzed separately.
This paper analysis the numerical calculations in ELF-400 software
of EMF in distribution substation in shopping center. Analyzing the
results it is possible to specify locations exposed to the fields and
give useful suggestion to eliminate electromagnetic effect or reduce it
on acceptable level within the non-ionizing radiation norms and
norms of protection from EMF.
Abstract: This paper presents an optimal design of poly-phase induction motor using Quadratic Interpolation based Particle Swarm Optimization (QI-PSO). The optimization algorithm considers the efficiency, starting torque and temperature rise as objective function (which are considered separately) and ten performance related items including harmonic current as constraints. The QI-PSO algorithm was implemented on a test motor and the results are compared with the Simulated Annealing (SA) technique, Standard Particle Swarm Optimization (SPSO), and normal design. Some benchmark problems are used for validating QI-PSO. From the test results QI-PSO gave better results and more suitable to motor-s design optimization. Cµ code is used for implementing entire algorithms.
Abstract: This paper presents the mathematical model and
control strategy on DQ frame of shunt active power filter. The
structure of the shunt active power filter is the voltage source inverter
(VSI). The pulse width modulation (PWM) with PI controller is used
in the paper. The concept of DQ frame to apply with the shunt active
power filter is described. Moreover, the detail of the PI controller
design for two current loops and one voltage loop are fully explained.
The DQ axis with Fourier (DQF) method is applied to calculate the
reference currents on DQ frame. The simulation results show that the
control strategy and the design method presented in the paper can
provide the good performance of the shunt active power filter.
Moreover, the %THD of the source currents after compensation can
follow the IEEE Std.519-1992.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: An on-line condition monitoring method for transmission line is proposed using electrical circuit theory and IT technology in this paper. It is reasonable that the circuit parameters such as resistance (R), inductance (L), conductance (g) and capacitance (C) of a transmission line expose the electrical conditions and physical state of the line. Those parameters can be calculated from the linear equation composed of voltages and currents measured by synchro-phasor measurement technique at both end of the line. A set of linear voltage drop equations containing four terminal constants (A, B ,C ,D ) are mathematical models of the transmission line circuits. At least two sets of those linear equations are established from different operation condition of the line, they may mathematically yield those circuit parameters of the line. The conditions of line connectivity including state of connecting parts or contacting parts of the switching device may be monitored by resistance variations during operation. The insulation conditions of the line can be monitored by conductance (g) and capacitance(C) measurements. Together with other condition monitoring devices such as partial discharge, sensors and visual sensing device etc.,they may give useful information to monitor out any incipient symptoms of faults. The prototype of hardware system has been developed and tested through laboratory level simulated transmission lines. The test has shown enough evident to put the proposed method to practical uses.
Abstract: The paper presents coupled electromagnetic and
thermal field analysis of busbar system (of rectangular cross-section
geometry) submitted to short circuit conditions. The laboratory model
was validated against both analytical solution and experimental
observations. The considered problem required the computation of
the detailed distribution of the power losses and the heat transfer
modes. In this electromagnetic and thermal analysis, different
definitions of electric busbar heating were considered and compared.
The busbar system is a three phase one and consists of aluminum,
painted aluminum and copper busbar. The solution to the coupled
field problem is obtained using the finite element method and the
QuickField™ program. Experiments have been carried out using two
different approaches and compared with computed results.
Abstract: Attracting ferromagnetic forces between magnet and reaction rail provide the supporting force in Electromagnetic Suspension. Miniature maglev using permanent magnets and electromagnets is based on the idea to generate the nominal magnetic force by permanent magnets and superimpose the variable magnetic field required for stabilization by currents flowing through control windings in electromagnets. Permanent magnets with a high energy density have lower power losses with regard to supporting force and magnet weight. So the advantage of the maglev using electromagnets and permanent magnets is partially reduced by the power required to feed the remaining onboard supply system so that the overall onboard power is diminished as compared to that of the electromagnet. In this paper we proposed the how to design and control the miniature maglev and confirmed the feasibility of the levitation system using electromagnets and permanent magnets through the manufacturing the miniature maglev
Abstract: Most electrical distribution systems are incurring large
losses as the loads are wide spread, inadequate reactive power
compensation facilities and their improper control. A typical static
VAR compensator consists of capacitor bank in binary sequential
steps operated in conjunction with a thyristor controlled reactor of the
smallest step size. This SVC facilitates stepless control of reactive
power closely matching with load requirements so as to maintain
power factor nearer to unity. This type of SVC-s requiring a
appropriately controlled TCR. This paper deals with an air cored
reactor suitable for distribution transformer of 3phase, 50Hz, Dy11,
11KV/433V, 125 KVA capacity. Air cored reactors are designed,
built, tested and operated in conjunction with capacitor bank in five
binary sequential steps. It is established how the delta connected TCR
minimizes the harmonic components and the operating range for
various electrical quantities as a function of firing angle is
investigated. In particular firing angle v/s line & phase currents, D.C.
components, THD-s, active and reactive powers, odd and even triplen
harmonics, dominant characteristic harmonics are all investigated and
range of firing angle is fixed for satisfactory operation. The harmonic
spectra for phase and line quantities at specified firing angles are
given. In case the TCR is operated within the bound specified in this
paper established through simulation studies are yielding the best
possible operating condition particularly free from all dominant
harmonics.
Abstract: This article presents a current-mode quadrature
oscillator using differential different current conveyor (DDCC) and
voltage differencing transconductance amplifier (VDTA) as active
elements. The proposed circuit is realized fro m a non-inverting
lossless integrator and an inverting second order low-pass filter. The
oscillation condition and oscillation frequency can be
electronically/orthogonally controlled via input bias currents. The
circuit description is very simple, consisting of merely 1 DDCC, 1
VDTA, 1 grounded resistor and 3 grounded capacitors. Using only
grounded elements, the proposed circuit is then suitable for IC
architecture. The proposed oscillator has high output impedance
which is easy to cascade or dive the external load without the buffer
devices. The PSPICE simulation results are depicted, and the given
results agree well with the theoretical anticipation. The power
consumption is approximately 1.76mW at ±1.25V supply voltages.