Abstract: The conventional assessment of human semen is a
highly subjective assessment, with considerable intra- and interlaboratory
variability. Computer-Assisted Sperm Analysis (CASA)
systems provide a rapid and automated assessment of the sperm
characteristics, together with improved standardization and quality
control. However, the outcome of CASA systems is sensitive to the
method of experimentation. While conventional CASA systems use
digital microscopes with phase-contrast accessories, producing
higher contrast images, we have used raw semen samples (no
staining materials) and a regular light microscope, with a digital
camera directly attached to its eyepiece, to insure cost benefits and
simple assembling of the system. However, since the accurate finding
of sperms in the semen image is the first step in the examination and
analysis of the semen, any error in this step can affect the outcome of
the analysis. This article introduces and explains an algorithm for
finding sperms in low contrast images: First, an image enhancement
algorithm is applied to remove extra particles from the image. Then,
the foreground particles (including sperms and round cells) are
segmented form the background. Finally, based on certain features
and criteria, sperms are separated from other cells.
Abstract: According to previous studies, some muscles present a non-homogeneous spatial distribution of its muscle fiber types and motor unit types. However, available muscle models only deal with muscles with homogeneous distributions. In this paper, a new architecture muscle model is proposed to permit the construction of non-uniform distributions of muscle fibers within the muscle cross section. The idea behind is the use of a motor unit placement algorithm that controls the spatial overlapping of the motor unit territories of each motor unit type. Results show the capabilities of the new algorithm to reproduce arbitrary muscle fiber type distributions.
Abstract: Severe acute respiratory syndrome (SARS) is a respiratory disease in humans which is caused by the SARS coronavirus. The treatment of coronavirus-associated SARS has been evolving and so far there is no consensus on an optimal regimen. The mainstream therapeutic interventions for SARS involve broad-spectrum antibiotics and supportive care, as well as antiviral agents and immunomodulatory therapy. The Protein- Ligand interaction plays a significant role in structural based drug designing. In the present work we have taken the receptor Angiotensin converting enzyme 2 and identified the drugs that are commonly used against SARS. They are Lopinavir, Ritonavir, Ribavirin, and Oseltamivir. The receptor Angiotensin converting enzyme 2 (ACE-2) was docked with above said drugs and the energy value obtained are as follows, Lopinavir (-292.3), Ritonavir (-325.6), Oseltamivir (- 229.1), Ribavirin (-208.8). Depending on the least energy value we have chosen the best two drugs out of the four conventional drugs. We tried to improve the binding efficiency and steric compatibility of the two drugs namely Ritonavir and Lopinavir. Several modifications were made to the probable functional groups (phenylic, ketonic groups in case of Ritonavir and carboxylic groups in case of Lopinavir respectively) which were interacting with the receptor molecule. Analogs were prepared by Marvin Sketch software and were docked using HEX docking software. Lopinavir analog 8 and Ritonavir analog 11 were detected with significant energy values and are probable lead molecule. It infers that some of the modified drugs are better than the original drugs. Further work can be carried out to improve the steric compatibility of the drug based upon the work done above for a more energy efficient binding of the drugs to the receptor.
Abstract: Within dental-guided surgery, there has been a lack
of analytical methods for optimizing the treatment of the
rehabilitation concepts regarding geometrical variation. The purpose
of this study is to find the source of the greatest geometrical variation
contributor and sensitivity contributor with the help of virtual
variation simulation of a dental drill- and implant-guided surgery
process using a methodical approach. It is believed that lower
geometrical variation will lead to better patient security and higher
quality of dental drill- and implant-guided surgeries. It was found
that the origin of the greatest contributor to the most variation, and
hence where the foci should be set, in order to minimize geometrical
variation was in the assembly category (surgery). This was also the
category that was the most sensitive for geometrical variation.
Abstract: A analysis on the conventional the blood pressure estimation method using an oscillometric sphygmomanometer was
performed through a computer simulation using an arterial pressure-volume (APV) model. Traditionally, the maximum amplitude algorithm (MAP) was applied on the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and
characteristic ratio was significantly affected with the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter
(HPL) circuitry. Experimental errors are due to these effects when estimating blood pressure. To find out an algorithm independent from
the influence of waveform shapes and parameters of HPL, the volume
oscillation of the APV model and the phase shift of the oscillation with fast fourier transform (FFT) were testified while increasing the cuff
pressure from 1 mmHg to 200 mmHg (1 mmHg per second). The phase shift between the ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were also obtained from the simulations performed on two different the arterial blood pressure waveforms and one
hyperthermia waveform.
Abstract: The linear SEF (Spectral Edge Frequency) parameter
and spectrum analysis method can not reflect the non-linear of EEG.
This method can not contribute to acquire real time analysis and obtain
a high confidence in the clinic due to low discrimination. To solve the
problems, the development of a new index is carried out using the
bispectrum analyzing the EEG(electroencephalogram) including the
non-linear characteristic. After analyzing the bispectrum of the 2
dimension, the most significant power spectrum density peaks appeared abundantly at the specific area in awakening and anesthesia state. These points are utilized to create the new index since many
peaks appeared at the specific area in the frequency coordinate. The measured range of an index was 0-100. An index is 20-50 at an anesthesia, while the index is 90-60 at the awake. New index could afford to effectively discriminate the awake and anesthesia state.
Abstract: A four element prototype phased array surface probe
has been designed and constructed to improve clinical human
prostate spectroscopic data. The probe consists of two pairs of
adjacent rectangular coils with an optimum overlap to reduce the
mutual inductance. The two pairs are positioned on the anterior and
the posterior pelvic region and two couples of varactors at the input
of each coil undertake the procedures of tuning and matching. The
probe switches off and on automatically during the consecutive
phases of the MR experiment with the use of an analog switch that is
triggered by a microcontroller. Experimental tests that were carried
out resulted in high levels of tuning accuracy. Also, the switching
mechanism functions properly for various applied loads and pulse
sequence characteristics, producing only 10 μs of latency.
Abstract: The aged are faced with increasing risk for falls. The
aged have the easily fragile bones than others. When falls have
occurred, it is important to detect this emergency state because such
events often lead to more serious illness or even death. A
implementation of PDA system, for detection of emergency situation,
was developed using 3-axis accelerometer in this paper as follows.
The signals were acquired from the 3-axis accelerometer, and then
transmitted to the PDA through Bluetooth module. This system can
classify the human activity, and also detect the emergency state like
falls. When the fall occurs, the system generates the alarm on the
PDA. If a subject does not respond to the alarm, the system determines
whether the current situation is an emergency state or not, and then
sends some information to the emergency center in the case of urgent
situation. Three different studies were conducted on 12 experimental
subjects, with results indicating a good accuracy. The first study was
performed to detect the posture change of human daily activity. The
second study was performed to detect the correct direction of fall. The
third study was conducted to check the classification of the daily
physical activity. Each test was lasted at least 1 min. in third study.
The output of acceleration signal was compared and evaluated by
changing a various posture after attaching a 3-axis accelerometer
module on the chest. The newly developed system has some important
features such as portability, convenience and low cost. One of the
main advantages of this system is that it is available at home
healthcare environment. Another important feature lies in low cost to
manufacture device. The implemented system can detect the fall
accurately, so will be widely used in emergency situation.
Abstract: The Zung self-depression scale and Beck Anxiety Inventory were used to study the depression and anxiety levels of Armenian Crohn's disease patients, as well as to reveal the relation between emotional status and placebo effect of these patients. Despite of registered high levels of depression and anxiety, the high placebo rate during investigations was described. The importance of use of psychotherapies for optimal outcomes during treatments of Crohn's disease is obvious.
Abstract: A mathematical model of the respiratory system is
introduced in this study. Geometrical dimensions of the respiratory
system were used to compute the acoustic properties of the
respiratory system using the electro-acoustic analogy. The effect of
the geometrical proportions of the respiratory system is observed in
the paper.
Abstract: As the increase of intraoral acidity due to ingestion of sweet foods and acidic beverages usually bring forth a dental caries and a erosion, the measurement of intraoral pH is essential in the study of oral environment. The indwelling intraoral pH telemetry for lasting longer than 24 hours in the mouth was developed to overcome the limits of conventional wire electrode method previously used for salivary and plaque pH measurement, and to assess its effectiveness.
Abstract: The size, complexity and number of databases used
for protein information have caused bioinformatics to lag behind in
adapting to the need to handle this distributed information.
Integrating all the information from different databases into one
database is a challenging problem. Our main research is to develop a
tool which can be used to access and manipulate protein information
from difference databases. In our approach, we have integrated
difference databases such as Swiss-prot, PDB, Interpro, and EMBL
and transformed these databases in flat file format into relational
form using XML and Bioperl. As a result, we showed this tool can
search different sizes of protein information stored in relational
database and the result can be retrieved faster compared to flat file
database. A web based user interface is provided to allow user to
access or search for protein information in the local database.
Abstract: One of the essential requirements in order to have a
realistic surgical simulator is real-time interaction by means of a
haptic interface is. In fact, reproducing haptic sensations increases
the realism of the simulation. However, the interaction need to be
performed in real-time, since a delay between the user action and the
system reaction reduces the user immersion. In this paper, we present
a prototype of the coronary stent implant simulator developed in the
HERMES Project; this system allows real-time interactions with a
artery by means of a specific haptic device; thus the user can
interactively navigate in a reconstructed artery and force feedback is
produced when contact occurs between the artery walls and the
medical instruments