Abstract: There is little published research about the influence of execution methods on structural behavior. Structural analysis is typically based on a constructed building, considering the actions of all forces under which it was designed. However, during construction, execution loads do not match those designed, and in some cases the loads begin to act when the concrete has not yet reached its maximum strength. Changes to structural element support conditions may occur, resulting in unforeseen alterations to the structure’s behavior. Shoring is an example of a construction process that, if executed improperly, will directly influence the structural performance, and may result in unpredicted cracks and displacements. The NBR 14931/2004 standard, which guides the execution of reinforced concrete structures, mentions that shoring must be executed in a way that avoids unpredicted loads and that it may be removed after previous analysis of the structure’s behavior by the professional responsible for the structure’s design. Differences in structural behavior are reduced for small spans. It is important to qualify and quantify how the incorrect placement of shores can compromise a structure’s safety. The results of this research allowed a more precise acknowledgment of the relationship between spans and loads, for which the influence of execution processes can be considerable, and reinforced that civil engineering practice must be performed with the presence of a qualified professional, respecting existing standards’ guidelines.
Abstract: 5
In order to eradicate the degradation of reinforced concrete structures due to the steel corrosion, professionals in constructions suggest using fiber reinforced polymers (FRP) for their excellent properties. Nevertheless, high temperatures may affect the bond between FRP bar and concrete, and consequently the serviceability of FRP-reinforced concrete structures. This paper presents a nonlinear numerical investigation using ADINA software to investigate the effect of the spacing between glass FRP (GFRP) bars embedded in concrete on circumferential thermal deformations and the distribution of radial thermal cracks in reinforced concrete beams submitted to high temperature variations up to 60 °C for asymmetrical problems. The thermal deformations predicted from nonlinear finite elements model, at the FRP bar/concrete interface and at the external surface of concrete cover, were established as a function of the ratio of concrete cover thickness to FRP bar diameter (c/db) and the ratio of spacing between FRP bars in concrete to FRP bar diameter (e/db). Numerical results show that the circumferential thermal deformations at the external surface of concrete cover are linear until cracking thermal load varied from 32 to 55 °C corresponding to the ratio of e/db varied from 1.3 to 2.3, respectively. However, for ratios e/db >2.3 and c/db >1.6, the thermal deformations at the external surface of concrete cover exhibit linear behavior without any cracks observed on the specified surface. The numerical results are compared to those obtained from analytical models validated by experimental tests.
Abstract: The vast majority of the Middle East countries are prone to earthquakes. Despite that and from a seismic hazard point of view, the higher values of the superimposed dead load intensity of partitions and wearing materials of the constructed reinforced concrete slabs in these countries can increase the earthquake vulnerability of the structures. The primary objective of this paper is to investigate the effect of reducing superimposed dead load on the lateral seismic deformations of structures, the inter-story drifts and the seismic pounding damages. The study utilizes a group of three reinforced concrete structures at three different site conditions. These structures are assumed to be constructed in Nablus city of Palestine, and having superimposed dead load value as 1 kN/m2, 3 kN/m2, and 5 kN/m2, respectively. SAP2000 program, Version 18.1.1, is used to perform the response spectrum analysis to obtain the potential lateral seismic deformations of the studied models. Amazingly, the study points that, at the same site, superimposed dead load has a minor effect on the lateral deflections of the models. This, however, promotes the hypothesis that buildings failed during earthquakes mainly because they were not designed appropriately against gravity loads.
Abstract: This paper focuses on parametric analysis of reinforced concrete structures equipped with supplemental damping braces. Practitioners still luck sufficient data for current design of damper added structures and often reduce the real model to a pure damper braced structure even if this assumption is neither realistic nor conservative. In the present study, the damping brace is modelled as made by a linear supporting brace connected in series with the viscous/hysteretic damper. Deformation capacity of existing structures is usually not adequate to undergo the design earthquake. In spite of this, additional dampers could be introduced strongly limiting structural damage to acceptable values, or in some cases, reducing frame response to elastic behavior. This work is aimed at providing useful considerations for retrofit of existing buildings by means of supplemental damping braces. The study explicitly takes into consideration variability of (a) relative frame to supporting brace stiffness, (b) dampers’ coefficient (viscous coefficient or yielding force) and (c) non-linear frame behavior. Non-linear time history analysis has been run to account for both dampers’ behavior and non-linear plastic hinges modelled by Pivot hysteretic type. Parametric analysis based on previous studies on SDOF or MDOF linear frames provide reference values for nearly optimal damping systems design. With respect to bare frame configuration, seismic response of the damper-added frame is strongly improved, limiting deformations to acceptable values far below ultimate capacity. Results of the analysis also demonstrated the beneficial effect of stiffer supporting braces, thus highlighting inadequacy of simplified pure damper models. At the same time, the effect of variable damping coefficient and yielding force has to be treated as an optimization problem.
Abstract: The construction industry is currently trying to develop sustainable reinforced concrete structures. In trying to aid in the effort, the research presented in this paper aims to prove the efficiency of modified special hybrid moment frames composed of discretely jointed precast and post-tensioned concrete members. This aim is due to the fact that current design standards do not cover the spatial design of moment frame structures assembled by post-tensioning with special hybrid joints. This lack of standardization is coupled with the fact that previous experimental programs, available in scientific literature, deal mainly with plane structures and offer little information regarding spatial behavior. A spatial model of a modified hybrid moment frame is experimentally analyzed. The experimental results of a natural scale model test of a corner column-beams sub-structure, cut from an actual multilevel building tested to seismic type loading are presented in order to highlight the behavior of this type of structure. The test is performed under alternative cycles of imposed lateral displacements, up to a storey drift ratio of 0.035. Seismic response of the spatial model is discussed considering the acceptance criteria for reinforced concrete frame structures designed based on experimental tests, as well as some of its major sustainability features. The results obtained show an overall excellent behavior of the system. The joint detailing allows for quick and cheap repairs after an accidental event and a self-balancing behavior of the system that ensures it can be used almost immediately after an accidental event it.
Abstract: This paper presents an analysis of the “Performance-Based” seismic design method, in order to overcome the perceived disadvantages and limitations of the existing seismic design approach based on force, in engineering practice. Bearing in mind, the specificity of the earthquake as a load and the fact that the seismic resistance of the structures solely depends on its behaviour in the nonlinear field, traditional seismic design approach based on force and linear analysis is not adequate. “Performance-Based” seismic design method is based on nonlinear analysis and can be used in everyday engineering practice. This paper presents the application of this method to eight-story high reinforced concrete building with combined structural system (reinforced concrete frame structural system in one direction and reinforced concrete ductile wall system in other direction). The nonlinear time-history analysis is performed on the spatial model of the structure using program Perform 3D, where the structure is exposed to forty real earthquake records. For considered building, large number of results were obtained. It was concluded that using this method we could, with a high degree of reliability, evaluate structural behavior under earthquake. It is obtained significant differences in the response of structures to various earthquake records. Also analysis showed that frame structural system had not performed well at the effect of earthquake records on soil like sand and gravel, while a ductile wall system had a satisfactory behavior on different types of soils.
Abstract: Reinforced cement concrete is getting extensively used
for construction of different type of structures for the last one century.
During this period, we have constructed many structures like
buildings, bridges, industrial structures, pavement, water tanks etc.
using this construction material. These structures have been created
with huge investment of resources. It is essential to maintain those
structures in functional condition. Since deterioration in RCC
Structures is a common and natural phenomenon it is required to have
a detailed plan, methodology for structural repair and rehabilitation
shall be in place for dealing such issues. It is important to know exact
reason of distress, type of distress and correct method of repair
concrete structures. The different methods of repair are described in
paper according to distress category which can be refereed for repair.
Major finding of the study is that to protect our structure we need to
have maintenance frequency and correct material to be chosen for
repair. Also workmanship during repair needs to be taken utmost care
for quality repair.
Abstract: In this study, the time-dependent behavior of damaged
reinforced concrete shear wall structures strengthened with composite
plates having variable fibers spacing was investigated to analyze their
seismic response. In the analytical formulation, the adherent and the
adhesive layers are all modeled as shear walls, using the mixed Finite
Element Method (FEM). The anisotropic damage model is adopted to
describe the damage extent of the Reinforced Concrete shear walls.
The phenomenon of creep and shrinkage of concrete has been
determined by Eurocode 2. Large earthquakes recorded in Algeria
(El-Asnam and Boumerdes) have been tested to demonstrate the
accuracy of the proposed method. Numerical results are obtained for non-uniform distributions of
carbon fibers in epoxy matrices. The effects of damage extent and the
delay mechanism creep and shrinkage of concrete are highlighted.
Prospects are being studied.
Abstract: Early pre-code reinforced concrete structures present
undetermined resistance to earthquakes. This situation is particularly
unacceptable in the case of essential structures, such as healthcare
structures and pilgrims' houses. Amongst these, an existing old RC
building in Madinah city (KSA) is seismically evaluated with and
without infill wall and their dynamic characteristics are compared
with measured values in the field using ambient vibration
measurements (AVM). After updating the mathematical models for
this building with the experimental results, three dimensional
pushover analysis (Nonlinear static analysis) was carried out using
commercial structural analysis software incorporating inelastic
material properties for concrete, infill and steel. The purpose of this
analysis is to evaluate the expected performance of structural systems
by estimating, strength and deformation demands in design, and
comparing these demands to available capacities at the performance
levels of interest. The results summarized and discussed.
Abstract: The seismic feedback experiences in Algeria have
shown higher percentage of damages for non-code conforming
reinforced concrete (RC) buildings. Furthermore, the vulnerability of
these buildings was further aggravated due to presence of many
factors (e.g. weak the seismic capacity of these buildings, shorts
columns, Pounding effect, etc.).
Consequently Seismic risk assessments were carried out on
populations of buildings to identify the buildings most likely to
undergo losses during an earthquake. The results of such studies are
important in the mitigation of losses under future seismic events as
they allow strengthening intervention and disaster management plans
to be drawn up.
Within this paper, the state of the existing structures is assessed using
"the vulnerability index" method. This method allows the
classification of RC constructions taking into account both, structural
and non structural parameters, considered to be ones of the main
parameters governing the vulnerability of the structure. Based on
seismic feedback from past earthquakes DPM (damage probability
matrices) were developed too.
Abstract: This study examines the inelastic behavior of adjacent planar reinforced concrete (R.C.) frames subjected to strong ground motions. The investigation focuses on the effects of vertical ground motion on the seismic pounding. The examined structures are modeled and analyzed by RUAUMOKO dynamic nonlinear analysis program using reliable hysteretic models for both structural members and contact elements. It is found that the vertical ground motion mildly affects the seismic response of adjacent buildings subjected to structural pounding and, for this reason, it can be ignored from the displacement and interstorey drifts assessment. However, the structural damage is moderately affected by the vertical component of earthquakes.
Abstract: The prediction of long-term deformations of concrete and reinforced concrete structures has been a field of extensive research and several different creep models have been developed so far. Most of the models were developed for constant concrete stresses, thus, in case of varying stresses a specific superposition principle or time-integration, respectively, is necessary. Nowadays, when modeling concrete creep the engineering focus is rather on the application of sophisticated time-integration methods than choosing the more appropriate creep model. For this reason, this paper presents a method to quantify the uncertainties of creep prediction originating from the selection of creep models or from the time-integration methods. By adapting variance based global sensitivity analysis, a methodology is developed to quantify the influence of creep model selection or choice of time-integration method. Applying the developed method, general recommendations how to model creep behavior for varying stresses are given.
Abstract: One of the most common practices for strengthening
the reinforced concrete structures is the application of FRP (Fiber
Reinforce Plastic) sheets to increase the flexural and shear strengths
of the member. The elastic modulus of FRP is considerably higher
than that of concrete. This will result in debonding between the FRP
sheets and concrete surface. With conventional surface preparation of
concrete, the ultimate capacity of the FRP sheets can hardly be
achieved. New methods for preparation of the bonding surface have
shown improvements in reducing the premature debonding of FRP
sheets from concrete surface. The present experimental study focuses
on the application of grooving method to postpone debonding of the
FRP sheets attached to the side faces of concrete beams for shear
strengthening. Comparison has also been made with conventional
surface preparation method. This study clearly shows the efficiency
of grooving method compared to surface preparation method, in
preventing the debonding phenomenon and in increasing the load
carrying capacity of FRP.
Abstract: This work deals with the initial applications and formulation of an anisotropic plastic-damage constitutive model proposed for non-linear analysis of reinforced concrete structures submitted to a loading with change of the sign. The original constitutive model is based on the fundamental hypothesis of energy equivalence between real and continuous medium following the concepts of the Continuum Damage Mechanics. The concrete is assumed as an initial elastic isotropic medium presenting anisotropy, permanent strains and bimodularity (distinct elastic responses whether traction or compression stress states prevail) induced by damage evolution. In order to take into account the bimodularity, two damage tensors governing the rigidity in tension or compression regimes are introduced. Then, some conditions are introduced in the original version of the model in order to simulate the damage unilateral effect. The three-dimensional version of the proposed model is analyzed in order to validate its formulation when compared to micromechanical theory. The one-dimensional version of the model is applied in the analyses of a reinforced concrete beam submitted to a loading with change of the sign. Despite the parametric identification problems, the initial applications show the good performance of the model.
Abstract: This paper investigates experimentally and
analytically the torsion behavior of steel fibered high strength self
compacting concrete beams reinforced by GFRP bars. Steel fibered
high strength self compacting concrete (SFHSSCC) and GFRP bars
became in the recent decades a very important materials in the
structural engineering field. The use of GFRP bars to replace steel
bars has emerged as one of the many techniques put forward to
enhance the corrosion resistance of reinforced concrete structures.
High strength concrete and GFRP bars attract designers and
architects as it allows improving the durability as well as the esthetics
of a construction. One of the trends in SFHSSCC structures is to
provide their ductile behavior and additional goal is to limit
development and propagation of macro-cracks in the body of
SFHSSCC elements. SFHSSCC and GFRP bars are tough, improve
the workability, enhance the corrosion resistance of reinforced
concrete structures, and demonstrate high residual strengths after
appearance of the first crack. Experimental studies were carried out
to select effective fiber contents. Three types of volume fraction from
hooked shape steel fibers are used in this study, the hooked steel
fibers were evaluated in volume fractions ranging between 0.0%,
0.75% and 1.5%. The beams shape is chosen to create the required
forces (i.e. torsion and bending moments simultaneously) on the test
zone. A total of seven beams were tested, classified into three groups.
All beams, have 200cm length, cross section of 10×20cm,
longitudinal bottom reinforcement of 3