Abstract: Masonry dome structures had been widely used for covering large spans in the past. The seismic assessment of these historical structures is very complicated due to the nonlinear behavior of the material, their rigidness, and special stability configuration. The assessment method based on energy balance concept, as well as the standard pushover analysis, is used to evaluate the effectiveness of these methods in the case of masonry dome structures. The Soltanieh dome building is used as an example to which two methods are applied. The performance points are given from superimposing the capacity, and demand curves in Acceleration Displacement Response Spectra (ADRS) and energy coordination are compared with the nonlinear time history analysis as the exact result. The results show a good agreement between the dynamic analysis and the energy balance method, but standard pushover method does not provide an acceptable estimation.
Abstract: Past earthquakes have shown that seismic events may incur large economic losses in buildings. FEMA P-58 provides engineers a practical tool for the performance seismic assessment of buildings. In this study, FEMA P-58 is applied to two typical Italian pre-1970 reinforced concrete frame buildings, characterized by plain rebars as steel reinforcement and masonry infills and partitions. Given that suitable tools for these buildings are missing in FEMA P- 58, specific fragility curves and loss functions are first developed. Next, building performance is evaluated following a time-based assessment approach. Finally, expected annual losses for the selected buildings are derived and compared with past applications to old RC frame buildings representative of the US building stock.
Abstract: A 15-storey RC building, studied in this paper, is
representative of modern building type constructed in Madina City in
Saudi Arabia before 10 years ago. These buildings are almost
consisting of reinforced concrete skeleton i.e. columns, beams and
flat slab as well as shear walls in the stairs and elevator areas
arranged in the way to have a resistance system for lateral loads
(wind – earthquake loads). In this study, the dynamic properties of
the 15-storey RC building were identified using ambient motions
recorded at several, spatially-distributed locations within each
building. Three dimensional pushover analysis (Nonlinear static
analysis) was carried out using SAP2000 software incorporating
inelastic material properties for concrete, infill and steel. The effect
of modeling the building with and without infill walls, on the
performance point as well as capacity and demand spectra due to EQ
design spectrum function in Madina area has been investigated. ATC-
40 capacity and demand spectra are utilized to get the modification
factor (R) for the studied building. The purpose of this analysis is to
evaluate the expected performance of structural systems by
estimating, strength and deformation demands in design, and
comparing these demands to available capacities at the performance
levels of interest. The results are summarized and discussed.
Abstract: An existing RC building in Madinah is seismically
evaluated with and without infill wall. Four model systems have been
considered i.e. model I (no infill), model IIA (strut infill-update from
field test), model IIB (strut infill- ASCE/SEI 41) and model IIC (strut
infill-Soft storey- ASCE/SEI 41). Three dimensional pushover
analyses have been carried out using SAP2000 software
incorporating inelastic material behavior for concrete, steel and infill
walls. Infill wall has been modeled as equivalent strut according to
suggested equation matching field test measurements and to the
ASCE/SEI 41 equation. The effect of building modeling on the
performance point as well as capacity and demand spectra due to EQ
design spectrum function in Madinah area has been investigated. The
response modification factor (R) for the 5 story RC building is
evaluated from capacity and demand spectra (ATC-40) for the
studied models. The results are summarized and discussed.
Abstract: Early pre-code reinforced concrete structures present
undetermined resistance to earthquakes. This situation is particularly
unacceptable in the case of essential structures, such as healthcare
structures and pilgrims' houses. Amongst these, an existing old RC
building in Madinah city (KSA) is seismically evaluated with and
without infill wall and their dynamic characteristics are compared
with measured values in the field using ambient vibration
measurements (AVM). After updating the mathematical models for
this building with the experimental results, three dimensional
pushover analysis (Nonlinear static analysis) was carried out using
commercial structural analysis software incorporating inelastic
material properties for concrete, infill and steel. The purpose of this
analysis is to evaluate the expected performance of structural systems
by estimating, strength and deformation demands in design, and
comparing these demands to available capacities at the performance
levels of interest. The results summarized and discussed.