Abstract: Steel bracings are used to improve the seismic behaviors of the structures. In this study, 8, 12 and 16 story reinforced concrete (RC) buildings with steel bracings are used in three base shear contributions (25%, 50% and 75%) in the columns. With the help of pushover analysis and capacity curves, the overstrength factors, ductility factors and ductility reduction factors are investigated for braced RC buildings. It is observed that when the base shear contribution in the columns increases the ductility reduction factor also increases. The results show that when the time period of the structures increases, the ductility reduction factors of the structures decrease.
Abstract: Optimal load factors (dead, live and seismic) used for the design of buildings may be different, depending of the seismic ground motion characteristics to which they are subjected, which are closely related to the type of soil conditions where the structures are located. The influence of the type of soil on those load factors, is analyzed in the present study. A methodology that is useful for establishing optimal load factors that minimize the cost over the life cycle of the structure is employed; and as a restriction, it is established that the probability of structural failure must be less than or equal to a prescribed value. The life-cycle cost model used here includes different types of costs. The optimization methodology is applied to two groups of reinforced concrete buildings. One set (consisting on 4-, 7-, and 10-story buildings) is located on firm ground (with a dominant period Ts=0.5 s) and the other (consisting on 6-, 12-, and 16-story buildings) on soft soil (Ts=1.5 s) of Mexico City. Each group of buildings is designed using different combinations of load factors. The statistics of the maximums inter-story drifts (associated with the structural capacity) are found by means of incremental dynamic analyses. The buildings located on firm zone are analyzed under the action of 10 strong seismic records, and those on soft zone, under 13 strong ground motions. All the motions correspond to seismic subduction events with magnitudes M=6.9. Then, the structural damage and the expected total costs, corresponding to each group of buildings, are estimated. It is concluded that the optimal load factors combination is different for the design of buildings located on firm ground than that for buildings located on soft soil.
Abstract: The aim of this paper is to investigate the effect of the building fundamental period of reinforced concrete buildings of (6, 9, and 12-storey), with different floor plans: Symmetric, mono-symmetric, and unsymmetric. These structures are erected at different epicentral distances. Using the Boumerdes, Algeria (2003) earthquake data, we focused primarily on the establishment of the deterministic formulation linking the base shear force to two parameters: The first one is the fundamental period that represents the numerical fingerprint of the structure, and the second one is the epicentral distance used to represent the impact of the earthquake on this force. In a second step, with a view to highlight the effect of uncertainty in these parameters on the analyzed response, these parameters are modeled as random variables with a log-normal distribution. The variability of the coefficients of variation of the chosen uncertain parameters, on the statistics on the seismic base shear force, showed that the effect of uncertainty on fundamental period on this force statistics is low compared to the epicentral distance uncertainty influence.
Abstract: The retrofitting of existing buildings to resist the seismic loads is very important to avoid losing lives or financial disasters. The aim at retrofitting processes is increasing total structure strength by increasing stiffness or ductility ratio. In addition, the response modification factors (R) have to satisfy the code requirements for suggested retrofitting types. In this study, two types of jackets are used, i.e. full reinforced concrete jackets and surrounding steel plate jackets. The study is carried out on an existing building in Madinah by performing static pushover analysis before and after retrofitting the columns. The selected model building represents nearly all-typical structure lacks structure built before 30 years ago in Madina City, KSA. The comparison of the results indicates a good enhancement of the structure respect to the applied seismic forces. Also, the response modification factor of the RC building is evaluated for the studied cases before and after retrofitting. The design of all vertical elements (columns) is given. The results show that the design of retrofitted columns satisfied the code's design stress requirements. However, for some retrofitting types, the ductility requirements represented by response modification factor do not satisfy KSA design code (SBC- 301).
Abstract: Overstrength factor is an important parameter of load reduction factor. In this research, the overstrength factor (Ω) of reinforced concrete (RC) buildings and the parameters of Ω in TEC-2016 draft version have been explored. For this aim, 48 RC buildings have been modeled according to the current seismic code TEC-2007 and Turkish Building Code-500-2000 criteria. After modelling step, nonlinear static pushover analyses have been applied to these buildings by using TEC-2007 Section 7. After the nonlinear pushover analyses, capacity curves (lateral load-lateral top displacement curves) have been plotted for 48 RC buildings. Using capacity curves, overstrength factors (Ω) have been derived for each building. The obtained overstrength factor (Ω) values have been compared with TEC-2016 values for related building types, and the results have been interpreted. According to the obtained values from the study, overstrength factor (Ω) given in TEC-2016 draft code is found quite suitable.
Abstract: In this study, an Artificial Neural Network (ANN)
analytical method has been developed for analyzing earthquake
performances of the Reinforced Concrete (RC) buildings. 66 RC
buildings with four to ten storeys were subjected to performance
analysis according to the parameters which are the existing material,
loading and geometrical characteristics of the buildings. The selected
parameters have been thought to be effective on the performance of
RC buildings. In the performance analyses stage of the study, level of
performance possible to be shown by these buildings in case of an
earthquake was determined on the basis of the 4-grade performance
levels specified in Turkish Earthquake Code-2007 (TEC-2007). After
obtaining the 4-grade performance level, selected 23 parameters of
each building have been matched with the performance level. In this
stage, ANN-based fast evaluation algorithm mentioned above made
an economic and rapid evaluation of four to ten storey RC buildings.
According to the study, the prediction accuracy of ANN has been
found about 74%.
Abstract: The objective of this paper is to evaluate the effects of
soil-structure interaction (SSI) on the modal characteristics and on
the dynamic response of current structures. The objective is on the
overall behaviour of a real structure of five storeys reinforced
concrete (R/C) building typically encountered in Algeria. Sensitivity
studies are undertaken in order to study the effects of frequency
content of the input motion, frequency of the soil-structure system,
rigidity and depth of the soil layer on the dynamic response of such
structures. This investigation indicated that the rigidity of the soil
layer is the predominant factor in soil-structure interaction and its
increases would definitely reduce the deformation in the R/C
structure. On the other hand, increasing the period of the underlying
soil will cause an increase in the lateral displacements at story levels
and create irregularity in the distribution of story shears. Possible
resonance between the frequency content of the input motion and soil
could also play an important role in increasing the structural
response.
Abstract: The goal of the paper is to highlight the effect of the
building design and epicentral distance on the storey lateral
displacements, for several reinforced concrete buildings (6, 9 and 12
stories). These structures are subjected to seismic accelerations from
the Boumerdes earthquake (Algeria, May 21st, Mw = 6.8). Using the
response spectrum method (modal spectral approach), the analysis is
performed in both longitudinal and transverse directions. The
building design is expressed through the fundamental period and
epicentral distance is used to represent the earthquake effect variation
on storey lateral displacements and interstory drift for the considered
buildings.
Abstract: Building code-related literature provides
recommendations on normalizing approaches to the calculation of
the dynamic properties of structures. Most building codes make a
distinction among types of structural systems, construction material,
and configuration through a numerical coefficient in the
expression for the fundamental period. The period is then used in
normalized response spectra to compute base shear. The typical
parameter used in simplified code formulas for the fundamental
period is overall building height raised to a power determined from
analytical and experimental results. However, reinforced concrete
buildings which constitute the majority of built space in less
developed countries pose additional challenges to the ones built with
homogeneous material such as steel, or with concrete under stricter
quality control. In the present paper, the particularities of reinforced
concrete buildings are explored and related to current methods of
equivalent static analysis. A comparative study is presented between
the Uniform Building Code, commonly used for buildings within
and outside the USA, and data from the Middle East used to model
151 reinforced concrete buildings of varying number of bays, number
of floors, overall building height, and individual story height. The
fundamental period was calculated using eigenvalue matrix
computation. The results were also used in a separate regression
analysis where the computed period serves as dependent variable,
while five building properties serve as independent variables. The
statistical analysis shed light on important parameters that simplified
code formulas need to account for including individual story height,
overall building height, floor plan, number of bays, and concrete
properties. Such inclusions are important for reinforced concrete
buildings of special conditions due to the level of concrete damage,
aging, or materials quality control during construction.
Overall results of the present analysis show that simplified code
formulas for fundamental period and base shear may be applied but
they require revisions to account for multiple parameters. The
conclusion above is confirmed by the analytical model where
fundamental periods were computed using numerical techniques and
eigenvalue solutions. This recommendation is particularly relevant
to code upgrades in less developed countries where it is customary to
adopt, and mildly adapt international codes.
We also note the necessity of further research using empirical data
from buildings in Lebanon that were subjected to severe damage due
to impulse loading or accelerated aging. However, we excluded this
study from the present paper and left it for future research as it has its
own peculiarities and requires a different type of analysis.
Abstract: The present report describes the characteristics of
damages and behavior of reinforced concrete buildings during the
tsunami action. The discussion is based on the field damage survey in
selected cities located on the coast of the zone affected by the Great
East Japan Earthquake on March 11, 2011. This earthquake is the most
powerful know earthquake that has hit Japan with a magnitude 9.0 and
with epicenter located at 129 km of Sendai city (off the coast). The
earthquake triggered a destructive tsunami with run up height of up to
40 meters that mainly affect cities located on the Pacific Ocean coast of
the Tohoku region (north-east region of Japan). Reinforced concrete
buildings in general resist the tsunami without collapse however the
non-structural elements like panels and ceilings were severely
damaged. The analysis of damages has permitted to understand the
behavior of RC buildings under tsunami attack, and has also permitted
to establish recommendations for their use to take refuge from tsunami
in places where natural topography makes impossible to reach hilltops
or other safer places.
Abstract: The seismic feedback experiences in Algeria have
shown higher percentage of damages for non-code conforming
reinforced concrete (RC) buildings. Furthermore, the vulnerability of
these buildings was further aggravated due to presence of many
factors (e.g. weak the seismic capacity of these buildings, shorts
columns, Pounding effect, etc.).
Consequently Seismic risk assessments were carried out on
populations of buildings to identify the buildings most likely to
undergo losses during an earthquake. The results of such studies are
important in the mitigation of losses under future seismic events as
they allow strengthening intervention and disaster management plans
to be drawn up.
Within this paper, the state of the existing structures is assessed using
"the vulnerability index" method. This method allows the
classification of RC constructions taking into account both, structural
and non structural parameters, considered to be ones of the main
parameters governing the vulnerability of the structure. Based on
seismic feedback from past earthquakes DPM (damage probability
matrices) were developed too.