Abstract: There are currently many people living with limb loss in the USA. The main causes for amputation can range from vascular disease, to trauma, or cancer. This number is expected increase over the next decade. Many patients have a single prosthetic for the first year but end up getting a second one to accommodate their changing physique. Afterwards, the prosthesis gets replaced every three to five years depending on how often it is used. This could cost the patient up to $500,000 throughout their lifetime. Complications do not end there, however. Due to the absence of nerves, it becomes more difficult to traverse terrain with a prosthetic. Moving on an incline or decline becomes difficult, thus curbs and stairs can be a challenge. Certain physical activities, such as cycling, could be even more strenuous. It will need to be relearned to accommodate for the change in weight, center of gravity, and transfer of energy from the leg to the pedal. The purpose of this research project is to develop a new, alternate below-knee cycling prosthetic using Dieter & Schmidt’s design process approach. It will be subjected to fatigue analysis under dynamic loading to observe the limitations as well as the strengths and weaknesses of the prosthetic. Benchmark comparisons will be made between existing prosthetics and the proposed one, examining the benefits and disadvantages. The resulting prosthetic will be 3D printed using acrylonitrile butadiene styrene (ABS) or polycarbonate (PC) plastic.
Abstract: Radiation therapy has undergone many advancements and evloved from 2D to 3D. Recently, with rapid pace of drug discoveries, cutting edge technology, and clinical trials has made innovative advancements in computer technology and treatment planning and upgraded to intensity modulated radiotherapy (IMRT) which delivers in homogenous dose to tumor and normal tissues. The present study was a hospital-based experience comparing two different conformal radiotherapy techniques for brain tumors. This analytical study design has been conducted at Regional Cancer Centre, India from January 2014 to January 2015. Ten patients have been selected after inclusion and exclusion criteria. All the patients were treated on Artiste Siemens Linac Accelerator. The tolerance level for maximum dose was 6.0 Gyfor lenses and 54.0 Gy for brain stem, optic chiasm and optical nerves as per RTOG criteria. Mean and standard deviation values of PTV98%, PTV 95% and PTV 2% in IMRT were 93.16±2.9, 95.01±3.4 and 103.1±1.1 respectively; for 3DCRT were 91.4±4.7, 94.17±2.6 and 102.7±0.39 respectively. PTV max dose (%) in IMRT and 3D-CRT were 104.7±0.96 and 103.9±1.0 respectively. Maximum dose to the tumor can be delivered with IMRT with acceptable toxicity limits. Variables such as expertise, location of tumor, patient condition, and TPS influence the outcome of the treatment.
Abstract: Brain-Computer Interfaces (BCIs) measure brain
signals activity, intentionally and unintentionally induced by users,
and provides a communication channel without depending on the
brain’s normal peripheral nerves and muscles output pathway.
Feature Selection (FS) is a global optimization machine learning
problem that reduces features, removes irrelevant and noisy data
resulting in acceptable recognition accuracy. It is a vital step
affecting pattern recognition system performance. This study presents
a new Binary Particle Swarm Optimization (BPSO) based feature
selection algorithm. Multi-layer Perceptron Neural Network
(MLPNN) classifier with backpropagation training algorithm and
Levenberg-Marquardt training algorithm classify selected features.
Abstract: Quantitative analyses of whisker movements provide a
means to study functional recovery and regeneration of mouse facial
nerve after an injury. However, accurate tracking of the mouse whisker
movement is challenging. Most methods for whisker tracking require
manual intervention, e.g. fixing the head of the mouse during a study.
Here we describe a semi-automated image processing method, which
is applied to high-speed video recordings of free-moving mice to track
the whisker movements. We first track the head movement of a mouse
by delineating the lower head contour frame-by-frame that allows for
detection of the location and orientation of the head. Then, a region of
interest is identified for each frame; the subsequent application of a
mask and the Hough transform detects the selected whiskers on each
side of the head. Our approach is used to examine the functional
recovery of damaged facial nerves in mice over a course of 21 days.
Abstract: Successful regional anesthesia depends upon precise location of the peripheral nerve or nerve plexus. Locating peripheral nerves is preferred to be done using nerve stimulation. In order to generate a nerve impulse by electrical means, a minimum threshold stimulus of current “rheobase” must be applied to the nerve. The technique depends on stimulating muscular twitching at a close distance to the nerve without actually touching it. Success rate of this operation depends on the accuracy of current intensity pulses used for stimulation .In this paper, we will discuss a circuit and algorithm for closed loop control for the current, theoretical analysis and test results is discussed and results is compared to previous techniques.
Abstract: Brain tumor is inherently serious and life-threatening disease. Brain tumor builds the intracranial pressure in the brain, by shifting the brain or pushing against the skull, and also damaging nerves and healthy brain tissues. This intracranial pressure affects and interferes with normal brain functionality, which results in generation of abnormal electrical activities from brain. With recent development in the medical engineering and instruments, EEG instruments are able to record the brain electric activities with high accuracy, which establishes EEG as a primary tool for diagnosing the brain abnormalities. Research scholars and general physicians, often face difficulty in understanding EEG patterns. This paper presents the EEG patterns associated with brain tumor by combing medicine theory and neurologist experience. Paper also explains the pros-cons of the EEG based brain tumor identification.
Abstract: Radiofrequency (RF) lesioning of nerves have been commonly used to alleviate chronic pain, where RF current preventing transmission of pain signals through the nerve by heating the nerve causing the pain. There are some factors that affect the temperature distribution and the nerve lesion size, one of these factors is the inhomogeneities in the tissue medium. Our objective is to calculate the temperature distribution and the nerve lesion size in an inhomogeneous medium surrounding the RF electrode. A two 3-D finite element models are used to compare the temperature distribution in the homogeneous and inhomogeneous medium. Also the effect of temperature-dependent electric conductivity on maximum temperature and lesion size is observed. Results show that the presence of an inhomogeneous medium around the RF electrode has a valuable effect on the temperature distribution and lesion size. The dependency of electric conductivity on tissue temperature increased lesion size.
Abstract: The use of polypropylene mesh devices for Pelvic
Organ Prolapse (POP) spread rapidly during the last decade, yet our
knowledge of the mesh-tissue interaction is far from complete. We
aimed to perform a thorough pathological examination of explanted
POP meshes and describe findings that may explain mechanisms of
complications resulting in product excision. We report a spectrum of
important findings, including nerve ingrowth, mesh deformation,
involvement of detrusor muscle with neural ganglia, and
polypropylene degradation. Analysis of these findings may improve
and guide future treatment strategies.
Abstract: This paper presented a modified efficient inductive
powering link based on ASK modulator and proposed efficient class-
E power amplifier. The design presents the external part which is
located outside the body to transfer power and data to the implanted
devices such as implanted Microsystems to stimulate and monitoring
the nerves and muscles. The system operated with low band
frequency 10MHZ according to industrial- scientific – medical (ISM)
band to avoid the tissue heating. For external part, the modulation
index is 11.1% and the modulation rate 7.2% with data rate 1 Mbit/s
assuming Tbit = 1us. The system has been designed using 0.35-μm
fabricated CMOS technology. The mathematical model is given and
the design is simulated using OrCAD P Spice 16.2 software tool and
for real-time simulation, the electronic workbench MULISIM 11 has
been used.
Abstract: Sensory nerves in the foot play an important part in the diagnosis of various neuropathydisorders, especially in diabetes mellitus.However, a detailed description of the anatomical distribution of the nerves is currently lacking. A computationalmodel of the afferent nerves inthe foot may bea useful tool for the study of diabetic neuropathy. In this study, we present the development of an anatomically-based model of various major sensory nerves of the sole and dorsal sidesof the foot. In addition, we presentan algorithm for generating synthetic somatosensory nerve networks in the big-toe region of a right foot model. The algorithm was based on a modified version of the Monte Carlo algorithm, with the capability of being able to vary the intra-epidermal nerve fiber density in differentregionsof the foot model. Preliminary results from the combinedmodel show the realistic anatomical structure of the major nerves as well as the smaller somatosensory nerves of the foot. The model may now be developed to investigate the functional outcomes of structural neuropathyindiabetic patients.
Abstract: This paper presented a proposed design for
transcutaneous inductive powering links. The design used to transfer
power and data to the implanted devices such as implanted
Microsystems to stimulate and monitoring the nerves and muscles.
The system operated with low band frequency 13.56 MHZ according
to industrial- scientific – medical (ISM) band to avoid the tissue
heating. For external part, the modulation index is 13 % and the
modulation rate 7.3% with data rate 1 Mbit/s assuming Tbit=1us. The
system has been designed using 0.35-μm fabricated CMOS
technology. The mathematical model is given and the design is
simulated using OrCAD P Spice 16.2 software tool and for real-time
simulation the electronic workbench MULISIM 11 has been used.
The novel circular plane (pancake) coils was simulated using
ANSOFT- HFss software.