Abstract: High Performance Liquid Chromatography (HPLC)
method was developed and validated for simultaneous estimation of
6-Gingerol(6G) and 6-Shogaol(6S) in joint pain relief gel containing
ginger extract. The chromatographic separation was achieved by
using C18 column, 150 x 4.6mm i.d., 5μ Luna, mobile phase
containing acetonitrile and water (gradient elution). The flow rate
was 1.0 ml/min and the absorbance was monitored at 282 nm. The
proposed method was validated in terms of the analytical parameters
such as specificity, accuracy, precision, linearity, range, limit of
detection (LOD), limit of quantification (LOQ), and determined
based on the International Conference on Harmonization (ICH)
guidelines. The linearity ranges of 6G and 6S were obtained over 20-
60 and 6-18 μg/ml respectively. Good linearity was observed over the
above-mentioned range with linear regression equation Y= 11016x-
23778 for 6G and Y = 19276x-19604 for 6S (x is concentration of
analytes in μg/ml and Y is peak area). The value of correlation
coefficient was found to be 0.9994 for both markers. The limit of
detection (LOD) and limit of quantification (LOQ) for 6G were
0.8567 and 2.8555 μg/ml and for 6S were 0.3672 and 1.2238 μg/ml
respectively. The recovery range for 6G and 6S were found to be
91.57 to 102.36 % and 84.73 to 92.85 % for all three spiked levels.
The RSD values from repeated extractions for 6G and 6S were 3.43
and 3.09% respectively. The validation of developed method on
precision, accuracy, specificity, linearity, and range were also
performed with well-accepted results.
Abstract: Radiofrequency (RF) lesioning of nerves have been commonly used to alleviate chronic pain, where RF current preventing transmission of pain signals through the nerve by heating the nerve causing the pain. There are some factors that affect the temperature distribution and the nerve lesion size, one of these factors is the inhomogeneities in the tissue medium. Our objective is to calculate the temperature distribution and the nerve lesion size in an inhomogeneous medium surrounding the RF electrode. A two 3-D finite element models are used to compare the temperature distribution in the homogeneous and inhomogeneous medium. Also the effect of temperature-dependent electric conductivity on maximum temperature and lesion size is observed. Results show that the presence of an inhomogeneous medium around the RF electrode has a valuable effect on the temperature distribution and lesion size. The dependency of electric conductivity on tissue temperature increased lesion size.