Performance Study of Neodymium Extraction by Carbon Nanotubes Assisted Emulsion Liquid Membrane Using Response Surface Methodology

The high purity rare earth elements (REEs) have been vastly used in the field of chemical engineering, metallurgy, nuclear energy, optical, magnetic, luminescence and laser materials, superconductors, ceramics, alloys, catalysts, and etc. Neodymium is one of the most abundant rare earths. By development of a neodymium–iron–boron (Nd–Fe–B) permanent magnet, the importance of neodymium has dramatically increased. Solvent extraction processes have many operational limitations such as large inventory of extractants, loss of solvent due to the organic solubility in aqueous solutions, volatilization of diluents, etc. One of the promising methods of liquid membrane processes is emulsion liquid membrane (ELM) which offers an alternative method to the solvent extraction processes. In this work, a study on Nd extraction through multi-walled carbon nanotubes (MWCNTs) assisted ELM using response surface methodology (RSM) has been performed. The ELM composed of diisooctylphosphinic acid (CYANEX 272) as carrier, MWCNTs as nanoparticles, Span-85 (sorbitan triooleate) as surfactant, kerosene as organic diluent and nitric acid as internal phase. The effects of important operating variables namely, surfactant concentration, MWCNTs concentration, and treatment ratio were investigated. Results were optimized using a central composite design (CCD) and a regression model for extraction percentage was developed. The 3D response surfaces of Nd(III) extraction efficiency were achieved and significance of three important variables and their interactions on the Nd extraction efficiency were found out. Results indicated that introducing the MWCNTs to the ELM process led to increasing the Nd extraction due to higher stability of membrane and mass transfer enhancement. MWCNTs concentration of 407 ppm, Span-85 concentration of 2.1 (%v/v) and treatment ratio of 10 were achieved as the optimum conditions. At the optimum condition, the extraction of Nd(III) reached the maximum of 99.03%.

The Extraction and Stripping of Hg (II) from Produced Water via Hollow Fiber Contactor

The separation of Hg (II) from produced water by hollow fiber contactors (HFC) was investigation. This system included of two hollow fiber modules in the series connecting. The first module used for the extraction reaction and the second module for stripping reaction. Aliquat336 extractant was fed from the organic reservoirs into the shell side of the first hollow fiber module and continuous to the shell side of the second module. The organic liquid was continuously feed recirculate and back to the reservoirs. The feed solution was pumped into the lumen (tube side) of the first hollow fiber module. Simultaneously, the stripping solution was pumped in the same way in tube side of the second module. The feed and stripping solution was fed which had a countercurrent flow. Samples were kept in the outlet of feed and stripping solution at 1 hour and characterized concentration of Hg (II) by Inductively Couple Plasma Atomic Emission Spectroscopy (ICP-AES). Feed solution was produced water from natural gulf of Thailand. The extractant was Aliquat336 dissolved in kerosene diluent. Stripping solution used was nitric acid (HNO3) and thiourea (NH2CSNH2). The effect of carrier concentration and type of stripping solution were investigated. Results showed that the best condition were 10 % (v/v) Aliquat336 and 1.0 M NH2CSNH2. At the optimum condition, the extraction and stripping of Hg (II) were 98% and 44.2%, respectively.

Flow Visualization of Angled Supersonic Jets into a Supersonic Cross Flow

This paper describes Nano-particle based Planar Laser Scattering (NPLS) flow visualization of angled supersonic jets into a supersonic cross flow based on the HYpersonic Low TEmperature (HYLTE) nozzle which was widely used in DF chemical laser. In order to investigate the non-reacting flowfield in the HYLTE nozzle, a testing section with windows was designed and manufactured. The impact of secondary fluids orifice separation on mixing was examined. For narrow separation of orifices, the secondary fuel penetration increased obviously compared to diluent injection, which means smaller separation of diluent and fuel orifices would enhance the mixing of fuel and oxidant. Secondary injections with angles of 30, 40 and 50 degrees were studied. It was found that the injectant penetration increased as the injection angle increased, while the interfacial surface area to entrain the freestream fluid is largest when the injection angle is 40 degree.

Optimization of Growth Conditions for Acidic Protease Production from Rhizopus oligosporus through Solid State Fermentation of Sunflower Meal

Rhizopus oligosporus was used in the present study for the production of protease enzyme under SSF. Sunflower meal was used as by-product of oil industry incorporated with organic salts was employed for the production of protease enzyme. The main purpose of the present was to study different parameters of protease productivity, its yields and to optimize basal fermentation conditions. The optimal conditions found for protease production using sunflower meal as a substrate in the present study were inoculum size (1%), substrate (Sunflower meal), substrate concentration (20 g), pH (3), cultivation period (72 h), incubation temperature (35oC), substrate to diluent-s ratio (1:2) and tween 81 (1 mL). The maximum production of protease in the presence of cheaper substrate at low concentration and stability at acidic pH, these characteristics make the strain and its enzymes useful in different industry.

Adding Olive Oil into Diluents for Improving Semen Quality and Storage Ability of Roosters' Semen during Liquid Storage

The aim of this study was to investigate the effects of supplementing the diluent of roosters' semen with different levels of olive oil on motility, viability, morphology and acrosome integrity of chicken spermatozoa after in vitro storage for up to 72 h. Semen was collected from 60 White Layer males (62 wk of age) kept in separated floor pens and randomly divided into six treatment groups (10 males in each group). Experimental groups were as follows: T1 :fresh semen, T2 : semen extended 1:1 with Al – Daraji 2 diluent (AD2D) alone, T3 – T6 :semen samples extended 1:1 with AD2D supplemented with 2 ml, 4 ml, 6 ml or 8 ml of olive oil / 100 ml of diluent, respectively. Semen samples were then stored at 5 °C for 24 h, 48 h or 72 h. There was a clear influence of diluent supplementation with olive oil on the spermatozoa motility profile; olive oil groups (T3, T4, T5 and T6) recorded the highest scores of mass activity and individual motility during all storage periods compared to T1 and T2 groups. In addition, the inclusion of olive oil into semen diluent (T3, T4, T5 and T6) gave significantly higher percentages of viable spermatozoa, normal morphologically spermatozoa and intact acrosomes irrespective of storage period. These results clearly show that supplementation the diluent of roosters' semen with olive oil can improve semen quality when semen samples in vitro stored at 5 °C for up to 72 h.

Experimental Study of the Extraction of Copper(II) from Sulphuric Acid by Means of Sodium Diethyldithiocarbamate (SDDT)

The present work presents the extraction of copper(II) from sulphuric acid solutions with Sodium diethyldithiocarbamate (SDDT), and six different organic diluents: Dichloromethane, Chloroform, Carbon tetrachloride, Toluene, xylene and Cyclohexane, were tested. The pair SDDT/Chloroform showed to be the most selective in removing the copper cations, and hence was considered throughout the experimental study. The effects of operating parameters such as the initial concentration of the extracting agent, the agitation time, the agitation speed and the acid concentration were considered. For an initial concentration of Cu (II) of 63 ppm in a 0.5 M sulphuric acid solution, both with a mass of the extracting agent of 20 mg, an extraction percentage of about 97.8 % and a distribution coefficient of 44.42 were obtained, respectively, confirming the performance of the SDDT-Chloroform pair.