Abstract: Well-designed composite steel and concrete structures
highlight the good material properties and lower the deficiencies of
steel and concrete, in particular they make use of high tensile strength
of steel and high stiffness of concrete. The most common composite
steel and concrete structure is a simply supported beam, which
concrete slab transferring the slab load to a beam is connected to the
steel cross-section. The aim of this paper is to find the most adequate
numerical model of a simply supported composite beam with the
cross-sectional and material parameters based on the results of a
processed parametric study and numerical analysis. The paper also
evaluates the suitability of using compact concrete with the
lightweight aggregates for composite steel and concrete beams. The
most adequate numerical model will be used in the resent future to
compare the results of laboratory tests.
Abstract: The paper a summary of the results of concretes with
partial substitution of natural aggregates with recycled concrete is
solved. Design formulas of the concretes were characterised with 20,
40 and 60% substitution of natural 8-16mm fraction aggregates with
a selected recycled concrete of analogous coarse fractions. With the
product samples an evaluation of coarse fraction aggregates influence
on fresh concrete consistency and concrete strength in time was
carried out. The results of concretes with aggregates substitution will
be compared to reference formula containing only the fractions of
natural aggregates.
Abstract: This study investigates the effect of moisture
conditioning on the Indirect Tensile Strength (ITS) of asphalt
concrete. As a first step, cylindrical samples of 100 mm diameter and
50 mm thick were prepared using a Superpave gyratory compactor.
Next, the samples were conditioned using Moisture Induced
Susceptibility Test (MIST) device at different numbers of moisture
conditioning cycles. In the MIST device, samples are subjected water
pressure through the sample pores cyclically. The MIST conditioned
samples were tested for ITS. Results show that the ITS does not
change significantly with MIST conditioning at the specific pressure
and cycles adopted in this study.
Abstract: Seismic design criteria based on performance of
structures have recently been adopted by practicing engineers in
response to destructive earthquakes. A simple but efficient
structural-analysis tool capable of predicting both the strength and
ductility is needed to analyze reinforced concrete (RC) structures
under such event. A three-dimensional lattice model is developed in
this study to analyze torsions in high-strength RC members.
Optimization techniques for determining optimal variables in each
lattice model are introduced. Pure torsion tests of RC members are
performed to validate the proposed model. Correlation studies
between the numerical and experimental results confirm that the
proposed model is well capable of representing salient features of the
experimental results.
Abstract: In this paper, the behavior of different types of DST columns has been studied under bending load. Briefly, composite columns consist of an internal carbon steel tube and an external stainless steel wall that the between the walls are filled with concrete. Composite columns are expected to combine the advantages of all three materials and have the advantage of high flexural stiffness of CFDST columns. In this research, ABAQUS software is used for finite element analysis then the results of ultimate strength of the composite sections are illustrated.
Abstract: Self-Consolidating Concrete (SCC) is considered as a relatively new technology created as an effective solution to problems associated with low quality consolidation. A SCC mix is defined as successful if it flows freely and cohesively without the intervention of mechanical compaction. The construction industry is showing high tendency to use SCC in many contemporary projects to benefit from the various advantages offered by this technology.
At this point, a main question is raised regarding the effect of enhanced fluidity of SCC on the structural behavior of high strength self-consolidating reinforced concrete.
A three phase research program was conducted at the American University of Beirut (AUB) to address this concern. The first two phases consisted of comparative studies conducted on concrete and mortar mixes prepared with second generation Sulphonated Naphtalene-based superplasticizer (SNF) or third generation Polycarboxylate Ethers-based superplasticizer (PCE). The third phase of the research program investigates and compares the structural performance of high strength reinforced concrete beam specimens prepared with two different generations of superplasticizers that formed the unique variable between the concrete mixes. The beams were designed to test and exhibit flexure, shear, or bond splitting failure.
The outcomes of the experimental work revealed comparable resistance of beam specimens cast using self-compacting concrete and conventional vibrated concrete. The dissimilarities in the experimental values between the SCC and the control VC beams were minimal, leading to a conclusion, that the high consistency of SCC has little effect on the flexural, shear and bond strengths of concrete members.
Abstract: The ice rink floor is the largest heat exchanger in an ice rink. The important part of the floor consists of concrete, and the thermophysical properties of this concrete have strong influence on the energy usage of the ice rink. The thermal conductivity of concrete can be increased by using iron ore as ballast. In this study, the Transient Plane Source (TPS) method showed an increase up to 58.2% of thermal conductivity comparing the improved concrete to standard concrete. Moreover, two alternative ice rink floor designs are suggested to incorporate the improved concrete. A 2D simulation was developed to investigate the temperature distribution in the conventional and the suggested designs. The results show that the suggested designs reduce the temperature difference between the ice surface and the brine by 1-4˚C, when comparing with convectional designs at equal heat flux. This primarily leads to an increased coefficient of performance (COP) in the primary refrigeration cycle and secondly to a decrease in the secondary refrigerant pumping power. The suggested designs have great potential to reduce the energy usage of ice rinks. Depending on the load scenario in the ice rink, the saving potential lies in the range of 3-10% of the refrigeration system energy usage. This calculation is based on steady state conditions and the potential with improved dynamic behavior is expected to increase the potential saving.
Abstract: Construction industry in Greece consumes annually
more than 25 million tons of natural aggregates originating mainly
from quarries. At the same time, more than 2 million tons of
construction and demolition waste are deposited every year, usually
without control, therefore increasing the environmental impact of this
sector. A potential alternative for saving natural resources and
minimize landfilling, could be the recycling and re-use of Concrete
and Demolition Waste (CDW) in concrete production. Moreover, in
order to conform to the European legislation, Greece is obliged to
recycle non-hazardous construction and demolition waste to a
minimum of 70% by 2020. In this paper characterization of recycled
materials - commercially and laboratory produced, coarse and fine,
Recycled Concrete Aggregates (RCA) - has been performed. Namely,
X-Ray Fluorescence and X-ray diffraction (XRD) analysis were used
for chemical and mineralogical analysis respectively. Physical
properties such as particle density, water absorption, sand equivalent
and resistance to fragmentation were also determined. This study,
first time made in Greece, aims at outlining the differences between
RCA and natural aggregates and evaluating their possible influence
in concrete performance. Results indicate that RCA’s chemical
composition is enriched in Si, Al, and alkali oxides compared to
natural aggregates. X-ray diffraction (XRD) analyses results
indicated the presence of calcite, quartz and minor peaks of mica and
feldspars. From all the evaluated physical properties of coarse RCA,
only water absorption and resistance to fragmentation seem to have a
direct influence on the properties of concrete. Low Sand Equivalent
and significantly high water absorption values indicate that fine
fractions of RCA cannot be used for concrete production unless
further processed. Chemical properties of RCA in terms of water
soluble ions are similar to those of natural aggregates. Four different
concrete mixtures were produced and examined, replacing natural
coarse aggregates with RCA by a ratio of 0%, 25%, 50% and 75%
respectively. Results indicate that concrete mixtures containing
recycled concrete aggregates have a minor deterioration of their
properties (3-9% lower compression strength at 28 days) compared to
conventional concrete containing the same cement quantity.
Abstract: The topic of the article focuses on the evaluation of selected technological factors and their influence on resulting elasticity modulus of concrete. A series of various factors enter into the manufacturing process which, more or less, influences the elasticity modulus. This paper presents the results of concrete in which the influence of water coefficient and the size of maximum fraction of the aggregate on the static elasticity modulus were monitored. Part of selected results of the long-term programme was discussed in which a wide scope of various variants of proposals for the composition of concretes was evaluated.
Abstract: Concrete-filled-steel-tube (CFST) columns are becoming increasingly popular owing to the superior behavior contributed by the composite action. However, this composite action cannot be fully developed because of different dilation properties between steel tube and concrete. During initial compression, there will be de-bonding between the constitutive materials. As a result, the strength, initial stiffness and ductility of CFST columns reduce significantly. To resolve this problem, external confinement in the form of spirals is proposed to improve the interface bonding. In this paper, a total of 14CFST columns with high-strength as well as ultra-high-strength concrete in-filled were fabricated and tested under uni-axial compression. From the experimental results, it can be concluded that the proposed spirals can improve the strength, initial stiffness, ductility and the interface bonding condition of CFST columns by restraining the lateral expansion of steel tube and core concrete. Moreover, the failure modes of confined core concrete change due to the strong confinement provided by spirals.
Abstract: This work had three stages. In the first stage was
examined pull-out process for steel fiber was embedded into a
concrete by one end and was pulled out of concrete under the angle to
pulling out force direction. Angle was varied. On the obtained forcedisplacement
diagrams were observed jumps. For such mechanical
behavior explanation, fiber channel in concrete surface microscopical
experimental investigation, using microscope KEYENCE VHX2000,
was performed.
At the second stage were obtained diagrams for load- crack
opening displacement for breaking homogeneously reinforced and
layered fiberconcrete prisms (with dimensions 10x10x40cm)
subjected to 4-point bending. After testing was analyzed main crack.
At the third stage elaborated prediction model for the fiberconcrete
beam, failure under bending, using the following data: a) diagrams
for fibers pulling out at different angles; b) experimental data about
steel-straight fibers locations in the main crack. Experimental and
theoretical (modeling) data were compared.
Abstract: An experimental study was conducted on foamed concrete with synthetic and natural fibres consisting of AR-glas, polypropylene, steel, kenaf and oil palm fibre. The foamed concrete mixtures produced had a target density of 1000kg/m3 and a mix ratio of (1:1.5:0.45). The fibres were used as additives. The inclusion of fibre was maintained at a volumetric fraction of 0.25 and 0.4%. The water absorption, thermal and shrinkage were determined to study the effect of the fibre on the durability properties of foamed concrete. The results showed that AR-glass fibre has the lowest percentage value of drying shrinkage compared to others.
Abstract: Structural lightweight concrete is used primarily to reduce the dead-load weight in concrete members such as floors in high-rise buildings and bridge decks. With given materials, it is generally desired to have the highest possible strength/unit weight ratio with the lowest cost of concrete. The work presented herein is part of an ongoing research project that investigates the properties of concrete mixes containing locally available Scoria lightweight aggregates and mineral admixtures. Properties considered included: workability, unit weight, compressive strength, and splitting tensile strength. Test results indicated that developing structural lightweight concretes (SLWC) using locally available Scoria lightweight aggregates and specific blends of silica fume and fly ash seems to be feasible. The stress-strain diagrams plotted for the structural LWC mixes developed in this investigation were comparable to a typical stress-strain diagram for normal weight concrete with relatively larger strain capacity at failure in case of LWC.
Abstract: Research on the utilization of fly ash will no longer refer the fly ash as a waste material of thermal power plants. Use of fly ash in concrete making, makes the concrete economical as well as durable. The fly ash is being added to the concrete in three ways namely, as partial replacement to cement, as partial replacement to fine aggregates and as admixture. Addition of fly ash to the concrete in any one of the form mentioned above, makes the concrete more workable and durable than the conventional concrete. Studies on fly ash as partial replacement to cement gained momentum as such replacement makes the concrete economical. In the present study, an attempt has been made to understand the effects of fly ash on the workability characteristics and strength aspects of fly ash concretes. In India major number of thermal power plants is producing low calcium fly ash. Hence in the present investigation low calcium fly ash has been used. Fly ash in concrete was considered for the partial replacement of cement. The percentage replacement of cement by fly ash varied from 0% to 40% at regular intervals of 10%. More over the fine aggregate to coarse aggregate ratio also has been varied as 1:1, 1:2 and 1:3. The workability tests revealed that up to 30% replacement of cement by fly ash in concrete mixes water demand for reduces, beyond 30% replacement of cement by fly ash demanded more water content for constant workability.
Abstract: This paper introduces selected composition of conventional concretes and their resulting mechanical properties at different ages of concrete. With respect to utilization of mineral admixtures, fly ash and ground limestone agents were included in addition to pure Portland binder. The proposal of concrete composition remained constant in basic concrete components such as cement and representation of individual contents of aggregate fractions; weight dosing of admixtures and water dose were only modified. Water dose was chosen in order to achieve identical consistence by settlement for all proposals of concrete composition. Mechanical properties monitored include compression strength, static and dynamic modulus of concrete elasticity, at ages of 7, 28, 90, and 180 days.
Abstract: Silica fume, also known as microsilica (MS) or
condensed silica fume is a by-product of the production of silicon
metal or ferrosilicon alloys. Silica fume is one of the most effective
pozzolanic additives which could be used for ultrahigh performance
and other types of concrete. Despite the fact, however is not entirely
clear, which amount of silica fume is most optimal for UHPC. Main
objective of this experiment was to find optimal amount of silica
fume for UHPC with and without thermal treatment, when different
amount of quartz powder is substituted by silica fume. In this work
were investigated four different composition of UHPC with different
amount of silica fume. Silica fume were added 0, 10, 15 and 20% of
cement (by weight) to UHPC mixture. Optimal amount of silica fume
was determined by slump, viscosity, qualitative and quantitative
XRD analysis and compression strength tests methods.
Abstract: Compatibility between sulfonated acetone- formalehyde superplasticizer (SAF) and copolymer-based grinding aids (GA) were studied by fluidity, Zeta potential, setting time of cement pasts, initial slump and slump flow of concrete and compressive strength of concrete. ESEM, MIP, and XRD were used to investigate the changing of microstructure of interior concrete. The results indicated that GA could noticeably enhance the dispersion ability of SAF. It was found that better fluidity and slump-keeping ability of cement paste were obtained in the case of GA. In addition, GA together with SAF had a certain retardation effect on hydration of cement paste. With increasing of the GA dosage, the dispersion ability and retardation effect of admixture increased. The compressive strength of the sample made with SAF and GA after 28 days was higher than that of the control sample made only with SAF. The initial slump and slump flow of concrete increased by 10.0% and 22.9%, respectively, while 0.09 wt.% GA was used. XRD examination indicated that new products were not found in the case of GA. In addition, more dense arrangement of hydrates and lower porosity of the specimen were observed by ESEM and MIP, which contributed to higher compressive strength.
Abstract: An experimental study was conducted to investigate the effect of hooked-end steel fibers on the flexural behavior of normal and high strength concrete matrices. The fibers content appropriate for the concrete matrices investigated was also determined based on flexural tests on standard prisms. Parameters investigated include: matrix compressive strength ranging from 45 MPa to 70 MPa, corresponding to normal and high strength concrete matrices respectively; fibers volume fraction including 0, 0.5%, 0.76% and 1%, equivalent to 0, 40, 60, and 80 kg/m3 of hooked-end steel fibers respectively. Test results indicated that flexural strength and toughness of normal and high strength concrete matrices were significantly improved with the increase in the fibers content added; whereas a slight improvement in compressive strength was observed for the same matrices. Furthermore, the test results indicated that the effect of increasing the fibers content was more pronounced on increasing the flexural strength of high strength concrete than that of normal concrete.
Abstract: The design specifications for calculating development and lapped splice lengths of reinforcement in concrete are derived from a conventional empirical modelling approach that correlates experimental test data using a single mathematical equation. This paper describes part of a recently completed experimental research program to assess the effects of different structural parameters on the development length requirements of modern high strength steel reinforcing bars, including the case of lapped splices in large-scale reinforced concrete members. The normalized average bond stresses for the different variations of anchorage lengths are assessed according to the general form of a typical empirical analytical model of bond and anchorage. Improved analytical modelling equations are developed in the paper that better correlate the normalized bond strength parameters with the structural parameters of an empirical model of bond and anchorage.
Abstract: Paper focuses on experimental testing of possibilities of mechanical activation of fly ash and observation of influence of specific surface and granulometry on final properties of fresh and hardened concrete. Mechanical grinding prepared various fineness of fly ash, which was classed by specific surface in accordance with Blain and their granulometry was determined by means of laser granulometer. Then, sets of testing specimens were made from mix designs of identical composition with 25% or Portland cement CEM I 42.5 R replaced with fly ash with various specific surface and granulometry. Mix design with only Portland cement was used as reference. Mix designs were tested on consistency of fresh concrete and compressive strength after 7, 28, 60 and 90 days.