Abstract: This paper deals with the harmonic decontamination of current in an electrical grid by an active shunt filter in order to improve power quality. The contribution of this paper is mainly based on the proposal of a control strategy for an active filter based on Duty Cycle Modulation (DCM). First, three-monophase method is applied for the identification of disturbing currents. A Simulink model of this method is given for one phase of the grid. Secondly, two orders were designed: the first one is the Hysteresis Control and the second one is the DCM Control. Finally, a comparative study of the two controls was performed. The results obtained show a significant improvement in the rate of harmonic distortion for both controls. The harmonic distortion for the Hysteresis control is limited by the non-controllability of the switching frequencies of the inverter's switches and reduces the harmonic distortion rate (THD) to 3.12% as opposed to the DCM control which limits the THD to 2.82% which makes it better.
Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.
Abstract: One of the major power quality concerns in modern times is the problem of current harmonics. The current harmonics is caused due to the increase in non-linear loads which is largely dominated by power electronics devices. The Shunt active filtering is one of the best solutions for mitigating current harmonics. This paper describes a fuzzy logic controller based (FLC) based three Phase Shunt active Filter to achieve low current harmonic distortion (THD) and Reactive power compensation. The performance of fuzzy logic controller is analysed under both balanced sinusoidal and unbalanced sinusoidal source condition. The above controller serves the purpose of maintaining DC Capacitor Voltage constant. The proposed shunt active filter uses hysteresis current controller for current control of IGBT based PWM inverter. The simulation results of model in Simulink MATLAB reveals satisfying results.
Abstract: The aim of this paper is to identify an optimum
control strategy of three-phase shunt active filters to minimize the total harmonic distortion factor of the supply current. A classical PIPI cascade control solution of the output current of the active filterand the voltage across the DC capacitor based on Modulus–Optimum
criterion is taken into consideration. The control system operation
has been simulated using Matlab-Simulink environment and the results agree with the theoretical expectation. It is shown that there is
an optimum value of the DC-bus voltage which minimizes the supply current harmonic distortion factor. It corresponds to the equality of the apparent power at the output of the active filter and the apparent power across the capacitor. Finally, predicted results are verified experimentally on a MaxSine active power filter.
Abstract: Nonlinear and unbalance loads in three phase
networks create harmonics and losses. Active and passive filters are
used for elimination or reduction of these effects. Passive filters have
some limitations. For example, they are designed only for a specific
frequency and they may cause to resonance in the network at the
point of common coupling. The other drawback of a passive filter is
that the sizes of required elements are normally large. The active
filter can improve some of limitations of passive filter for example;
they can eliminate more than one harmonic and don't cause resonance
in the network. In this paper inverter analysis have been done
simultaneously in three phase and the RL impedance of the line have
been considered. A sliding mode control based on energy feedback of
capacitors is employed in the design with this method, the dynamic
speed of the filter is improved effectively and harmonics and load
unbalance is compensating quickly.
Abstract: The perfect operation of common Active Filters is depended on accuracy of identification system distortion. Also, using a suitable method in current injection and reactive power compensation, leads to increased filter performance. Due to this fact, this paper presents a method based on predictive current control theory in shunt active filter applications. The harmonics of the load current is identified by using o–d–q reference frame on load current and eliminating the DC part of d–q components. Then, the rest of these components deliver to predictive current controller as a Threephase reference current by using Park inverse transformation. System is modeled in discreet time domain. The proposed method has been tested using MATLAB model for a nonlinear load (with Total Harmonic Distortion=20%). The simulation results indicate that the proposed filter leads to flowing a sinusoidal current (THD=0.15%) through the source. In addition, the results show that the filter tracks the reference current accurately.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: This paper presents a fuzzy logic controlled shunt
active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a
simple method for the calculation of the reference compensation current based of Fast Fourier Transform. This presented filter is able
to operate in both balanced and unbalanced load conditions. A fuzzy
logic based current controller strategy is used to regulate the filter current and hence ensure harmonic free supply current. The validity
of the presented approach in harmonic mitigation is verified via
simulation results of the proposed test system under different loading
conditions.
Abstract: Pulse width modulation (PWM) techniques have been
the subject of intensive research for different industrial and power
sector applications. A large variety of methods, different in concept
and performance, have been newly developed and described. This
paper analyzes the comparative merits of Sinusoidal Pulse Width
Modulation (SPWM) and Space Vector Pulse Width Modulation
(SVPWM) techniques and the suitability of these techniques in a
Shunt Active Filter (SAF). The objective is to select the scheme that
offers effective utilization of DC bus voltage and also harmonic
reduction at the input side. The effectiveness of the PWM techniques
is tested in the SAF configuration with a non linear load. The
performance of the SAF with the SPWM and (SVPWM) techniques
are compared with respect to the THD in source current. The study
reveals that in the context of closed loop SAF control with the
SVPWM technique there is only a minor improvement in THD. The
utilization of the DC bus with SVPWM is also not significant
compared to that with SPWM because of the non sinusoidal
modulating signal from the controller in SAF configuration.
Abstract: In recent years the large scale use of the power electronic equipment has led to an increase of harmonics in the power system. The harmonics results into a poor power quality and have great adverse economical impact on the utilities and customers. Current harmonics are one of the most common power quality problems and are usually resolved by using shunt active filter (SHAF). The main objective of this work is to develop PI and Fuzzy logic controllers (FLC) to analyze the performance of Shunt Active Filter for mitigating current harmonics under balanced and unbalanced sinusoidal source voltage conditions for normal load and increased load. When the supply voltages are ideal (balanced), both PI and FLC are converging to the same compensation characteristics. However, the supply voltages are non-ideal (unbalanced), FLC offers outstanding results. Simulation results validate the superiority of FLC with triangular membership function over the PI controller.