Abstract: In recent years, maintenance optimization has attracted special attention due to the growth of industrial systems complexity. Maintenance costs are high for many systems, and preventive maintenance is effective when it increases operations' reliability and safety at a reduced cost. The novelty of this research is to consider general repair in the modeling of multi-unit series systems and solve the maintenance problem for such systems using the semi-Markov decision process (SMDP) framework. We propose an opportunistic maintenance policy for a series system composed of two main units. Unit 1, which is more expensive than unit 2, is subjected to condition monitoring, and its deterioration is modeled using a gamma process. Unit 1 hazard rate is estimated by the proportional hazards model (PHM), and two hazard rate control limits are considered as the thresholds of maintenance interventions for unit 1. Maintenance is performed on unit 2, considering an age control limit. The objective is to find the optimal control limits and minimize the long-run expected average cost per unit time. The proposed algorithm is applied to a numerical example to compare the effectiveness of the proposed policy (policy Ⅰ) with policy Ⅱ, which is similar to policy Ⅰ, but instead of general repair, replacement is performed. Results show that policy Ⅰ leads to lower average cost compared with policy Ⅱ.
Abstract: Shaped Metal Deposition (SMD) in additive layered manufacturing technique is a promising alternative to traditional manufacturing used for manufacturing large, expensive metal components with complex geometry in addition to producing free structures by building materials in a layer by layer technique. The present paper is a comprehensive review of the literature and the latest rapid manufacturing technologies of the SMD technique. The aim of this paper is to comprehensively review the most prominent facts that researchers have dealt with in the SMD techniques especially those associated with the cold wire feed. The intent of this study is to review the literature presented on metal deposition processes and their classifications, including SMD process using Wire + Arc Additive Manufacturing (WAAM) which divides into wire + tungsten inert gas (TIG), metal inert gas (MIG), or plasma. This literary research presented covers extensive details on bead geometry, process parameters and heat input or arc energy resulting from the deposition process in both cases MIG and Tandem-MIG in SMD process. Furthermore, SMD may be done using Single Wire-MIG (SW-MIG) welding and SMD using Double Wire-MIG (DW-MIG) welding. The present review shows that the method of deposition of metals when using the DW-MIG process can be considered a distinctive and low-cost method to produce large metal components due to high deposition rates as well as reduce the input of high temperature generated during deposition and reduce the distortions. However, the accuracy and surface finish of the MIG-SMD are less as compared to electron and laser beam.
Abstract: In this paper, we propose a condition-based
maintenance policy for multi-unit systems considering the
existence of economic dependency among units. We consider a
system composed of N identical units, where each unit deteriorates
independently. Deterioration process of each unit is modeled as a
three-state continuous time homogeneous Markov chain with two
working states and a failure state. The average production rate of
units varies in different working states and demand rate of the
system is constant. Units are inspected at equidistant time epochs,
and decision regarding performing maintenance is determined by the
number of units in the failure state. If the total number of units in the
failure state exceeds a critical level, maintenance is initiated, where
units in failed state are replaced correctively and deteriorated state
units are maintained preventively. Our objective is to determine the
optimal number of failed units to initiate maintenance minimizing
the long run expected average cost per unit time. The problem is
formulated and solved in the semi-Markov decision process (SMDP)
framework. A numerical example is developed to demonstrate the
proposed policy and the comparison with the corrective maintenance
policy is presented.
Abstract: This paper presents a maintenance policy for a system
consisting of two units. Unit 1 is gradually deteriorating and is
subject to soft failure. Unit 2 has a general lifetime distribution
and is subject to hard failure. Condition of unit 1 of the system
is monitored periodically and it is considered as failed when its
deterioration level reaches or exceeds a critical level N. At the
failure time of unit 2 system is considered as failed, and unit 2
will be correctively replaced by the next inspection epoch. Unit 1
or 2 are preventively replaced when deterioration level of unit 1
or age of unit 2 exceeds the related preventive maintenance (PM)
levels. At the time of corrective or preventive replacement of unit
2, there is an opportunity to replace unit 1 if its deterioration
level reaches the opportunistic maintenance (OM) level. If unit
2 fails in an inspection interval, system stops operating although
unit 1 has not failed. A mathematical model is derived to find
the preventive and opportunistic replacement levels for unit 1 and
preventive replacement age for unit 2, that minimize the long run
expected average cost per unit time. The problem is formulated and
solved in the semi-Markov decision process (SMDP) framework.
Numerical example is provided to illustrate the performance of the
proposed model and the comparison of the proposed model with an
optimal policy without opportunistic maintenance level for unit 1 is
carried out.
Abstract: The wide range of industrial applications involved with boiling flows promotes the necessity of establishing fundamental knowledge in boiling flow phenomena. For this purpose, a number of experimental and numerical researches have been performed to elucidate the underlying physics of this flow. In this paper, the improved wall boiling models, implemented on ANSYS CFX 14.5, were introduced to study subcooled boiling flow at elevated pressure. At the heated wall boundary, the Fractal model, Force balance approach and Mechanistic frequency model are given for predicting the nucleation site density, bubble departure diameter, and bubble departure frequency. The presented wall heat flux partitioning closures were modified to consider the influence of bubble sliding along the wall before the lift-off, which usually happens in the flow boiling. The simulation was performed based on the Two-fluid model, where the standard k-ω SST model was selected for turbulence modelling. Existing experimental data at around 5 bars were chosen to evaluate the accuracy of the presented mechanistic approach. The void fraction and Interfacial Area Concentration (IAC) are in good agreement with the experimental data. However, the predicted bubble velocity and Sauter Mean Diameter (SMD) are over-predicted. This over-prediction may be caused by consideration of only dispersed and spherical bubbles in the simulations. In the future work, the important physical mechanisms of bubbles, such as merging and shrinking during sliding on the heated wall will be incorporated into this mechanistic model to enhance its capability for a wider range of flow prediction.
Abstract: Automated Optical Inspection (AOI) Systems are commonly used on Printed Circuit Boards (PCB) manufacturing. The use of this technology has been proven as highly efficient for process improvements and quality achievements. The correct extraction of the component for posterior analysis is a critical step of the AOI process. Nowadays, the Pattern Matching Algorithm is commonly used, although this algorithm requires extensive calculations and is time consuming. This paper will present an improved algorithm for the component localization process, with the capability of implementation in a parallel execution system.
Abstract: The goal of this work is to develop sustainable and durable ceramic cellular structures using widely available natural resources- clay and milled waste glass. Present paper describes method of obtaining clay ceramic foam (CCF) with addition of milled waste glass in 5, 7 and 10 wt% by direct foaming with high speed mixer-disperser (HSMD). For more efficient clay and waste glass milling and mixing, the high velocity disintegrator was used. The CCF with 5, 7, and 10 wt% were obtained at 900, 950, 1000 and 1050 °C firing temperature and they have demonstrated mechanical compressive strength for all 12 samples ranging from 3.8 to 14.3 MPa and porosity 76-65%. Obtained CCF has compressive strength 14.3 MPa and porosity 65.3%.
Abstract: Present paper describes method of obtaining clay
ceramic foam (CCF) and foam concrete (FC), by direct foaming with
high speed mixer-disperser (HSMD). Three foaming agents (FA) are
compared for the FC and CCF production: SCHÄUMUNGSMITTEL
W 53 FLÜSSIG (Zschimmer & Schwarz Gmbh, Germany), SCF-
1245 (Sika, test sample, Latvia) and FAB-12 (Elade, Latvija). CCF
were obtained at 950, 1000°C, 1150°C and 1150°C firing temperature
and have mechanical compressive strength 1.2, 2.55 and 4.3 MPa and
porosity 79.4, 75.1, 71.6%, respectively. Obtained FC has 6-14 MPa
compressive strength and porosity 44-55%. The goal of this work
was development of a sustainable and durable ceramic cellular
structures using HSMD.
Abstract: An effort for the detection of damages in the
reinforcement bars of reinforced concrete members using PZTs is
presented. The damage can be the result of excessive elongation of
the steel bar due to steel yielding or due to local steel corrosion. In
both cases the damage is simulated by considering reduced diameter
of the rebar along the damaged part of its length. An integration
approach based on both electromechanical admittance methodology
and guided wave propagation technique is used to evaluate the
artificial damage on the examined longitudinal steel bar. Two
actuator PZTs and a sensor PZT are considered to be bonded on the
examined steel bar. The admittance of the Sensor PZT is calculated
using COMSOL 3.4a. Fast Furrier Transformation for a better
evaluation of the results is employed. An effort for the quantification
of the damage detection using the root mean square deviation
(RMSD) between the healthy condition and damage state of the
sensor PZT is attempted. The numerical value of the RSMD yields a
level for the difference between the healthy and the damaged
admittance computation indicating this way the presence of damage
in the structure. Experimental measurements are also presented.