Abstract: Having considered tactile sensing and palpation of a
surgeon in order to detect kidney stone during open surgery; we
present the 2D model of nephrolithiasis (two dimensional model of
kidney containing a simulated stone). The effects of stone existence
that appear on the surface of kidney (because of exerting mechanical
load) are determined. Using Finite element method, it is illustrated
that the created stress patterns on the surface of kidney and stress
graphs not only show existence of stone inside kidney, but also show
its exact location.
Abstract: This paper presents how the real-time chatter
prevention can be realized by feedback of acoustic cutting signal, and
the efficacy of the proposed adaptive spindle speed tuning algorithm is
verified by intensive experimental simulations. A pair of
microphones, perpendicular to each other, is used to acquire the
acoustic cutting signal resulting from milling chatter. A real-time
feedback control loop is constructed for spindle speed compensation
so that the milling process can be ensured to be within the stability
zone of stability lobe diagram. Acoustic Chatter Signal Index (ACSI)
and Spindle Speed Compensation Strategy (SSCS) are proposed to
quantify the acoustic signal and actively tune the spindle speed
respectively. By converting the acoustic feedback signal into ACSI,
an appropriate Spindle Speed Compensation Rate (SSCR) can be
determined by SSCS based on real-time chatter level or ACSI.
Accordingly, the compensation command, referred to as Added-On
Voltage (AOV), is applied to increase/decrease the spindle motor
speed. By inspection on the precision and quality of the workpiece
surface after milling, the efficacy of the real-time chatter prevention
strategy via acoustic signal feedback is further assured.
Abstract: The iris recognition technology is the most accurate,
fast and less invasive one compared to other biometric techniques
using for example fingerprints, face, retina, hand geometry, voice or
signature patterns. The system developed in this study has the
potential to play a key role in areas of high-risk security and can
enable organizations with means allowing only to the authorized
personnel a fast and secure way to gain access to such areas. The
paper aim is to perform the iris region detection and iris inner and
outer boundaries localization. The system was implemented on
windows platform using Visual C# programming language. It is easy
and efficient tool for image processing to get great performance
accuracy. In particular, the system includes two main parts. The first
is to preprocess the iris images by using Canny edge detection
methods, segments the iris region from the rest of the image and
determine the location of the iris boundaries by applying Hough
transform. The proposed system tested on 756 iris images from 60
eyes of CASIA iris database images.
Abstract: It is established that the instantaneous heart rate (HR) of healthy humans keeps on changing. Analysis of heart rate variability (HRV) has become a popular non invasive tool for assessing the activities of autonomic nervous system. Depressed HRV has been found in several disorders, like diabetes mellitus (DM) and coronary artery disease, characterised by autonomic nervous dysfunction. A new technique, which searches for pattern repeatability in a time series, is proposed specifically for the analysis of heart rate data. These set of indices, which are termed as pattern repeatability measure and pattern repeatability ratio are compared with approximate entropy and sample entropy. In our analysis, based on the method developed, it is observed that heart rate variability is significantly different for DM patients, particularly for patients with diabetic foot ulcer.
Abstract: Nosocomial (i.e., hospital-acquired) infections
(NI) is a major cause of morbidity and mortality in hospitals. NI
rate is higher in intensive care units (ICU) than in the general
ward due to patients with severe symptoms, poor immunity,
and accepted many invasive therapies. Contact behaviors
between health caregivers and patients is one of the infect
factors. It is difficult to obtain complete contact records by
traditional method of retrospective analysis of medical records.
This paper establishes a contact history inferential model
(CHIM) intended to extend the use of Proximity Sensing of
rapid frequency identification (RFID) technology to
transferring all proximity events between health caregivers and
patients into clinical events (close-in events, contact events and
invasive events).The results of the study indicated that the
CHIM can infer proximity care activities into close-in events
and contact events.
The infection control team could redesign and build optimal
workflow in the ICU according to the patient-specific contact
history which provided by our automatic tracing system.
Abstract: In this paper authors presented the research of textile electroconductive materials, which can be used to construction
sensory textronic shirt to breath frequency measurement.
The full paper also will present results of measurements carried
out on unique measurement stands.
Abstract: Endovascular aneurysm repair is a new and minimally invasive repair for patients with abdominal aortic aneurysm (AAA). This method has potential advantages that are incomparable with other repair methods. However, the enlargement of aneurysm in the absence of endoleak, which is known as endotension, may occur as one of post-operative compliances of this method. Typically, endotension is mainly as a result of pressure transmitted to aneurysm sac by endovascular installed graft. After installation of graft the aneurysm sac reduces significantly but remains non-zero. There are some factors which affect this pressure transmitted. In this study, the geometry features of installed vascular graft have been considered. It is inferred that graft neck angle and iliac bifurcation angle are two factors which can affect the drag force on graft and consequently the pressure transmitted to aneurysm.
Abstract: Functional imaging procedures for the non-invasive assessment of tissue microcirculation are highly requested, but require a mathematical approach describing the trans- and intercapillary passage of tracer particles. Up to now, two theoretical, for the moment different concepts have been established for tracer kinetic modeling of contrast agent transport in tissues: pharmacokinetic compartment models, which are usually written as coupled differential equations, and the indicator dilution theory, which can be generalized in accordance with the theory of lineartime- invariant (LTI) systems by using a convolution approach. Based on mathematical considerations, it can be shown that also in the case of an open two-compartment model well-known from functional imaging, the concentration-time course in tissue is given by a convolution, which allows a separation of the arterial input function from a system function being the impulse response function, summarizing the available information on tissue microcirculation. Due to this reason, it is possible to integrate the open two-compartment model into the system-theoretic concept of indicator dilution theory (IDT) and thus results known from IDT remain valid for the compartment approach. According to the long number of applications of compartmental analysis, even for a more general context similar solutions of the so-called forward problem can already be found in the extensively available appropriate literature of the seventies and early eighties. Nevertheless, to this day, within the field of biomedical imaging – not from the mathematical point of view – there seems to be a trench between both approaches, which the author would like to get over by exemplary analysis of the well-known model.
Abstract: Image segmentation is an important step in image
processing. Major developments in medical imaging allow
physicians to use potent and non-invasive methods in order to
evaluate structures, performance and to diagnose human diseases. In
this study, an active contour was used to extract vessel networks
from color retina images. Automatic analysis of retina vessels
facilitates calculation of arterial index which is required to diagnose
some certain retinopathies.
Abstract: Chronic hepatitis B can evolve to cirrhosis and liver
cancer. Interferon is the only effective treatment, for carefully selected
patients, but it is very expensive. Some of the selection criteria are
based on liver biopsy, an invasive, costly and painful medical procedure.
Therefore, developing efficient non-invasive selection systems,
could be in the patients benefit and also save money. We investigated
the possibility to create intelligent systems to assist the Interferon
therapeutical decision, mainly by predicting with acceptable accuracy
the results of the biopsy. We used a knowledge discovery in integrated
medical data - imaging, clinical, and laboratory data. The resulted
intelligent systems, tested on 500 patients with chronic hepatitis
B, based on C5.0 decision trees and boosting, predict with 100%
accuracy the results of the liver biopsy. Also, by integrating the other
patients selection criteria, they offer a non-invasive support for the
correct Interferon therapeutic decision. To our best knowledge, these
decision systems outperformed all similar systems published in the
literature, and offer a realistic opportunity to replace liver biopsy in
this medical context.
Abstract: Artifact free photoplethysmographic (PPG) signals are
necessary for non-invasive estimation of oxygen saturation (SpO2) in
arterial blood. Movement of a patient corrupts the PPGs with motion
artifacts, resulting in large errors in the computation of Sp02. This
paper presents a study on using Kalman Filter in an innovative way
by modeling both the Artillery Blood Pressure (ABP) and the
unwanted signal, additive motion artifact, to reduce motion artifacts
from corrupted PPG signals. Simulation results show acceptable
performance regarding LMS and variable step LMS, thus
establishing the efficacy of the proposed method.
Abstract: Microcirculation is essential for the proper supply of
oxygen and nutritive substances to the biological tissue and the
removal of waste products of metabolism. The determination of
blood flow in the capillaries is therefore of great interest to clinicians.
A comparison has been carried out using the developed non-invasive,
non-contact and whole field laser speckle contrast imaging (LSCI)
based technique and as well as a commercially available laser
Doppler blood flowmeter (LDF) to evaluate blood flow at the finger
tip and elbow and is presented here. The LSCI technique gives more
quantitative information on the velocity of blood when compared to
the perfusion values obtained using the LDF. Measurement of blood
flow in capillaries can be of great interest to clinicians in the
diagnosis of vascular diseases of the upper extremities.
Abstract: Wireless capsule Endoscopy (WCE) has rapidly
shown its wide applications in medical domain last ten years
thanks to its noninvasiveness for patients and support for thorough
inspection through a patient-s entire digestive system including
small intestine. However, one of the main barriers to efficient
clinical inspection procedure is that it requires large amount of
effort for clinicians to inspect huge data collected during the
examination, i.e., over 55,000 frames in video. In this paper, we
propose a method to compute meaningful motion changes of
WCE by analyzing the obtained video frames based on regional
optical flow estimations. The computed motion vectors are used to
remove duplicate video frames caused by WCE-s imaging nature,
such as repetitive forward-backward motions from peristaltic
movements. The motion vectors are derived by calculating
directional component vectors in four local regions. Our
experiments are performed on small intestine area, which is of
main interest to clinical experts when using WCEs, and our
experimental results show significant frame reductions comparing
with a simple frame-to-frame similarity-based image reduction
method.
Abstract: BioEnergy is an archetypal appropriate technology
and alternate source of energy in rural areas of China, and can meet
the basic need for cooking fuel in rural areas. The paper introduces
with an alternate mean of research that can accelerate the biogas
energy production. Tithonia diversifolia or the Tree marigold can be
hailed as mesophillic anaerobic digestion to increase the production
of more Bioenergy. Tithonia diversifolia is very native to Mexico and
Central America, which can be served as ornamental plants- green
manure and can prevent soil erosion. Tithonia diversifolia is widely
grown and known to Asia, Africa, America and Australia as well.
Nowadays, Considering China’s geographical condition it is found
that Tithonia diversifolia is widely growing plant in the many tropical
and subtropical regions of southern Yunnan- which can have great
usage in accelerating and increasing the Bioenergy production
technology. The paper discussed aiming at proving possibility that
Tithonia diversifolia can be applied in biogas fermentation and its
biogas production potential, the research carried experiment on
Tithonia diversifolia biogas fermentation under the mesophilic
condition (35 Celsius Degree). The result revealed that Tithonia
diversifolia can be used as biogas fermentative material, and 6%
concentration can get the best biogas production, with the TS biogas
production rate 656mL/g and VS biogas production rate 801mL/g. It
is well addressed that Tithonia diversifolia grows wildly in 53
Counties and 9 cities of Yunnan Province, which mainly grows in
form of the road side plants, the edge of the field, countryside, forest
edge, open space; of which demersum-natures can form dense
monospecific beds -causing serious harm to agricultural production
landforms threatening the ecological system as a potentially harmful
exotic plant. There are also found the three types of invasive daisy
alien plants -Eupatorium adenophorum, Eupatorium Odorata and
Tithonia diversifolia in Yunnan Province of China-among them the
Tithonia diversifolia is responsible for causing serious harm to
agricultural production. In this paper we have designed the
experimental explanation of Biogas energy production that requires
anaerobic environment and some microbes; Tithonia diversifolia
plant has been taken into consideration while carrying experiments
and with successful resulting of generating more BioEnergy
emphasizing on the practical applications of Tithonia diversifolia.
This paper aims at- to find a new mechanism to provide a more
scientific basis for the development of this plant herbicides in Biogas
energy and to improve the utilization throughout the world as well.
Abstract: Blood pulse is an important human physiological signal commonly used for the understanding of the individual physical health. Current methods of non-invasive blood pulse sensing require direct contact or access to the human skin. As such, the performances of these devices tend to vary with time and are subjective to human body fluids (e.g. blood, perspiration and skin-oil) and environmental contaminants (e.g. mud, water, etc). This paper proposes a simulation model for the novel method of non-invasive acquisition of blood pulse using the disturbance created by blood flowing through a localized magnetic field. The simulation model geometry represents a blood vessel, a permanent magnet, a magnetic sensor, surrounding tissues and air in 2-dimensional. In this model, the velocity and pressure fields in the blood stream are described based on Navier-Stroke equations and the walls of the blood vessel are assumed to have no-slip condition. The blood assumes a parabolic profile considering a laminar flow for blood in major artery near the skin. And the inlet velocity follows a sinusoidal equation. This will allow the computational software to compute the interactions between the magnetic vector potential generated by the permanent magnet and the magnetic nanoparticles in the blood. These interactions are simulated based on Maxwell equations at the location where the magnetic sensor is placed. The simulated magnetic field at the sensor location is found to assume similar sinusoidal waveform characteristics as the inlet velocity of the blood. The amplitude of the simulated waveforms at the sensor location are compared with physical measurements on human subjects and found to be highly correlated.
Abstract: Nothing that an effective cure for infertility happens
when we can find a unique solution, a great deal of study has been
done in this field and this is a hot research subject for to days study.
So we could analyze the men-s seaman and find out about fertility
and infertility and from this find a true cure for this, since this will be
a non invasive and low risk procedure, it will be greatly welcomed.
In this research, the procedure has been based on few Algorithms
enhancement and segmentation of images which has been done on
the images taken from microscope in different fertility institution and
have obtained a suitable result from the computer images which in
turn help us to distinguish these sperms from fluids and its
surroundings.
Abstract: Functional Magnetic Resonance Imaging(fMRI) is a
noninvasive imaging technique that measures the hemodynamic
response related to neural activity in the human brain. Event-related
functional magnetic resonance imaging (efMRI) is a form of
functional Magnetic Resonance Imaging (fMRI) in which a series of
fMRI images are time-locked to a stimulus presentation and averaged
together over many trials. Again an event related potential (ERP) is a
measured brain response that is directly the result of a thought or
perception. Here the neuronal response of human visual cortex in
normal healthy patients have been studied. The patients were asked
to perform a visual three choice reaction task; from the relative
response of each patient corresponding neuronal activity in visual
cortex was imaged. The average number of neurons in the adult
human primary visual cortex, in each hemisphere has been estimated
at around 140 million. Statistical analysis of this experiment was
done with SPM5(Statistical Parametric Mapping version 5) software.
The result shows a robust design of imaging the neuronal activity of
human visual cortex.
Abstract: This work proposes an optical fiber system (OF) for
sensing various volatile organic compounds (VOCs) in human breath
for the diagnosis of some metabolic disorders as a non-invasive
methodology. The analyzed VOCs are alkanes (i.e., ethane, pentane,
heptane, octane, and decane), and aromatic compounds (i.e., benzene,
toluene, and styrene). The OF displays high analytical performance
since it provides near real-time responses, rapid analysis, and low
instrumentation costs, as well as it exhibits useful linear range and
detection limits; the developed OF sensor is also comparable to a
reference methodology (gas chromatography-mass spectrometry) for
the eight tested VOCs.
Abstract: This paper presents an experimental case using sensory thermography to describe temperatures behavior on median nerve once an activity of repetitive motion was done. Thermography is a noninvasive technique without biological hazard and not harm at all times and has been applied in many experiments to seek for temperature patterns that help to understand diseases like cancer and cumulative trauma disorders (CTD’s). An infrared sensory thermography technology was developed to execute this study. Three women in good shape were selected for the repetitive motion tests for 4 days, two right-handed women and 1 left handed woman, two sensory thermographers were put on both median nerve wrists to get measures. The evaluation time was of 3 hours 30 minutes in a controlled temperature, 20 minutes of stabilization time at the beginning and end of the operation. Temperatures distributions are statistically evaluated and showed similar temperature patterns behavior.
Abstract: The present paper presents a finite element model and
analysis for the interaction between a piezoresistive tactile sensor and
biological tissues. The tactile sensor is proposed for use in minimally
invasive surgery to deliver tactile information of biological tissues to
surgeons. The proposed sensor measures the relative hardness of soft
contact objects as well as the contact force. Silicone rubbers were
used as the phantom of biological tissues. Finite element analysis of
the silicone rubbers and the mechanical structure of the sensor were
performed using COMSOL Multiphysics (v3.4) environment. The
simulation results verify the capability of the sensor to be used to
differentiate between different kinds of silicone rubber materials.