Abstract: This paper describes an automatic algorithm to restore
the shape of three-dimensional (3D) left ventricle (LV) models created
from magnetic resonance imaging (MRI) data using a geometry-driven
optimization approach. Our basic premise is to restore the LV shape
such that the LV epicardial surface is smooth after the restoration. A
geometrical measure known as the Minimum Principle Curvature (κ2)
is used to assess the smoothness of the LV. This measure is used to
construct the objective function of a two-step optimization process.
The objective of the optimization is to achieve a smooth epicardial
shape by iterative in-plane translation of the MRI slices.
Quantitatively, this yields a minimum sum in terms of the magnitude
of κ
2, when κ2 is negative. A limited memory quasi-Newton algorithm,
L-BFGS-B, is used to solve the optimization problem. We tested our
algorithm on an in vitro theoretical LV model and 10 in vivo
patient-specific models which contain significant motion artifacts. The
results show that our method is able to automatically restore the shape
of LV models back to smoothness without altering the general shape of
the model. The magnitudes of in-plane translations are also consistent
with existing registration techniques and experimental findings.
Abstract: Artifact free photoplethysmographic (PPG) signals are
necessary for non-invasive estimation of oxygen saturation (SpO2) in
arterial blood. Movement of a patient corrupts the PPGs with motion
artifacts, resulting in large errors in the computation of Sp02. This
paper presents a study on using Kalman Filter in an innovative way
by modeling both the Artillery Blood Pressure (ABP) and the
unwanted signal, additive motion artifact, to reduce motion artifacts
from corrupted PPG signals. Simulation results show acceptable
performance regarding LMS and variable step LMS, thus
establishing the efficacy of the proposed method.
Abstract: Electromyography (EMG) is the study of muscles function through analysis of electrical activity produced from muscles. This electrical activity which is displayed in the form of signal is the result of neuromuscular activation associated with muscle contraction. The most common techniques of EMG signal recording are by using surface and needle/wire electrode where the latter is usually used for interest in deep muscle. This paper will focus on surface electromyogram (SEMG) signal. During SEMG recording, several problems had to been countered such as noise, motion artifact and signal instability. Thus, various signal processing techniques had been implemented to produce a reliable signal for analysis. SEMG signal finds broad application particularly in biomedical field. It had been analyzed and studied for various interests such as neuromuscular disease, enhancement of muscular function and human-computer interface.