Abstract: One of the main purposes of designing bucklingrestrained
braces is the fact that the entire lateral load is wasted by
the braces, the entire gravitational load is moved to the foundation
through the beams, and the columns can be moved to the foundation.
In other words, braces are designed for bearing lateral load. In the
implementation of the structure, it should be noted that the
implementation of various parts of the structure must be conducted in
such a way that the buckling-restrained braces would not bear the
gravitational load. Moreover, this type of brace has been investigated
under impact loading, and the design goals of designing method
(direct motion) are controlled under impact loading. The results of
dynamic analysis are shown as the relocation charts of the floors and
switch between the floors. Finally, the results are compared with each
other.
Abstract: A physical model for guiding the wave in
photorefractive media is studied. Propagation of cos-Gaussian beam
as the special cases of sinusoidal-Gaussian beams in photorefractive
crystal is simulated numerically by the Crank-Nicolson method in
one dimension. Results show that the beam profile deforms as the
energy transfers from the center to the tails under propagation. This
simulation approach is of significant interest for application in optical
telecommunication. The results are presented graphically and
discussed.
Abstract: Microcantilevers are the basic MEMS devices, which
can be used as sensors, actuators and electronics can be easily built
into them. The detection principle of microcantilever sensors is based
on the measurement of change in cantilever deflection or change in its
resonance frequency. The objective of this work is to explore the
analogies between mechanical and electrical equivalent of
microcantilever beams. Normally scientists and engineers working in
MEMS use expensive software like CoventorWare, IntelliSuite,
ANSYS/Multiphysics etc. This paper indicates the need of developing
electrical equivalent of the MEMS structure and with that, one can
have a better insight on important parameters, and their interrelation of
the MEMS structure. In this work, considering the mechanical model
of microcantilever, equivalent electrical circuit is drawn and using
force-voltage analogy, it is analyzed with circuit simulation software.
By doing so, one can gain access to powerful set of intellectual tools
that have been developed for understanding electrical circuits Later
the analysis is performed using ANSYS/Multiphysics - software based
on finite element method (FEM). It is observed that both mechanical
and electrical domain results for a rectangular microcantlevers are in
agreement with each other.
Abstract: The floor beams of steel buildings, cold-formed steel
floor joists in particular, often require large web openings, which may
affect their shear capacities. A cost effective way to mitigate the
detrimental effects of such openings is to weld/fasten reinforcements.
A difficulty associated with an experimental investigation to establish
suitable reinforcement schemes for openings in shear zone is that
moment always coexists with the shear, and thus, it is impossible to
create pure shear state in experiments, resulting in moment
influenced results. However, Finite Element Method (FEM) based
analysis can be conveniently used to investigate the pure shear
behaviour of webs including webs with reinforced openings. This
paper presents the details associated with the finite element analysis
of thick/thin-plates (representing the web of hot-rolled steel beam,
and the web of a cold-formed steel member) having a large
reinforced opening. The study considered simply-supported
rectangular plates subjected to in-plane shear loadings until failure
(including post-buckling behaviour). The plate was modelled using
geometrically non-linear quadrilateral shell elements, and non-linear
stress-strain relationship based on experiments. Total Langrangian
with large displacement/small strain formulation was used for such
analyses. The model also considered the initial geometric
imperfections. This study considered three reinforcement schemes,
namely, flat, lip, and angle reinforcements. This paper discusses the
modelling considerations and presents the results associated with the
various reinforcement schemes under consideration.
Abstract: Lateral torsional buckling is a global buckling mode
which should be considered in design of slender structural members
under flexure about their strong axis. It is possible to compute the
load which causes lateral torsional buckling of a beam by finite
element analysis, however, closed form equations are needed in
engineering practice for calculation ease which can be obtained by
using energy method. In lateral torsional buckling applications of
energy method, a proper function for the critical lateral torsional
buckling mode should be chosen which can be thought as the
variation of twisting angle along the buckled beam. Accuracy of the
results depends on how close is the chosen function to the exact
mode. Since critical lateral torsional buckling mode of the cantilever
I-beams varies due to material properties, section properties and
loading case, the hardest step is to determine a proper mode function
in application of energy method. This paper presents an approximate function for critical lateral
torsional buckling mode of doubly symmetric cantilever I-beams.
Coefficient matrices are calculated for concentrated load at free end,
uniformly distributed load and constant moment along the beam
cases. Critical lateral torsional buckling modes obtained by presented
function and exact solutions are compared. It is found that the modes
obtained by presented function coincide with differential equation
solutions for considered loading cases.
Abstract: The paper aims at investigating the effect of number
of story on different structural components of reinforced concrete
building due to gravity and lateral loading. For the study, three
building models having same building plan of three, six and nine
stories are analyzed and designed using software package. All the
buildings are residential and are located in Dhaka city of Bangladesh.
Lateral load including wind and earthquake loading are applied to the
building along both longitudinal and transverse direction as per
Bangladesh National Building Code (BNBC, 2006). Equivalent static
force method is followed for the applied seismic loading. The present
study investigates as well as compares mainly total steel requirement
in different structural components for those buildings. It has been
found that total longitudinal steel requirement for beams at each floor
is 48.57% for three storied building, 61.36% for six storied building
when the total percentage is taken as 100% in case of nine storied
building. For an exterior column, the steel ratio is 2.1%, 3.06%,
4.55% for three, six and nine storied building respectively for the first
three floors. In addition, it has been noted that total weight of
longitudinal reinforcement of an interior column is 14.02 % for threestoried
building and 43.12% for six storied building when the total
reinforcement is considered 100% for nine storied building for the
first three floors.
Abstract: The study conducted a simulation of the effect of sea
water to the bonding capacity of GFRP sheet on the concrete beams
using a simulation tank. Fiber reinforced polymer (FRP) has been
developed and applied in many fields civil engineering structures on
the new structures and also for strengthening of the deteriorated
structures. The FRP has advantages such as its corrosion resistance as
well as high tensile strength to weight ratio. Compared to the other
FRP materials, Glass composed FRP (GFRP) is relatively cheaper.
GFRP sheet is applied externally by bonding it on the concrete surface.
The studies regarding the application of GFRP sheet have been
conducted such as strengthening system, bonding behavior of GFRP
sheet including the application as reinforcement in new structures. For
application to the structures with direct contact to sea environment, a
study regarding the effect of sea water to the bonding capacity of
GFRP sheet is important to be clarified. To achieve the objective of the
study, a series of concrete beams strengthened with GFRP sheet on
extreme tension surface were prepared. The beams then were stored on
the sea water tank for six months. Results indicated the bonding
capacity decreased after six month exposed to the sea water.
Abstract: The reheating furnace is used to reheat the steel slabs
before the hot-rolling process. The supported system includes the
stationary/moving beams, and the skid buttons which block some
thermal radiation transmitted to the bottom of the slabs. Therefore, it is
important to analyze the steel slab temperature distribution during the
heating period. A three-dimensional mathematical transient heat
transfer model for the prediction of temperature distribution within the
slab has been developed. The effects of different skid button height
(H=60mm, 90mm, and 120mm) and different gap distance between
two slabs (S=50mm, 75mm, and 100mm) on the slab skid mark
formation and temperature profiles are investigated. Comparison with
the in-situ experimental data from Steel Company in Taiwan shows
that the present heat transfer model works well for the prediction of
thermal behavior of the slab in the reheating furnace. It is found that
the skid mark severity decreases with an increase in the skid button
height. The effect of gap distance is important only for the slab edge
planes, while it is insignificant for the slab central planes.
Abstract: In the present study we have investigated axial
buckling characteristics of nanocomposite beams reinforced by
single-walled carbon nanotubes (SWCNTs). Various types of beam
theories including Euler-Bernoulli beam theory, Timoshenko beam
theory and Reddy beam theory were used to analyze the buckling
behavior of carbon nanotube-reinforced composite beams.
Generalized differential quadrature (GDQ) method was utilized to
discretize the governing differential equations along with four
commonly used boundary conditions. The material properties of the
nanocomposite beams were obtained using molecular dynamic (MD)
simulation corresponding to both short-(10,10) SWCNT and long-
(10,10) SWCNT composites which were embedded by amorphous
polyethylene matrix. Then the results obtained directly from MD
simulations were matched with those calculated by the mixture rule
to extract appropriate values of carbon nanotube efficiency
parameters accounting for the scale-dependent material properties.
The selected numerical results were presented to indicate the
influences of nanotube volume fractions and end supports on the
critical axial buckling loads of nanocomposite beams relevant to
long- and short-nanotube composites.
Abstract: This paper aims to determine Fundamental Natural
Frequency (FNF) of a structural composite floor system known as
Chromite. To achieve this purpose, FNFs of studied panels are
determined by development of Finite Element Models (FEMs) in
ABAQUS program. American Institute of Steel Construction (AISC)
code in Steel Design Guide Series 11 presents a fundamental formula
to calculate FNF of a steel framed floor system. This formula has
been used to verify results of the FEMs. The variability in the FNF of
the studied system under various parameters such as dimensions of
floor, boundary conditions, rigidity of main and secondary beams
around the floor, thickness of concrete slab, height of composite
joists, distance between composite joists, thickness of top and bottom
flanges of the open web steel joists, and adding tie beam
perpendicular on the composite joists, is determined. The results
show that changing in dimensions of the system, its boundary
conditions, rigidity of main beam, and also adding tie beam,
significant changes the FNF of the system up to 452.9%, 50.8%, -
52.2%, %52.6%, respectively. In addition, increasing thickness of
concrete slab increases the FNF of the system up to 10.8%.
Furthermore, the results demonstrate that variation in rigidity of
secondary beam, height of composite joist, and distance between
composite joists, and thickness of top and bottom flanges of open
web steel joists insignificant changes the FNF of the studied system
up to -0.02%, -3%, -6.1%, and 0.96%, respectively. Finally, the
results of this study help designer predict occurrence of resonance,
comfortableness, and design criteria of the studied system.
Abstract: This paper studies a mathematical model based on the
integral equations for dynamic analyzes numerical investigations of a
non-uniform or multi-material composite beam. The beam is
subjected to a sub-tangential follower force and elastic foundation.
The boundary conditions are represented by generalized
parameterized fixations by the linear and rotary springs. A
mathematical formula based on Euler-Bernoulli beam theory is
presented for beams with variable cross-sections. The non-uniform
section introduces non-uniformity in the rigidity and inertia of beams
and consequently, more complicated equilibrium who governs the
equation. Using the boundary element method and radial basis
functions, the equation of motion is reduced to an algebro-differential
system related to internal and boundary unknowns. A generalized
formula for the deflection, the slope, the moment and the shear force
are presented. The free vibration of non-uniform loaded beams is
formulated in a compact matrix form and all needed matrices are
explicitly given. The dynamic stability analysis of slender beam is
illustrated numerically based on the coalescence criterion. A realistic
case related to an industrial chimney is investigated.
Abstract: The purpose of this research was to investigate the
creep behaviour of the heterogeneous Timber-UHPFRC beams. New
developments have been done to further improve the structural
performance, such as strengthening of the timber (glulam) beam by
bonding composite material combine with an ultra-high performance
fibre reinforced concrete (UHPFRC) internally reinforced with or
without carbon fibre reinforced polymer (CFRP) bars. However, in
the design of wooden structures, in addition to the criteria of
strengthening and stiffness, deformability due to the creep of wood,
especially in horizontal elements, is also a design criterion. Glulam,
UHPFRC and CFRP may be an interesting composite mix to respond
to the issue of creep behaviour of composite structures made of
different materials with different rheological properties. In this paper,
we describe an experimental and analytical investigation of the creep
performance of the glulam-UHPFRC-CFRP beams assembled by
bonding. The experimental investigations creep behaviour was
conducted for different environments: in- and outside under constant
loading for approximately a year. The measured results are compared
with numerical ones obtained by an analytical model. This model was
developed to predict the creep response of the glulam-UHPFRCCFRP
beams based on the creep characteristics of the individual
components. The results show that heterogeneous glulam-UHPFRC
beams provide an improvement in both the strengthening and
stiffness, and can also effectively reduce the creep deflection of
wooden beams.
Abstract: The current study aims to highlight the loading
characteristics impact on the time evolution (focusing particularly on
long term effects) of the deformation of realized reinforced concrete
beams. Namely the tension stiffening code provisions (i.e. within
Eurocode 2) are reviewed with a clear intention to reassess their
operational value and predicting capacity. In what follows the
experimental programme adopted along with some preliminary
findings and numerical modeling attempts are presented. For a range of long slender reinforced concrete simply supported
beams (4200 mm) constant static sustained and repeated cyclic
loadings were applied mapping the time evolution of deformation.
All experiments were carried out at the Heavy Structures Lab of the
University of Leeds. During tests the mid-span deflection, creep
coefficient and shrinkage strains were monitored for duration of 90
days. The obtained results are set against the values predicted by
Eurocode 2 and the tools within an FE commercial package (i.e.
Midas FEA) to yield that existing knowledge and practise is at times
over-conservative.
Abstract: When high strength reinforced concrete is exposed to
high temperature due to a fire, deteriorations occur such as loss in
strength and elastic modulus, cracking and spalling of the concrete.
Therefore, it is important to understand risk of structural safety in
building structures by studying structural behaviors and rehabilitation
of fire damaged high strength concrete structures. This paper aims at
investigating rehabilitation effect on fire damaged high strength
concrete beams using experimental and analytical methods. In the
experiments, flexural specimens with high strength concrete are
exposed to high temperatures according to ISO 834 standard time
temperature curve. From four-point loading test, results show that
maximum loads of the rehabilitated beams are similar to or higher than
those of the non-fire damaged RC beam. In addition, structural
analyses are performed using ABAQUS 6.10-3 with same conditions
as experiments to provide accurate predictions on structural and
mechanical behaviors of rehabilitated RC beams. The parameters are
the fire cover thickness and strengths of repairing mortar. Analytical
results show good rehabilitation effects, when the results predicted
from the rehabilitated models are compared to structural behaviors of
the non-damaged RC beams. In this study, fire damaged high strength concrete beams are
rehabilitated using polymeric cement mortar. The predictions from the
finite element (FE) models show good agreements with the
experimental results and the modeling approaches can be used to
investigate applicability of various rehabilitation methods for further
study.
Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: In this paper, analysis of an infinite beam resting on
multilayer tensionless extensible geosynthetic reinforced granular
fill-poor soil system overlying soft soil strata under moving load with
constant velocity is presented. The beam is subjected to a
concentrated load moving with constant velocity. The upper
reinforced granular bed is modeled by a rough membrane embedded
in Pasternak shear layer overlying a series of compressible nonlinear
winkler springs representing the underlying the very poor soil. The
multilayer tensionless extensible geosynthetic layer has been
assumed to deform such that at interface the geosynthetic and the soil
have some deformation. Nonlinear behaviour of granular fill and the
very poor soil has been considered in the analysis by means of
hyperbolic constitutive relationships. Governing differential
equations of the soil foundation system have been obtained and
solved with the help of appropriate boundary conditions. The solution
has been obtained by employing finite difference method by means of
Gauss-Siedal iterative scheme. Detailed parametric study has been
conducted to study the influence of various parameters on the
response of soil–foundation system under consideration by means of
deflection and bending moment in the beam and tension mobilized in
the geosynthetic layer. These parameters include magnitude of
applied load, velocity of load, damping, ultimate resistance of poor
soil and granular fill layer. Range of values of parameters has been
considered as per Indian Railway conditions. This study clearly
observed that the comparisons of multilayer tensionless extensible
geosynthetic reinforcement with poor foundation soil and magnitude
of applied load, relative compressibility of granular fill and ultimate
resistance of poor soil has significant influence on the response of
soil–foundation system.
Abstract: In recent years, fire accidents have been steadily
increased and the amount of property damage caused by the accidents
has gradually raised. Damaging building structure, fire incidents bring
about not only such property damage but also strength degradation and
member deformation. As a result, the building structure undermines its
structural ability. Examining the degradation and the deformation is
very important because reusing the building is more economical than
reconstruction. Therefore, engineers need to investigate the strength
degradation and member deformation well, and make sure that they
apply right rehabilitation methods. This study aims at evaluating
deformation characteristics of fire damaged and rehabilitated normal
strength concrete beams through both experiments and finite element
analyses. For the experiments, control beams, fire damaged beams and
rehabilitated beams are tested to examine deformation characteristics.
Ten test beam specimens with compressive strength of 21MPa are
fabricated and main test variables are selected as cover thickness of
40mm and 50mm and fire exposure time of 1 hour or 2 hours. After
heating, fire damaged beams are air-recurred for 2 months and
rehabilitated beams are repaired with polymeric cement mortar after
being removed the fire damaged concrete cover. All beam specimens
are tested under four points loading. FE analyses are executed to
investigate the effects of main parameters applied to experimental
study. Test results show that both maximum load and stiffness of the
rehabilitated beams are higher than those of the fire damaged beams.
In addition, predicted structural behaviors from the analyses also show
good rehabilitation effect and the predicted load-deflection curves are
similar to the experimental results. For the further, the proposed
analytical method can be used to predict deformation characteristics of
fire damaged and rehabilitated concrete beams without suffering from
time and cost consuming of experimental process.
Abstract: In recent years, honeycomb fiber reinforced plastic
(FRP) sandwich panels have been increasingly used in various
industries. Low weight, low price and high mechanical strength are
the benefits of these structures. However, their mechanical properties
and behavior have not been fully explored. The objective of this
study is to conduct a combined numerical-statistical investigation of
honeycomb FRP sandwich beams subject to torsion load. In this
paper, the effect of geometric parameters of sandwich panel on
maximum shear strain in both face and core and angle of torsion in a
honeycomb FRP sandwich structures in torsion is investigated. The
effect of Parameters including core thickness, face skin thickness,
cell shape, cell size, and cell thickness on mechanical behavior of the
structure were numerically investigated. Main effects of factors were
considered in this paper and regression equations were derived.
Taguchi method was employed as experimental design and an
optimum parameter combination for the maximum structure stiffness
has been obtained. The results showed that cell size and face skin
thickness have the most significant impacts on torsion angle,
maximum shear strain in face and core.
Abstract: Numerical investigations were conducted to study the
influence of flexural reinforcement ratio on the diagonal cracking
strength and ultimate shear strength of reinforced concrete (RC)
beams without stirrups. Three-dimensional nonlinear finite element
analyses (FEAs) of the beams with flexural reinforcement ratios
ranging from 0.58% to 2.20% subjected to a mid-span concentrated
load were carried out. It is observed that the load-deflection and loadstrain
curves obtained from the numerical analyses agree with those
obtained from the experiments. It is concluded that flexural
reinforcement ratio has a significant effect on the shear strength and
deflection capacity of RC beams without stirrups. The predictions of
diagonal cracking strength and ultimate shear strength of beams
obtained by using the equations defined by a number of codes and
researchers are compared with each other and with the experimental
values.
Abstract: We investigate experimentally and theoretically the
dynamics of a capacitive resonator under mixed frequency excitation
of two AC harmonic signals. The resonator is composed of a proof
mass suspended by two cantilever beams. Experimental
measurements are conducted using a laser Doppler Vibrometer to
reveal the interesting dynamics of the system when subjected to twosource
excitation. A nonlinear single-degree-of-freedom model is
used for the theoretical investigation. The results reveal combination
resonances of additive and subtractive type, which are shown to be
promising to increase the bandwidth of the resonator near primary
resonance frequency. Our results also demonstrate the ability to shift
the combination resonances to much lower or much higher frequency
ranges. We also demonstrate the dynamic pull-in instability under
mixed frequency excitation.