Abstract: The end panels of a large rectangular industrial duct,
which experience significant internal pressures, also experience
considerable transverse shear due to transfer of gravity loads to the
supports. The current design practice of such thin plate panels for
shear load is based on methods used for the design of plate girder
webs. The structural arrangements, the loadings and the resulting
behavior associated with the industrial duct end panels are, however,
significantly different from those of the web of a plate girder. The
large aspect ratio of the end panels gives rise to multiple bands of
tension fields, whereas the plate girder web design is based on one
tension field. In addition to shear, the industrial end panels are
subjected to internal pressure which in turn produces significant
membrane action. This paper reports a study which was undertaken
to review the current industrial analysis and design methods and to
propose a comprehensive method of designing industrial duct end
panels for shear resistance. In this investigation, a nonlinear finite element model was
developed to simulate the behavior of industrial duct end panel, along
with the associated edge stiffeners, subjected to transverse shear and
internal pressures. The model considered the geometric imperfections
and constitutive relations for steels. Six scale independent
dimensionless parameters that govern the behavior of such end panel
were identified and were then used in a parametric study. It was
concluded that the plate slenderness dominates the shear strength of
stockier end panels, and whereas, both the plate slenderness and the
aspect ratio influence the shear strength of slender end panels. Based
on these studies, this paper proposes design aids for estimating the
shear strength of rectangular duct end panels.
Abstract: The floor beams of steel buildings, cold-formed steel
floor joists in particular, often require large web openings, which may
affect their shear capacities. A cost effective way to mitigate the
detrimental effects of such openings is to weld/fasten reinforcements.
A difficulty associated with an experimental investigation to establish
suitable reinforcement schemes for openings in shear zone is that
moment always coexists with the shear, and thus, it is impossible to
create pure shear state in experiments, resulting in moment
influenced results. However, Finite Element Method (FEM) based
analysis can be conveniently used to investigate the pure shear
behaviour of webs including webs with reinforced openings. This
paper presents the details associated with the finite element analysis
of thick/thin-plates (representing the web of hot-rolled steel beam,
and the web of a cold-formed steel member) having a large
reinforced opening. The study considered simply-supported
rectangular plates subjected to in-plane shear loadings until failure
(including post-buckling behaviour). The plate was modelled using
geometrically non-linear quadrilateral shell elements, and non-linear
stress-strain relationship based on experiments. Total Langrangian
with large displacement/small strain formulation was used for such
analyses. The model also considered the initial geometric
imperfections. This study considered three reinforcement schemes,
namely, flat, lip, and angle reinforcements. This paper discusses the
modelling considerations and presents the results associated with the
various reinforcement schemes under consideration.