Abstract: The reheating furnace is used to reheat the steel slabs
before the hot-rolling process. The supported system includes the
stationary/moving beams, and the skid buttons which block some
thermal radiation transmitted to the bottom of the slabs. Therefore, it is
important to analyze the steel slab temperature distribution during the
heating period. A three-dimensional mathematical transient heat
transfer model for the prediction of temperature distribution within the
slab has been developed. The effects of different skid button height
(H=60mm, 90mm, and 120mm) and different gap distance between
two slabs (S=50mm, 75mm, and 100mm) on the slab skid mark
formation and temperature profiles are investigated. Comparison with
the in-situ experimental data from Steel Company in Taiwan shows
that the present heat transfer model works well for the prediction of
thermal behavior of the slab in the reheating furnace. It is found that
the skid mark severity decreases with an increase in the skid button
height. The effect of gap distance is important only for the slab edge
planes, while it is insignificant for the slab central planes.
Abstract: A three-dimensional numerical model of
thermoelectric generator (TEG) modules attached to a large chimney
plate is proposed and solved numerically using a control volume based
finite difference formulation. The TEG module consists of a
thermoelectric generator, an elliptical pin-fin heat sink, and a cold
plate for water cooling. In the chimney, the temperature of flue gases is
450-650K. Although the TEG hot-side temperature and thus the
electric power output can be increased by inserting an elliptical pin-fin
heat sink into the chimney tunnel to increase the heat transfer area, the
pin fin heat sink would cause extra pumping power at the same time.
The main purpose of this study is to analyze the effects of geometrical
parameters on the electric power output and chimney pressure drop
characteristics. The effects of different operating conditions, including
various inlet velocities (Vin= 1, 3, 5 m/s), inlet temperatures (Tgas = 450,
550, 650K) and different fin height (0 to 150 mm) are discussed in
detail. The predicted numerical data for the power vs. current (P-I)
curve are in good agreement (within 11%) with the experimental data.