Abstract: Sustainable tall buildings that provide comfortable,
healthy and efficient indoor environments are clearly desirable as the
densification of living and working space for the world’s increasing
population proceeds. For environmental concerns, these buildings
must also be energy efficient. One component of these tasks is the
provision of indoor air quality and thermal comfort, which can be
enhanced with natural ventilation by the supply of fresh air. Working
spaces can only be naturally ventilated with connections to the
outdoors utilizing operable windows, double facades, ventilation
stacks, balconies, patios, terraces and skygardens. Large amounts of
fresh air can be provided to the indoor spaces without mechanical
air-conditioning systems, which are widely employed in
contemporary tall buildings.
This paper tends to present the concept of natural ventilation for
sustainable tall office buildings in order to achieve healthy and
comfortable working spaces, as well as energy efficient
environments. Initially the historical evolution of ventilation
strategies for tall buildings is presented, beginning with natural
ventilation and continuing with the introduction of mechanical airconditioning
systems. Then the emergence of natural ventilation due
to the health and environmental concerns in tall buildings is handled,
and the strategies for implementing this strategy are revealed. In the
next section, a number of case studies that utilize this strategy are
investigated. Finally, how tall office buildings can benefit from this
strategy is discussed.
Abstract: The work presented in this paper was performed for a workstation of an assembly section in a company that manufactures radio modules and air conditioning for cars. After performing a workstation analysis and a questionnaire to the operators it was possible to understand the need to investigate the risk of musculoskeletal disorders originated from both the handling of loads as the incorrect dimensioning of the workstation. Regarding the handling of loads the NIOSH Equation was used and it was verified that there was no risk of musculoskeletal disorders. As the operators expressed their lack of satisfaction regarding back pains due to posture adopted they were established the appropriate dimensions (to satisfy 97.5% of the population and using the table of anthropometric data of the Portuguese population) for the workstation and it was proposed the availability of a chair for the workers.
Abstract: Pressure loss in ductworks is an important factor to be considered in design of engineering systems such as power-plants, refineries, HVAC systems to reduce energy costs. Ductwork can be composed by straight ducts and different types of fittings (elbows, transitions, converging and diverging tees and wyes). Duct fittings are significant sources of pressure loss in fluid distribution systems. Fitting losses can be even more significant than equipment components such as coils, filters, and dampers. At the present work, a conventional 90o round elbow under turbulent incompressible airflow is studied. Mass, momentum, and k-e turbulence model equations are solved employing the finite volume method. The SIMPLE algorithm is used for the pressure-velocity coupling. In order to validate the numerical tool, the elbow pressure loss coefficient is determined using the same conditions to compare with ASHRAE database. Furthermore, the effect of Reynolds number variation on the elbow pressure loss coefficient is investigated. These results can be useful to perform better preliminary design of air distribution ductworks in air conditioning systems.
Abstract: Hospitals represent approximately 6% of total energy consumption in the utility buildings sector. Heating, Ventilation and Air Conditioning (HVAC) systems are the major part of electrical energy consumption at the hospitals. The air-conditioning system is responsible for around 70% of total electricity consumption. Electric motors and lighting systems in a hospital represent approximately 19% and 21% of the total energy consumption, respectively. In this paper, profiles of hospital energy end-use consumption and an overview of energy saving areas at the hospitals are presented.
Abstract: In this paper, supply air pressure of HVAC system has been modeled with second-order transfer function plus dead-time. In HVAC system, the desired input has step changes, and the output of proposed control system should be able to follow the input reference, so the idea of using model based predictive control is proceeded and designed in this paper. The closed loop control system is implemented in MATLAB software and the simulation results are provided. The simulation results show that the model based predictive control is able to control the plant properly.
Abstract: Demand response is getting increased attention these days due to the increase in electricity demand and introduction of renewable resources in the existing power grid. Traditionally demand response programs involve large industrial consumers but with technological advancement, demand response is being implemented for small residential and commercial consumers also. In this paper, demand response program aims to reduce the peak demand as well as overall energy consumption of the residential customers. Air conditioners are the major reason of peak load in residential sector in summer, so a dynamic model of air conditioning load with thermostat action has been considered for applying demand response programs. A programmable communicating thermostat (PCT) is a device that uses real time pricing (RTP) signals to control the thermostat setting. A new model incorporating PCT in air conditioning load has been proposed in this paper. Results show that introduction of PCT in air conditioner is useful in reducing the electricity payments of customers as well as reducing the peak demand.
Abstract: This paper deals the energy saving performance of GHP (Gas engine heat pump) air conditioning system has improved with time-series variation. There are two types of air conditioning systems, VRF (Variable refrigerant flow) and central cooling and heating system. VRF is classified as EHP (Electric driven heat pump) and GHP. EHP drives the compressor with electric motor. GHP drives the compressor with the gas engine. The electric consumption of GHP is less than one tenth of EHP does.
In this study, the energy consumption data of GHP installed the junior high schools was collected. An annual and monthly energy consumption per rated thermal output power of each apparatus was calculated, and then their energy efficiency was analyzed. From these data, we investigated improvement of the energy saving of the GHP air conditioning system by the change in the generation.
Abstract: The objective of this study is to present the test
results of variable air volume (VAV) air conditioning system
optimized by two objective genetic algorithm (GA). The objective
functions are energy savings and thermal comfort. The optimal set
points for fuzzy logic controller (FLC) are the supply air temperature
(Ts), the supply duct static pressure (Ps), the chilled water
temperature (Tw), and zone temperature (Tz) that is taken as the
problem variables. Supply airflow rate and chilled water flow rate are
considered to be the constraints. The optimal set point values are
obtained from GA process and assigned into fuzzy logic controller
(FLC) in order to conserve energy and maintain thermal comfort in
real time VAV air conditioning system. A VAV air conditioning
system with FLC installed in a software laboratory has been taken for
the purpose of energy analysis. The total energy saving obtained in
VAV GA optimization system with FLC compared with constant air
volume (CAV) system is expected to achieve 31.5%. The optimal
duct static pressure obtained through Genetic fuzzy methodology
attributes to better air distribution by delivering the optimal quantity
of supply air to the conditioned space. This combination enhanced
the advantages of uniform air distribution, thermal comfort and
improved energy savings potential.
Abstract: Cooling with sound is a physical phenomenon allowed by Thermo-Acoustics in which acoustic energy is transformed into a negative heat transfer, in other words: into cooling! Without needing any harmful gas, the transformation is environmentally friendly and can respond to many needs in terms of air conditioning, food refrigeration for domestic use, and cooling medical samples for example. To explore the possibilities of this cooling solution on a small scale, the TACS prototype has been designed, consisting of a low cost thermoacoustic refrigerant “pipe” able to lower the temperature by a few degrees. The obtained results are providing an interesting element for possible future of thermo-acoustic refrigeration.
Abstract: Having done in this study, air-conditioning
automation for patisserie shopwindow was designed. In the cooling
sector it is quite important to cooling up the air temperature in the
shopwindow within short time interval. Otherwise the patisseries
inside of the shopwindow will be spoilt in a few days. Additionally
the humidity is other important parameter for the patisseries kept in
shopwindow. It must be raised up to desired level in a quite short
time. Traditional patisserie shopwindows only allow controlling
temperature manually. There is no humidity control and humidity is
supplied by fans that are directed to the water at the bottom of the
shopwindows. In this study, humidity and temperature sensors
(SHT11), PIC, AC motor controller, DC motor controller, ultrasonic
nebulizer and other electronic circuit members were used to simulate
air conditioning automation for patisserie shopwindow in proteus
software package. The simulation results showed that temperature
and humidity values are adjusted in desired time duration by openloop
control technique. Outer and inner temperature and humidity
values were used for control mechanism.
Abstract: Air conditioning systems of houses consume large
quantity of electricity. To reducing energy consumption for air
conditioning purposes it is becoming attractive the use of evaporative
cooling air conditioning which is less energy consuming compared to
air chillers. But, it is obvious that higher energy efficiency of
evaporative cooling is not enough to judge whether evaporative
cooling economically is competitive with other types of cooling
systems. To proving the higher energy efficiency and cost
effectiveness of the evaporative cooling competitive analysis of
various types of cooling system should be accomplished. For noted
purpose optimization mathematical model for each system should be
composed based on system approach analysis. In this paper different
types of evaporative cooling-heating systems are discussed and
methods for increasing their energy efficiency and as well as
determining of their design parameters are developed. The
optimization mathematical models for each of them are composed
with help of which least specific costs for each of them are reviled.
The comparison of specific costs proved that the most efficient and
cost effective is considered the “direct evaporating" system if it is
applicable for given climatic conditions. Next more universal and
applicable for many climatic conditions system providing least cost
of heating and cooling is considered the “direct evaporating" system.
Abstract: Air conditioning is mainly to be used as human
comfort medium. It has been use more often in country in which the
daily temperatures are high. In scientific, air conditioning is defined
as a process of controlling the moisture, cooling, heating and cleaning
air. Without proper estimation of cooling load, big amount of waste
energy been used because of unsuitable of air conditioning system are
not considering to overcoming heat gains from surrounding. This is
due to the size of the room is too big and the air conditioning has to
use more energy to cool the room and the air conditioning is too
small for the room. The studies are basically to develop a program to
calculate cooling load. Through this study it is easy to calculate
cooling load estimation. Furthermore it-s help to compare the cooling
load estimation by hourly and yearly. Base on the last study that been
done, the developed software are not user-friendly. For individual
without proper knowledge of calculating cooling load estimation
might be problem. Easy excess and user-friendly should be the main
objective to design something. This program will allow cooling load
able be estimate by any users rather than estimation by using rule of
thumb. Several of limitation of case study is judged to sure it-s
meeting to Malaysia building specification. Finally validation is done
by comparison manual calculation and by developed program.
Abstract: The heat storage capacity of concrete in building shells is a major reason for excessively large electricity consumption induced by indoor air conditioning. In this research, the previously developed Smart Temperature Information Material (STIM) is embedded in two groups of exterior wall specimens (the control group contains reinforced concrete exterior walls and the experimental group consists of tiled exterior walls). Long term temperature measurements within the concrete are taken by the embedded STIM. Temperature differences between the control group and the experimental group in walls facing the four cardinal directions (east, west, south, and north) are evaluated. This study aims to provide a basic reference for the design of exterior walls and the selection of heat insulation materials.
Abstract: Energy consumption is a very important topic these
days especially regarding air conditioning in residential buildings,
since this takes the biggest amount of energy in buildings total
consumption, residential buildings constitute the biggest percentage
of energy consumption in Bahrain.
This research reflects on the effects of shading percentage in
different solar orientations on the energy consumption inside
residential buildings (domestic dwellings).
The research as found that, there are different effects of shading in
changing building orientation:
• 0.69% for the shading percentage 25% when the building is
oriented to the north (0º);
• 18.59% for 75% of shading in north-west orientation
(325º);
• The best effect for shading is in north-west orientation
(315º);
• The less effect for shading was in case of the building
orientation is the north (0º).
Abstract: Auckland has a temperate climate with comfortable
warm, dry summers and mild, wet winters. An Auckland school
normally does not need air conditioning for cooling during the
summer and only need heating during the winter. The space hating
energy is the major portion of winter school energy consumption and
the winter energy consumption is major portion of annual school
energy consumption. School building thermal design should focus
on the winter thermal performance for reducing the space heating
energy. A number of Auckland schools- design data and energy
consumption data are used for this study. This pilot study
investigates the relationships between their energy consumption data
and school building design data to improve future school design for
energy efficiency.
Abstract: In countries with hot climates, air-conditioning forms
a large proportion of annual peak electrical demand, requiring
expansion of power plants to meet the peak demand, which goes
unused most of the time. Use of well-designed cool storage can offset
the peak demand to a large extent. In this study, an air conditioning
system with naturally stratified storage tank was designed,
constructed and tested. A new type of diffuser was designed and used
in this study. Factors that influence the performance of chilled water
storage tanks were investigated. The results indicated that stratified
storage tank consistently stratified well without any physical barrier.
Investigation also showed that storage efficiency decreased with
increasing flow rate due to increased mixing of warm and chilled
water. Diffuser design and layout primarily affected the mixing near
the inlet diffuser and the extent of this mixing had primary influence
on the shape of the thermocline. The heat conduction through tank
walls and through the thermocline caused widening of mixed volume.
Thermal efficiency of stratified storage tanks was as high as 90
percent, which indicates that stratified tanks can effectively be used
as a load management technique.
Abstract: Current air conditioning system is using refrigerant as
the cooling medium. The main purpose of this study is to develop an
air conditioning system using chill water as the cooling medium. In
this system, chill water used to replace refrigerant as the cooling
medium. This study is focus on the split type unit air conditioning
system only. It will be involving some renovation on the indoor unit
and freezer. The cooling capability of this system was validate by few
series of testing, which conducted at standard 36m3 office room.
Result of the testing found that 0.1 m3 of chill water is able to
maintain the room temperature within standard up to 4 ~ 8 hours. It
expected able to maintain room temperature up to 10 hour with some
improvement.
Abstract: Evaporator is an important and widely used heat
exchanger in air conditioning and refrigeration industries. Different
methods have been used by investigators to increase the heat transfer
rates in evaporators. One of the passive techniques to enhance heat
transfer coefficient is the application of microfin tubes. The
mechanism of heat transfer augmentation in microfin tubes is
dependent on the flow regime of two-phase flow. Therefore many
investigations of the flow patterns for in-tube evaporation have been
reported in literatures. The gravitational force, surface tension and
the vapor-liquid interfacial shear stress are known as three dominant
factors controlling the vapor and liquid distribution inside the tube. A
review of the existing literature reveals that the previous
investigations were concerned with the two-phase flow pattern for
flow boiling in horizontal tubes [12], [9]. Therefore, the objective of
the present investigation is to obtain information about the two-phase
flow patterns for evaporation of R-134a inside horizontal smooth and
microfin tubes. Also Investigation of heat transfer during flow
boiling of R-134a inside horizontal microfin and smooth tube have
been carried out experimentally The heat transfer coefficients for
annular flow in the smooth tube is shown to agree well with Gungor
and Winterton-s correlation [4]. All the flow patterns occurred in the
test can be divided into three dominant regimes, i.e., stratified-wavy
flow, wavy-annular flow and annular flow. Experimental data are
plotted in two kinds of flow maps, i.e., Weber number for the vapor
versus weber number for the liquid flow map and mass flux versus
vapor quality flow map. The transition from wavy-annular flow to
annular or stratified-wavy flow is identified in the flow maps.
Abstract: Drop-in of R-22 alternatives in refrigeration and air conditioning systems requires a redesign of system components to improve system performance and reliability with the alternative refrigerants. The present paper aims at design adiabatic capillary tubes for R-22 alternatives such as R-417A, R-422D and R-438A. A theoretical model has been developed and validated with the available experimental data from literature for R-22 over a wide range of both operating and geometrical parameters. Predicted lengths of adiabatic capillary tube are compared with the lengths of the capillary tube needed under similar experimental conditions and majority of predictions are found to be within 4.4% of the experimental data. Hence, the model has been applied for R-417A, R- 422D and R-438A and capillary tube selection charts and correlations have been computed. Finally a comparison between the selected refrigerants and R-22 has been introduced and the results showed that R-438A is the closest one to R-22.
Abstract: The present paper was concerned primarily with the
analysis, simulation of the air flow and thermal patterns in a lecture
room. The paper is devoted to numerically investigate the influence
of location and number of ventilation and air conditioning supply and
extracts openings on air flow properties in a lecture room. The work
focuses on air flow patterns, thermal behaviour in lecture room where
large number of students. The effectiveness of an air flow system is
commonly assessed by the successful removal of sensible and latent
loads from occupants with additional of attaining air pollutant at a
prescribed level to attain the human thermal comfort conditions and
to improve the indoor air quality; this is the main target during the
present paper. The study is carried out using computational fluid
dynamics (CFD) simulation techniques as embedded in the
commercially available CFD code (FLUENT 6.2). The CFD
modelling techniques solved the continuity, momentum and energy
conservation equations in addition to standard k – ε model equations
for turbulence closure.
Throughout the investigations, numerical validation is carried out by
way of comparisons of numerical and experimental results. Good
agreement is found among both predictions.