Abstract: Continuous measurements and multivariate methods are applied in researching the effects of energy consumption on indoor air quality (IAQ) in a Finnish one-family house. Measured data used in this study was collected continuously in a house in Kuopio, Eastern Finland, during fourteen months long period. Consumption parameters measured were the consumptions of district heat, electricity and water. Indoor parameters gathered were temperature, relative humidity (RH), the concentrations of carbon dioxide (CO2) and carbon monoxide (CO) and differential air pressure. In this study, self-organizing map (SOM) and Sammon's mapping were applied to resolve the effects of energy consumption on indoor air quality. Namely, the SOM was qualified as a suitable method having a property to summarize the multivariable dependencies into easily observable two-dimensional map. Accompanying that, the Sammon's mapping method was used to cluster pre-processed data to find similarities of the variables, expressing distances and groups in the data. The methods used were able to distinguish 7 different clusters characterizing indoor air quality and energy efficiency in the study house. The results indicate, that the cost implications in euros of heating and electricity energy vary according to the differential pressure, concentration of carbon dioxide, temperature and season.
Abstract: The use of neural networks is popular in various
building applications such as prediction of heating load, ventilation
rate and indoor temperature. Significant is, that only few papers deal
with indoor carbon dioxide (CO2) prediction which is a very good
indicator of indoor air quality (IAQ). In this study, a data-driven
modelling method based on multilayer perceptron network for indoor
air carbon dioxide in an apartment building is developed.
Temperature and humidity measurements are used as input variables
to the network. Motivation for this study derives from the following
issues. First, measuring carbon dioxide is expensive and sensors
power consumptions is high and secondly, this leads to short
operating times of battery-powered sensors. The results show that
predicting CO2 concentration based on relative humidity and
temperature measurements, is difficult. Therefore, more additional
information is needed.
Abstract: In this paper is reported an analysis about the outdoor air pollution of the urban centre of the city of Messina. The variations of the most critical pollutants concentrations (PM10, O3, CO, C6H6) and their trends respect of climatic parameters and vehicular traffic have been studied. Linear regressions have been effectuated for representing the relations among the pollutants; the differences between pollutants concentrations on weekend/weekday were also analyzed. In order to evaluate air pollution and its effects on human health, a method for calculating a pollution index was implemented and applied in the urban centre of the city. This index is based on the weighted mean of the most detrimental air pollutants concentrations respect of their limit values for protection of human health. The analyzed data of the polluting substances were collected by the Assessorship of the Environment of the Regional Province of Messina in the year 2004. A statistical analysis of the air quality index trends is also reported.
Abstract: This study applied the Gaussian trajectory
transfer-coefficient model (GTx) to simulate the particulate matter
concentrations and the source apportionments at Nanzih Air Quality
Monitoring Station in southern Taiwan from November 2007 to
February 2008. The correlation coefficient between the observed and
the calculated daily PM10 concentrations is 0.5 and the absolute bias of
the PM10 concentrations is 24%. The simulated PM10 concentrations
matched well with the observed data. Although the emission rate of
PM10 was dominated by area sources (58%), the results of source
apportionments indicated that the primary sources for PM10 at Nanzih
Station were point sources (42%), area sources (20%) and then upwind
boundary concentration (14%). The obvious difference of PM10 source
apportionment between episode and non-episode days was upwind
boundary concentrations which contributed to 20% and 11% PM10
sources, respectively. The gas-particle conversion of secondary
aerosol and long range transport played crucial roles on the PM10
contribution to a receptor.
Abstract: Particulate matter (PM) in ambient air is responsible
for adverse health effects in adults and children. Relatively little is
known about the concentrations, sources and health effects of PM in
indoor air. A monitoring study was conducted in Ankara by three
campaigns in order to measure PM levels in indoor and outdoor
environments to identify and quantify associations between sources
and concentrations. Approximately 82 homes (1st campaign for 42,
2nd campaign for 12, and 3rd campaign for 28), three rooms (living
room, baby-s room and living room used as a baby-s room) and
outdoor ambient at each home were sampled with Grimm
Environmental Dust Monitoring (EDM) 107, during different
seasonal periods of 2011 and 2012. In this study, the relationship
between indoor and outdoor PM levels for particulate matter less than
10 micrometer (.m) (PM10), particulate matter less than 2.5.m
(PM2.5) and particulate matter less than 1.0.m (PM1) were
investigated. The mean concentration of PM10, PM2.5, and PM1.0 at
living room used as baby-s room is higher than living and baby-s
room (or bedroom) for three sampling campaigns. It is concluded that
the household activities and environmental conditions are very
important for PM concentrations in the indoor environments during
the sampling periods. The amount of smokers, being near a main
street and/or construction activities increased the PM concentration.
This study is based on the assessment the relationship between indoor
and outdoor PM levels and the household activities and
environmental conditions
Abstract: Ventilation is a fundamental requirement for
occupant health and indoor air quality in buildings. Natural
ventilation can be used as a design strategy in free-running
buildings to:
• Renew indoor air with fresh outside air and lower room
temperatures at times when the outdoor air is cooler.
• Promote air flow to cool down the building structure
(structural cooling).
• Promote occupant physiological cooling processes
(comfort cooling).
This paper focuses on ways in which ventilation can
provide the mechanism for heat dissipation and cooling of the
building structure..It also discusses use of ventilation as a
means of increasing air movement to improve comfort when
indoor air temperatures are too high. The main influencing
factors and design considerations and quantitative guidelines
to help meet the design objectives are also discussed.
Abstract: Air quality in Setapak district of Kuala Lumpur was
studied by analysing the rainwater chemical composition using ion
chromatography method. Twelve sampling sites were selected and
120 rainwater samples were collected in the period of 10 weeks. The
results of this study were compared to the earlier published data and
the evaluation showed that the NO3
- ion concentration increased from
0.41 to 3.32 ppm, while SO4
2- ion concentration increased from 0.39
to 3.26 ppm over the past two decades that is mostly due to rapid
urban development of the city. However, it was found that the
chemical composition for both residential and industrial areas does
not have significant difference. Most of the rainwater samples
showed alkaline pH (pH > 5.6). The possible factors for such alkaline
pH in rainwater samples are assumed to be the marine sources,
biomass burning and alkaline character of soil particles.
Abstract: The building sector is the largest energy consumer and
CO2 emitter in the European Union (EU) and therefore the active
reduction of energy consumption and elimination of energy wastage
are among the main goals in it. Healthy housing and energy
efficiency are affected by many factors which set challenges to
monitoring, control and research of indoor air quality (IAQ) and
energy consumption, especially in old buildings. These challenges
include measurement and equipment costs, for example.
Additionally, the measurement results are difficult to interpret and
their usage in the ventilation control is also limited when taking into
account the energy efficiency of housing at the same time. The main
goal of this study is to develop a cost-effective building monitoring
and control system especially for old buildings. The starting point or
keyword of the development process is a wireless system; otherwise
the installation costs become too high. As the main result, this paper
describes an idea of a wireless building monitoring and control
system. The first prototype of the system has been installed in 10
residential buildings and in 10 school buildings located in the City of
Kuopio, Finland.
Abstract: This research aimed to develop plasma system used in air conditioners. This developed plasma system could be installed in the air conditioners - all split type. The quality of air could be improved to be equal to present plasma system. Development processes were as follows: 1) to study the plasma system used in the air conditioners, 2) to design a plasma generator, 3) to develop the plasma generator, and 4) to test its performance in many types of the air conditioners. This plasma system was developed by AC high voltage – 14 kv with a frequency of 50 kHz. Carbon was a conductor to generate arc in air purifier system. The research was tested by installing the plasma generator in the air conditioners - wall type. Whereas, there were 3 types of installations: air flow out, air flow in, and room center. The result of the plasma generator installed in the air conditioners, split type, revealed that the air flow out installation provided the highest average of o-zone at 223 mg/h. This type of installation provided the highest efficiency of air quality improvement. Moreover, the air flow in installation and the room center installation provided the average of the o-zone at 163 mg/h and 64 mg/h, respectively.
Abstract: The present paper was concerned primarily with the
analysis, simulation of the air flow and thermal patterns in a lecture
room. The paper is devoted to numerically investigate the influence
of location and number of ventilation and air conditioning supply and
extracts openings on air flow properties in a lecture room. The work
focuses on air flow patterns, thermal behaviour in lecture room where
large number of students. The effectiveness of an air flow system is
commonly assessed by the successful removal of sensible and latent
loads from occupants with additional of attaining air pollutant at a
prescribed level to attain the human thermal comfort conditions and
to improve the indoor air quality; this is the main target during the
present paper. The study is carried out using computational fluid
dynamics (CFD) simulation techniques as embedded in the
commercially available CFD code (FLUENT 6.2). The CFD
modelling techniques solved the continuity, momentum and energy
conservation equations in addition to standard k – ε model equations
for turbulence closure.
Throughout the investigations, numerical validation is carried out by
way of comparisons of numerical and experimental results. Good
agreement is found among both predictions.
Abstract: The main purpose of this research is the calculation of implicit prices of the environmental level of air quality in the city of Moscow on the basis of housing property prices. The database used contains records of approximately 20 thousand apartments and has been provided by a leading real estate agency operating in Russia. The explanatory variables include physical characteristics of the houses, environmental (industry emissions), neighbourhood sociodemographic and geographic data: GPS coordinates of each house. The hedonic regression results for ecological variables show «negative» prices while increasing the level of air contamination from such substances as carbon monoxide, nitrogen dioxide, sulphur dioxide, and particles (CO, NO2, SO2, TSP). The marginal willingness to pay for higher environmental quality is presented for linear and log-log models.
Abstract: The increased use of biodiesel implies variations on both greenhouse gases and air pollutant emissions. Some studies point out that the use of biodiesel blends on diesel can help in controlling air pollution and promote a reduction of CO2 emissions. Reductions on PM, SO2, VOC and CO emissions are also expected, however NOx emissions may increase, which may potentiate O3 formation. This work aims to assess the impact of the biodiesel use on air quality, through a numerical modeling study, taking the Northern region of Portugal as a case study. The emission scenarios are focused on 2008 (baseline year) and 2020 (target year of Renewable Energy Directive-RED) and on three biodiesel blends (B0, B10 and B20). In a general way the use of biodiesel by 2020 will reduce the CO2 and air pollutants emissions in the Northern Portugal, improving air quality. However it will be in a very small extension.
Abstract: Abstract–Indoor air (VOCs) samples were collected
simultaneously from variety of indoors (e.g. living rooms, baby-s
rooms) and outdoor environments which were voluntarily selected
from the houses in which pregnant residents live throughout Ankara.
This is the first comprehensive study done in Turkey starting from
prenatal period and continued till the babies had one year old. VOCs
levels were measured over 76 homes. Air samples were collected in
Tenax TA sorbent filled tubes with active sampling method and
analyzed with Thermal Desorber and Gas Chromatography/Mass
spectrometry (TD-GC/MS). At the first sampling period in the baby-s
rooms maximum concentration of toluene was measured about
240.77μg.m-3 and in the living rooms maximum concentration of
naphthalene was 180.24μg.m-3. At the second sampling period in the
baby-s rooms maximum concentration of toluene was measured
about 144.97μg.m-3 and in the living rooms maximum concentration
of naphthalene was 247.89μg.m-3. Concentration of TVOCs in the
first period was generally higher than the second period.
Abstract: A good green building design project, designers should consider not only energy consumption, but also healthy and comfortable needs of inhabitants. In recent years, the Taiwan government paid attentions on both carbon reduction and indoor air quality issues, which be presented in the legislation of Building Codes and other regulations. Taiwan located in hot and humid climates, dampness in buildings leads to significant microbial pollution and building damage. This means that the high temperature and humidity present a serious indoor air quality issue. The interactions between vapor transfers and energy fluxes are essential for the whole building Heat Air and Moisture (HAM) response. However, a simulation tool with short calculation time, property accuracy and interface is needed for practical building design processes. In this research, we consider the vapor transfer phenomenon of building materials as well as temperature and humidity and energy consumption in a building space. The simulation bases on the EMPD method, which was performed by EnergyPlus, a simulation tool developed by DOE, to simulate the indoor moisture variation in a one-zone residential unit based on the Effective Moisture Penetration Depth Method, which is more suitable for practical building design processes.
Abstract: The Bangalore City is facing the acute problem of
pollution in the atmosphere due to the heavy increase in the traffic
and developmental activities in recent years. The present study is an
attempt in the direction to assess trend of the ambient air quality
status of three stations, viz., AMCO Batteries Factory, Mysore Road,
GRAPHITE INDIA FACTORY, KHB Industrial Area, Whitefield
and Ananda Rao Circle, Gandhinagar with respect to some of the
major criteria pollutants such as Total Suspended particular matter
(SPM), Oxides of nitrogen (NOx), and Oxides of sulphur (SO2). The
sites are representative of various kinds of growths viz., commercial,
residential and industrial, prevailing in Bangalore, which are
contributing to air pollution. The concentration of Sulphur Dioxide
(SO2) at all locations showed a falling trend due to use of refined
petrol and diesel in the recent years. The concentration of Oxides of
nitrogen (NOx) showed an increasing trend but was within the
permissible limits. The concentration of the Suspended particular
matter (SPM) showed the mixed trend. The correlation between
model and observed values is found to vary from 0.4 to 0.7 for SO2,
0.45 to 0.65 for NOx and 0.4 to 0.6 for SPM. About 80% of data is
observed to fall within the error band of ±50%. Forecast test for the
best fit models showed the same trend as actual values in most of the
cases. However, the deviation observed in few cases could be
attributed to change in quality of petro products, increase in the
volume of traffic, introduction of LPG as fuel in many types of
automobiles, poor condition of roads, prevailing meteorological
conditions, etc.
Abstract: This paper presents the development of analysis tools
for Home Agriculture project. The tools are required for monitoring
the condition of greenhouse which involves two components:
measurement hardware and data analysis engine. Measurement
hardware is functioned to measure environment parameters such as
temperature, humidity, air quality, dust and etc while analysis tool is
used to analyse and interpret the integrated data against the condition
of weather, quality of health, irradiance, quality of soil and etc. The
current development of the tools is completed for off-line data
recorded technique. The data is saved in MMC and transferred via
ZigBee to Environment Data Manager (EDM) for data analysis.
EDM converts the raw data and plot three combination graphs. It has
been applied in monitoring three months data measurement for
irradiance, temperature and humidity of the greenhouse..
Abstract: This paper describes studies carried out to investigate
the viability of using wireless cameras as a tool in monitoring
changes in air quality. A camera is used to monitor the change in
colour of a chemically responsive polymer within view of the camera
as it is exposed to varying chemical species concentration levels. The
camera captures this image and the colour change is analyzed by
averaging the RGB values present. This novel chemical sensing
approach is compared with an established chemical sensing method
using the same chemically responsive polymer coated onto LEDs. In
this way, the concentration levels of acetic acid in the air can be
tracked using both approaches. These approaches to chemical plume
tracking have many applications for air quality monitoring.
Abstract: Clean air in subway station is important to passengers. The Platform Screen Doors (PSDs) can improve indoor air quality in the subway station; however the air quality in the subway tunnel is degraded. The subway tunnel has high CO2 concentration and indoor particulate matter (PM) value. The Indoor Air Quality (IAQ) level in subway environment degrades by increasing the frequency of the train operation and the number of the train. The ventilation systems of the subway tunnel need improvements to have better air-quality. Numerical analyses might be effective tools to analyze the performance of subway twin-track tunnel ventilation systems. An existing subway twin-track tunnel in the metropolitan Seoul subway system is chosen for the numerical simulations. The ANSYS CFX software is used for unsteady computations of the airflow inside the twin-track tunnel when the train moves. The airflow inside the tunnel is simulated when one train runs and two trains run at the same time in the tunnel. The piston-effect inside the tunnel is analyzed when all shafts function as the natural ventilation shaft. The supplied air through the shafts is mixed with the pollutant air in the tunnel. The pollutant air is exhausted by the mechanical ventilation shafts. The supplied and discharged airs are balanced when only one train runs in the twin-track tunnel. The pollutant air in the tunnel is high when two trains run simultaneously in opposite direction and all shafts functioned as the natural shaft cases when there are no electrical power supplies in the shafts. The remained pollutant air inside the tunnel enters into the station platform when the doors are opened.
Abstract: The Platform Screen Doors improve Indoor Air Quality
(IAQ) in the subway station; however, and the air quality is degraded
in the subway tunnel. CO2 concentration and indoor particulate matter
value are high in the tunnel. The IAQ level in subway tunnel degrades
by increasing the train movements. Air-curtain installation reduces
dusts, particles and moving toxic smokes and permits traffic by
generating virtual wall. The ventilation systems of the subway tunnel
need improvements to have better air-quality. Numerical analyses
might be effective tools analyze the flowfield inside the air-curtain
installed subway tunnel. The ANSYS CFX software is used for steady
computations of the airflow inside the tunnel. The single-track subway
tunnel has the natural shaft, the mechanical shaft, and the PSDs
installed stations. The height and width of the tunnel are 6.0 m and 4.0
m respectively. The tunnel is 400 m long and the air-curtain is installed
at the top of the tunnel. The thickness and the width of the air-curtain
are 0.08 m and 4 m respectively. The velocity of the air-curtain
changes between 20 - 30 m/s. Three cases are analyzed depending on
the installing location of the air-curtain. The discharged-air through
the natural shafts increases as the velocity of the air-curtain increases
when the air-curtain is installed between the mechanical and the
natural shafts. The pollutant-air is exhausted by the mechanical and the
natural shafts and remained air is pushed toward tunnel end. The
discharged-air through the natural shaft is low when the air-curtain
installed before the natural shaft. The mass flow rate decreases in the
tunnel after the mechanical shaft as the air-curtain velocity increases.
The computational results of the air-curtain installed tunnel become
basis for the optimum design study. The air-curtain installing location
is chosen between the mechanical and the natural shafts. The velocity
of the air-curtain is fixed as 25 m/s. The thickness and the blowing
angles of the air-curtain are the design variables for the optimum
design study. The object function of the design optimization is
maximizing the discharged air through the natural shaft.
Abstract: Air quality studies were carried out in the towns of
Putrajaya, Petaling Jaya and Nilai in the Malaysian Peninsular. In this
study, the variations of Ozone (O3) concentrations over a four year
period (2008-2011) were investigated using data obtained from the
Malaysian Department of the Environment (DOE). This study aims to
identify and describe the daily and monthly variations of O3
concentrations at the monitoring sites mentioned. The SPPS program
(Statistical Package for the Social Science) was used to analyze this
data in order to obtain the variations of O3 and also to clarify the
relationship between the stations. The findings of the study revealed
that the highest concentration of O3 occurred during the midday and
afternoon (between 13:00-15:00 hrs). The comparison between
stations also showed that highest O3 concentrations were recorded in
Putrajaya. The comparisons of average and maximum concentrations
of O3 for the three stations showed that the strongest significant
correlation was recorded in the Petaling Jaya station with the value
R2= 0.667. Results from this study indicate that in the urban areas of
Peninsular Malaysia, the concentration of O3 depends on the
concentration of NOx. Furthermore, HYSPLIT back trajectories
(-72h) indicated that air-mass transport patterns can also influence the
O3 concentration in the areas studied.