Abstract: Air conditioning is mainly use as human comfort
cooling medium. It use more in high temperatures are country such as
Malaysia. Proper estimation of cooling load will archive ideal
temperature. Without proper estimation can lead to over estimation or
under estimation. The ideal temperature should be comfort enough.
This study is to develop a program to calculate an ideal cooling load
demand, which is match with heat gain. Through this study, it is easy
to calculate cooling load estimation. Objective of this study are to
develop user-friendly and easy excess cooling load program. This is
to insure the cooling load can be estimate by any of the individual
rather than them using rule-of-thumb. Developed software is carryout
by using Matlab-GUI. These developments are only valid for
common building in Malaysia only. An office building was select as
case study to verify the applicable and accuracy of develop software.
In conclusion, the main objective has successfully where developed
software is user friendly and easily to estimate cooling load demand.
Abstract: Supercritical carbon dioxide (SC-CO2) was used as a
solvent to extract oil from wheat bran. Extractions were carried out in a
semi-batch process at temperatures ranging from 40 to 60ºC and
pressures ranging from 10 to 30 MPa, with a carbon dioxide (CO2)
flow rate of 26.81 g/min. The oil obtained from wheat bran at different
extraction conditions was quantitatively measured to investigate the
solubility of oil in SC-CO2. The solubility of wheat bran oil was found
to be enhanced in high temperature and pressure. The composition of
fatty acids in wheat bran oil was measured by gas chromatography
(GC). Linoleic, palmitic, oleic and γ-linolenic acid were the major
fatty acids of wheat bran oil. Tocopherol contents in oil were analyzed
by high performance liquid chromatography (HPLC). The highest
amount of phenolics and tocopherols (α and β) were found at
temperature of 60ºC and pressure of 30 MPa.
Abstract: The high temperature degree and uniform
Temperature Distribution (TD) on surface of cookware which contact
with food are effective factors for improving cookware application.
Additionally, the ability of pan material in retaining the heat and nonreactivity
with foods are other significant properties. It is difficult for
single material to meet a wide variety of demands such as superior
thermal and chemical properties. Multi-Layer Plate (MLP) makes
more regular TD. In this study the main objectives are to find the best
structure (single or multi-layer) and materials to provide maximum
temperature degree and uniform TD up side surface of pan. And also
heat retaining of used metals with goal of improving the thermal
quality of pan to economize the energy. To achieve this aim were
employed Finite Element Method (FEM) for analyzing transient
thermal behavior of applied materials. The analysis has been
extended for different metals, we achieved the best temperature
profile and heat retaining in Copper/ Stainless Steel MLP.
Abstract: High strength concrete has been used in situations
where it may be exposed to elevated temperatures. Numerous authors
have shown the significant contribution of polypropylene fiber to the
spalling resistance of high strength concrete.
When cement-based composite that reinforced by polypropylene
fibers heated up to 170 °C, polypropylene fibers readily melt and
volatilize, creating additional porosity and small channels in to the
matrix that cause the poor structure and low strength.
This investigation develops on the mechanical properties of mortar
incorporating polypropylene fibers exposed to high temperature.
Also effects of different pozzolans on strength behaviour of samples
at elevated temperature have been studied.
To reach this purpose, the specimens were produced by partial
replacement of cement with finely ground glass, silica fume and rice
husk ash as high reactive pozzolans. The amount of this replacement
was 10% by weight of cement to find the effects of pozzolans as a
partial replacement of cement on the mechanical properties of
mortars. In this way, lots of mixtures with 0%, 0.5%, 1% and 1.5% of
polypropylene fibers were cast and tested for compressive and
flexural strength, accordance to ASTM standard. After that
specimens being heated to temperatures of 300, 600 °C, respectively,
the mechanical properties of heated samples were tested.
Mechanical tests showed significant reduction in compressive
strength which could be due to polypropylene fiber melting. Also
pozzolans improve the mechanical properties of sampels.
Abstract: This paper presents the comparison ageing deterioration of silicone rubber housing material for outdoor polymer insulators by using salt fog ageing test based on IEC 61109 and outdoor exposure test.Four types of high temperature silicone vulcanized silicone rubber sheet with different amount of ATH were used as testing specimen. For salt fog ageing test, the specimens were tested continuously 1000 hours with energized in test chamber. For outdoor exposure test, the specimens were hung continuously 18 months without energized. Physical and chemical analyses were conducted to evaluate degree of ageing deterioration of tested specimens. Slightly surface erosion was observed on specimen surface after salt fog ageing test and no erosion was observed on surface of outdoor exposure specimen. However, comparable degree of ageing deterioration can be seen from surface analysis results.
Abstract: The precision of heat flux simulation influences the
temperature field and test aberration for TB test and also reflects the
test level for spacecraft development. This paper describes TB tests for
a small satellite using solar simulator, electric heaters, calrod heaters
to evaluate the difference of the three methods. Under the same
boundary condition, calrod heaters cases were about 6oC higher than
solar simulator cases and electric heaters cases for
non-external-heat-flux cases (extreme low temperature cases). While
calrod heaters cases and electric heaters cases were 5~7oC and 2~3oC
lower than solar simulator cases respectively for high temperature
cases. The results show that the solar simulator is better than calrod
heaters for its better collimation, non-homogeneity and stability.