Abstract: The crystallization kinetics and phase transformation
of SiO2.Al2O3.0,56P2O5.1,8CaO.0,56CaF2 glass have been
investigated using differential thermal analysis (DTA), x-ray
diffraction (XRD), and scanning electron microscopy (SEM). Glass
samples were obtained by melting the glass mixture at 14500С/120
min. in platinum crucibles. The mixture were prepared from
chemically pure reagents: SiO2, Al(OH)3, H3PO4, CaCO3 and CaF2.
The non-isothermal kinetics of crystallization was studied by
applying the DTA measurements carried out at various heating rates.
The activation energies of crystallization and viscous flow were
measured as 348,4 kJ.mol–1 and 479,7 kJ.mol–1 respectively. Value of
Avrami parameter n ≈ 3 correspond to a three dimensional of crystal
growth mechanism. The major crystalline phase determined by XRD
analysis was fluorapatite (Ca(PO4)3F) and as the minor phases –
fluormargarite (CaAl2(Al2SiO2)10F2) and vitlokite (Ca9P6O24). The
resulting glass-ceramic has a homogeneous microstructure, composed
of prismatic crystals, evenly distributed in glass phase.
Abstract: Combined experimental and computational analysis of
hygrothermal performance of an interior thermal insulation system
applied on a brick wall is presented in the paper. In the experimental
part, the functionality of the insulation system is tested at simulated
difference climate conditions using a semi-scale device. The
measured temperature and relative humidity profiles are used for the
calibration of computer code HEMOT that is finally applied for a
long-term hygrothermal analysis of the investigated structure.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetically and thermal stresses remain major failures
for insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: In this paper a three dimensional thermal model of
high breaking capacity fuse with unequal fuse links is proposed for
both steady-state or transient conditions. The influence of ambient
temperature and electric current on the temperature distribution
inside the fuse, has been investigated. A thermal analysis of the
unbalanced distribution of the electric current through the fuse
elements and their influence on fuse link temperature rise, has been
performed. To validate the three dimensional thermal model, some
experimental tests have been done. There is a good correlation
between experimental and simulation results.
Abstract: Optimal selection of electrical insulations in electrical
machinery insures reliability during operation. From the insulation
studies of view for electrical machines, stator is the most important
part. This fact reveals the requirement for inspection of the electrical
machine insulation along with the electro-thermal stresses. In the
first step of the study, a part of the whole structure of machine in
which covers the general characteristics of the machine is chosen,
then based on the electromagnetic analysis (finite element method),
the machine operation is simulated. In the simulation results, the
temperature distribution of the total structure is presented
simultaneously by using electro-thermal analysis. The results of
electro-thermal analysis can be used for designing an optimal cooling
system. In order to design, review and comparing the cooling
systems, four wiring structures in the slots of Stator are presented.
The structures are compared to each other in terms of electrical,
thermal distribution and remaining life of insulation by using Finite
Element analysis. According to the steps of the study, an optimization
algorithm has been presented for selection of appropriate structure.
Abstract: The paper presents coupled electromagnetic and
thermal field analysis of busbar system (of rectangular cross-section
geometry) submitted to short circuit conditions. The laboratory model
was validated against both analytical solution and experimental
observations. The considered problem required the computation of
the detailed distribution of the power losses and the heat transfer
modes. In this electromagnetic and thermal analysis, different
definitions of electric busbar heating were considered and compared.
The busbar system is a three phase one and consists of aluminum,
painted aluminum and copper busbar. The solution to the coupled
field problem is obtained using the finite element method and the
QuickField™ program. Experiments have been carried out using two
different approaches and compared with computed results.
Abstract: A piston cylinder based high pressure differential
thermal analyzer system is developed to investigate phase
transformations, melting, glass transitions, crystallization behavior of
inorganic materials, glassy systems etc., at ambient to 4 GPa and at
room temperature to 1073 K. The pressure is calibrated by the phase
transition of bismuth and ytterbium and temperature is calibrated
by using thermocouple data chart. The system developed is
calibrated using benzoic acid, ammonium nitrate and it has a
pressure and temperature control of ± 8.9 x 10 -4 GPa , ± 2 K
respectively. The phase transition of Asx Te100-x chalcogenides,
ferrous oxide and strontium boride are studied using the
indigenously developed system.
Abstract: This paper presents the results of a study aimed at
establishing the temperature distribution during the welding of
magnesium alloy sheets by Pulsed Current Gas Tungsten Arc
Welding (PCGTAW) and Constant Current Gas Tungsten Arc
Welding (CCGTAW) processes. Pulsing of the GTAW welding
current influences the dimensions and solidification rate of the fused
zone, it also reduces the weld pool volume hence a narrower bead. In
this investigation, the base material considered was 2mm thin AZ 31
B magnesium alloy, which is finding use in aircraft, automobile and
high-speed train components. A finite element analysis was carried
out using ANSYS, and the results of the FEA were compared with
the experimental results. It is evident from this study that the finite
element analysis using ANSYS can be effectively used to model
PCGTAW process for finding temperature distribution.