Abstract: In order to apply partially filled steel grid composite deck as the horizontal supporting structure of various kinds of infrastructures, the variation of its flexural strength according to design parameters such as cross and longitudinal bars constituting the steel grid and the type of shear connection is evaluated and compared experimentally. The result shows that the design sensitivity of the deck to the spacing of the cross bars is insignificant in the case of structure with low risk of punching failure or without load distribution problem. By means of shear connection composed by transverse rebar and longitudinal bar without additional shear stud bolts, the complete interaction between steel grid and concrete slab is able to be achieved and the composite deck can develop its bending resistance capacity.
Abstract: The Indian subcontinent is facing a massive challenge with regards to the energy security in member countries, i.e. providing a reliable source of electricity to facilitate development across various sectors of the economy and thereby achieve the developmental targets it has set for itself. A highly precarious situation exists in the subcontinent which is observed in the series of system failures which most of the times leads to system collapses-blackouts. To mitigate the issues related with energy security as well as keep in check the increasing supply demand gap, a possible solution that stands in front of the subcontinent is the deployment of an interconnected electricity ‘Supergrid’ designed to carry huge quanta of power across the sub continent as well as provide the infra structure for RES integration. This paper assesses the need and conditions for a Supergrid deployment and consequently proposes a meshed topology based on VSC HVDC converters for the Supergrid modeling.
Abstract: Pressure waves and Water Hammer occur in a
pumping system when valves are closed or opened suddenly or in
the case of sudden failure of pumps. Determination of maximum
water hammer is considered one of the most important technical
and economical items of which engineers and designers of
pumping stations and conveyance pipelines should take care.
Hammer Software is a recent application used to simulate water
hammer. The present study focuses on determining significance of
each input parameter of the application relative to the maximum
amount of water hammer estimated by the software. The study
determines estimated maximum water hammer variations due to
variations of input parameters including water temperature, pipe
type, thickness and diameter, electromotor rpm and power, and
moment of inertia of electromotor and pump. In our study,
Kuhrang Pumping Station was modeled using WaterGEMS
Software. The pumping station is characterized by total discharge
of 200 liters per second, dynamic height of 194 meters and 1.5
kilometers of steel conveyance pipeline and transports water to
Cheshme Morvarid for farmland irrigation. The model was run in
steady hydraulic condition and transferred to Hammer Software.
Then, the model was run in several unsteady hydraulic conditions
and sensitivity of maximum water hammer to each input parameter
was calculated. It is shown that parameters to which maximum
water hammer is most sensitive are moment of inertia of pump and
electromotor, diameter, type and thickness of pipe and water
temperature, respectively.
Abstract: This paper proposes a Wavelength Division
Multiplexing (WDM) technology based Storage Area Network
(SAN) for all type of Disaster recovery operation. It considers
recovery when all paths failure in the network as well as the main
SAN site failure also the all backup sites failure by the effect of
natural disasters such as earthquakes, fires and floods, power outage,
and terrorist attacks, as initially SAN were designed to work within
distance limited environments[2]. Paper also presents a NEW PATH
algorithm when path failure occurs. The simulation result and
analysis is presented for the proposed architecture with performance
consideration.
Abstract: This paper shows the advantages of the material failure process simulation by improve finite elements with embedded discontinuities, using a new definition of traction vector, dependent on the discontinuity length and the angle. Particularly, two families of this kind of elements are compared: kinematically optimal symmetric and statically and kinematically optimal non-symmetric. The constitutive model to describe the behavior of the material in the symmetric formulation is a traction-displacement jump relationship equipped with softening after reaching the failure surface.
To show the validity of this symmetric formulation, representative numerical examples illustrating the performance of the proposed formulation are presented. It is shown that the non-symmetric family may over or underestimate the energy required to create a discontinuity, as this effect is related with the total length of the discontinuity, fact that is not noticed when the discontinuity path is a straight line.
Abstract: Oxide scale thickness measurements are used in assessing the life of different components operating at high temperature environment. Such measurements provide an approximation for the temperature inside components such as reheater and superheater tubes. A number of failures were encountered in one of the boilers in one of Kuwaiti power plants. These failure were mainly in the first row of the primary super heater tubes, therefore, the specialized engineer decide to replace them during the annual shutdown. As a tool for failure analysis, oxide scale thickness measurement were used to investigate the temperature distribution in these tubes. In this paper, the oxide scale thickness of these tubes were measured and used for analysis. The measurements provide an illustration of the distribution of heat transfer of the primary superheater tubes in the boiler system. Remarks and analysis about the design of the boiler are also provided.
Abstract: Personnel protection devices are cardinal in safety hazard applications. They are widely used in home, office and in industry environments to reduce the risk of lethal shock to human being and equipment safety. This paper briefly reviews various personnel protection devices also describes the basic working principle of conventional ground fault circuit interrupter (GFCI) or ground fault isolator (GFI), its disadvantages and ways to overcome the disadvantages with solid-state relay (SSR) based GFI with ultrafast response up on fault implemented in printed circuit board. This solid state GFI comprises discrete MOSFET based alternating current (AC) switches, linear optical amplifier, photovoltaic isolator and sense resistor. In conventional GFI, current transformer is employed as a sensing element to detect the difference in current flow between live and neutral conductor. If there is no fault in equipment powered through GFI, due to insulation failure of internal wires and windings of motors, both live and neutral currents will be equal in magnitude and opposite in phase.
Abstract: Insulation used in transformer is mostly oil pressboard insulation. Insulation failure is one of the major causes of catastrophic failure of transformers. It is established that partial discharges (PD) cause insulation degradation and premature failure of insulation. Online monitoring of PDs can reduce the risk of catastrophic failure of transformers. There are different techniques of partial discharge measurement like, electrical, optical, acoustic, opto-acoustic and ultra high frequency (UHF). Being non invasive and non interference prone, acoustic emission technique is advantageous for online PD measurement. Acoustic detection of p.d. is based on the retrieval and analysis of mechanical or pressure signals produced by partial discharges. Partial discharges are classified according to the origin of discharges. Their effects on insulation deterioration are different for different types. This paper reports experimental results and analysis for classification of partial discharges using acoustic emission signal of laboratory simulated partial discharges in oil pressboard insulation system using three different electrode systems. Acoustic emission signal produced by PD are detected by sensors mounted on the experimental tank surface, stored on an oscilloscope and fed to computer for further analysis. The measured AE signals are analyzed using discrete wavelet transform analysis and wavelet packet analysis. Energy distribution in different frequency bands of discrete wavelet decomposed signal and wavelet packet decomposed signal is calculated. These analyses show a distinct feature useful for PD classification. Wavelet packet analysis can sort out any misclassification arising out of DWT in most cases.
Abstract: management of medical devices in hospitals includes
the planning of medical equipment acquisition and maintenance. The
presence of critical and non-critical areas together with technological
proliferation render the management of medical devices very
complex. This study creates an easy and objective methodology for
the analysis of medical equipment maintenance, that makes the
management of medical devices more feasible. The study has been
carried out at Florence Hospital Careggi and it aims to help the
clinical engineering department to manage medical equipment by
clarifying the hospital situation through a characterization of the
different areas, technologies and fault typologies.
Abstract: This paper deals with condition monitoring of electric switch machine for railway points. Point machine, as a complex electro-mechanical device, switch the track between two alternative routes. There has been an increasing interest in railway safety and the optimal management of railway equipments maintenance, e.g. point machine, in order to enhance railway service quality and reduce system failure. This paper explores the development of Kolmogorov- Smirnov (K-S) test to detect some point failures (external to the machine, slide chairs, fixing, stretchers, etc), while the point machine (inside the machine) is in its proper condition. Time-domain stator Current signatures of normal (healthy) and faulty points are taken by 3 Hall Effect sensors and are analyzed by K-S test. The test is simulated by creating three types of such failures, namely putting a hard stone and a soft stone between stock rail and switch blades as obstacles and also slide chairs- friction. The test has been applied for those three faults which the results show that K-S test can effectively be developed for the aim of other point failures detection, which their current signatures deviate parametrically from the healthy current signature. K-S test as an analysis technique, assuming that any defect has a specific probability distribution. Empirical cumulative distribution functions (ECDF) are used to differentiate these probability distributions. This test works based on the null hypothesis that ECDF of target distribution is statistically similar to ECDF of reference distribution. Therefore by comparing a given current signature (as target signal) from unknown switch state to a number of template signatures (as reference signal) from known switch states, it is possible to identify which is the most likely state of the point machine under analysis.
Abstract: In the present paper the results of a numerical study are presented, numerical models were developed to simulate the behaviour of vertical massive dikes. The proposed models were developed according to the geometry, boundary conditions, loading conditions and initial conditions of a physical model taken as reference. The results obtained were compared to the experimental data. As far as the overall behaviour, the displacements and the failure mechanisms of the dikes is concerned, the numerical results were in good agreement with the experimental results, which clearly indicates a good quality of numerical modelling. The validated numerical models were used in a parametric study were the displacements and failure mechanisms were fully investigated. Out of the results obtained, some conclusions and recommendations related to the design of massive dikes are proposed.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetical and thermal stresses remain major failures for
insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: The concept of e-government has begun to spread among countries. It is based on the use of information communication technology (ICT) to fully utilize government resources, as well as to provide government services to citizens, investors and foreigners. Critical factors are the factors that are determined by the senior management of each organization; the success or failure of the organization depends on the effective implementation of critical factors. These factors vary from one organization to another according to their activity, size and functions. It is very important that organizations identify them in order to avoid the risk of implementing initiatives that may fail to work, while simultaneously exploiting opportunities that may succeed in working. The main focus of this paper is to investigate the majority of critical success factors (CSFs) associated with the implementation of e-government projects. This study concentrates on both technical and nontechnical factors. This paper concludes by listing the majority of CSFs relating to successful e-government implementation in Bahrain.
Abstract: The tubes in an Ammonia primary reformer furnace
operate close to the limits of materials technology in terms of the
stress induced as a result of very high temperatures, combined with
large differential pressures across the tube wall. Operation at tube
wall temperatures significantly above design can result in a rapid
increase in the number of tube failures, since tube life is very
sensitive to the absolute operating temperature of the tube. Clearly it
is important to measure tube wall temperatures accurately in order to
prevent premature tube failure by overheating.. In the present study,
the catalyst tubes in an Ammonia primary reformer has been modeled
taking into consideration heat, mass and momentum transfer as well
as reformer characteristics.. The investigations concern the effects of
tube characteristics and superficial tube wall temperatures on of the
percentage of heat flux, unconverted methane and production of
Hydrogen for various values of steam to carbon ratios. The results
show the impact of catalyst tubes length and diameters on the
performance of operating parameters in ammonia primary reformers.
Abstract: A two-parameter fatigue model explicitly accounting for the cyclic as well as the mean stress was used to fit static and fatigue data available in literature concerning carbon fiber reinforced composite laminates subjected tension-tension fatigue. The model confirms the strength–life equal rank assumption and predicts reasonably the probability of failure under cyclic loading. The model parameters were found by best fitting procedures and required a minimum of experimental tests.
Abstract: This paper discusses the approach of real-time
controlling of the energy management system using the data
acquisition tool of LabVIEW. The main idea of this inspiration was
to interface the Station (PC) with the system and publish the data on
internet using LabVIEW. In this venture, controlling and switching of
3 phase AC loads are effectively and efficiently done. The phases are
also sensed through devices. In case of any failure the attached
generator starts functioning automatically. The computer sends
command to the system and system respond to the request. The
modern feature is to access and control the system world-wide using
world wide web (internet). This controlling can be done at any time
from anywhere to effectively use the energy especially in developing
countries where energy management is a big problem. In this system
totally integrated devices are used to operate via remote location.
Abstract: This paper presents a model for an unreliable
production line, which is operated according to demand with constant
work-in-process (CONWIP). A simulation model is developed based
on the discrete model and several case problems are analyzed using
the model. The model is utilized to optimize storage space capacities
at intermediate stages and the number of kanbans at the last stage,
which is used to trigger the production at the first stage. Furthermore,
effects of several line parameters on production rate are analyzed
using design of experiments.
Abstract: Topological changes in mobile ad hoc networks
frequently render routing paths unusable. Such recurrent path failures
have detrimental effects on quality of service. A suitable technique
for eliminating this problem is to use multiple backup paths between
the source and the destination in the network. This paper proposes an
effective and efficient protocol for backup and disjoint path set in ad
hoc wireless network. This protocol converges to a highly reliable
path set very fast with no message exchange overhead. The paths
selection according to this algorithm is beneficial for mobile ad hoc
networks, since it produce a set of backup paths with more high
reliability. Simulation experiments are conducted to evaluate the
performance of our algorithm in terms of route numbers in the path
set and its reliability. In order to acquire link reliability estimates, we
use link expiration time (LET) between two nodes.
Abstract: A first intermediate roll of Sendzirmir mills was failure
by surface spalling during operation. After analyzing by visual, stereo
microscope, optical microscope, scanning electron microscope,
glow-discharged spectrometer and hardness test, respectively, the
results show that some voids and cracks existed on the contact surface
as well as subsurface. Further examination verified inadequate
hardness and inclusions were responsible for the failure of surface
spalling.
Abstract: Locating the critical slip surface with the minimum factor of safety for a rock slope is a difficult problem. In recent years, some modern global optimization methods have been developed with success in treating various types of problems, but very few of such methods have been applied to rock mechanical problems. In this paper, use of hybrid model based on artificial immune system and cellular learning automata is proposed. The results show that the algorithm is an effective and efficient optimization method with a high level of confidence rate.