Abstract: A new topology of unified power quality conditioner
(UPQC) is proposed for different power quality (PQ) improvement in
a three-phase four-wire (3P-4W) distribution system. For neutral
current mitigation, a star-hexagon transformer is connected in shunt
near the load along with three-leg voltage source inverters (VSIs)
based UPQC. For the mitigation of source neutral current, the uses of
passive elements are advantageous over the active compensation due
to ruggedness and less complexity of control. In addition to this, by
connecting a star-hexagon transformer for neutral current mitigation
the over all rating of the UPQC is reduced. The performance of the
proposed topology of 3P-4W UPQC is evaluated for power-factor
correction, load balancing, neutral current mitigation and mitigation
of voltage and currents harmonics. A simple control algorithm based
on Unit Vector Template (UVT) technique is used as a control
strategy of UPQC for mitigation of different PQ problems. In this
control scheme, the current/voltage control is applied over the
fundamental supply currents/voltages instead of fast changing APFs
currents/voltages, thereby reducing the computational delay.
Moreover, no extra control is required for neutral source current
compensation; hence the numbers of current sensors are reduced. The
performance of the proposed topology of UPQC is analyzed through
simulations results using MATLAB software with its Simulink and
Power System Block set toolboxes.
Abstract: Optimization and control of reactive power
distribution in the power systems leads to the better operation of the
reactive power resources. Reactive power control reduces
considerably the power losses and effective loads and improves the
power factor of the power systems. Another important reason of the
reactive power control is improving the voltage profile of the power
system. In this paper, voltage and reactive power control using
Neural Network techniques have been applied to the 33 shines-
Tehran Electric Company. In this suggested ANN, the voltages of PQ
shines have been considered as the input of the ANN. Also, the
generators voltages, tap transformers and shunt compensators have
been considered as the output of ANN. Results of this techniques
have been compared with the Linear Programming. Minimization of
the transmission line power losses has been considered as the
objective function of the linear programming technique. The
comparison of the results of the ANN technique with the LP shows
that the ANN technique improves the precision and reduces the
computation time. ANN technique also has a simple structure and
this causes to use the operator experience.
Abstract: Electricity market activities and a growing demand for electricity have led to heavily stressed power systems. This requires operation of the networks closer to their stability limits. Power system operation is affected by stability related problems, leading to unpredictable system behavior. Voltage stability refers to the ability of a power system to sustain appropriate voltage levels through large and small disturbances. Steady-state voltage stability is concerned with limits on the existence of steady-state operating points for the network. FACTS devices can be utilized to increase the transmission capacity, the stability margin and dynamic behavior or serve to ensure improved power quality. Their main capabilities are reactive power compensation, voltage control and power flow control. Among the FACTS controllers, Static Var Compensator (SVC) provides fast acting dynamic reactive compensation for voltage support during contingency events. In this paper, voltage stability assessment with appropriate representations of tap-changer transformers and SVC is investigated. Integrating both of these devices is the main topic of this paper. Effect of the presence of tap-changing transformers on static VAR compensator controller parameters and ratings necessary to stabilize load voltages at certain values are highlighted. The interrelation between transformer off nominal tap ratios and the SVC controller gains and droop slopes and the SVC rating are found. P-V curves are constructed to calculate loadability margins.
Abstract: In this paper, we propose an advanced ILQ control for the buck-converter via two-degrees of freedom servo-system. Our presented strategy is based on Inverse Linear Quadratic (ILQ) servo-system controller without solving Riccati-s equation directly. The optimal controller of the current and voltage control system is designed. The stability and robust control are analyzed. A conscious and persistent effort has been made to improve ILQ control via two-degrees of freedom guarantees the optimal gains on the basis of polynomial pole assignment, which our results of the proposed strategy shows that the advanced ILQ control can be controlled independently the step response and the disturbance response by appending a feed-forward compensator.
Abstract: In recent years Operational Transconductance Amplifier based high frequency integrated circuits, filters and systems have been widely investigated. The usefulness of OTAs over conventional OP-Amps in the design of both first order and second order active filters are well documented. This paper discusses some of the tunability issues using the Matlab/Simulink® software which are previously unreported for any commercial OTA. Using the simulation results two first order voltage controlled all pass filters with phase tuning capability are proposed.
Abstract: This paper presents the DC voltage control design of D-STATCOM when the D-STATCOM is used for load voltage regulation. Although, the DC voltage can be controlled by active current of the D-STATCOM, reactive current still affects the DC voltage. To eliminate this effect, the control strategy with elimination effect of the reactive current is proposed and the results of the control with and without the elimination the effect of the reactive current are compared. For obtaining the proportional and integral gains of the PI controllers, the symmetrical optimum and genetic algorithms methods are applied. The stability margin of these methods are obtained and discussed in detail. In addition, the performance of the DC voltage control based on symmetrical optimum and genetic algorithms methods are compared. Effectiveness of the controllers designed was verified through computer simulation performed by using Power System Tool Block (PSB) in SIMULINK/MATLAB. The simulation results demonstrated that the DC voltage control proposed is effective in regulating DC voltage when the DSTATCOM is used for load voltage regulation.
Abstract: The steady-state operation of maintaining voltage
stability is done by switching various controllers scattered all over
the power network. When a contingency occurs, whether forced or
unforced, the dispatcher is to alleviate the problem in a minimum
time, cost, and effort. Persistent problem may lead to blackout. The
dispatcher is to have the appropriate switching of controllers in terms
of type, location, and size to remove the contingency and maintain
voltage stability. Wrong switching may worsen the problem and that
may lead to blackout. This work proposed and used a Fuzzy CMeans
Clustering (FCMC) to assist the dispatcher in the decision
making. The FCMC is used in the static voltage stability to map
instantaneously a contingency to a set of controllers where the types,
locations, and amount of switching are induced.
Abstract: In this paper, a new K-means clustering based
approach for identification of voltage control areas is developed.
Voltage control areas are important for efficient reactive power
management in power systems operating under deregulated
environment. Although, voltage control areas are formed using
conventional hierarchical clustering based method, but the present
paper investigate the capability of K-means clustering for the
purpose of forming voltage control areas. The proposed method is
tested and compared for IEEE 14 bus and IEEE 30 bus systems. The
results show that this K-means based method is competing with
conventional hierarchical approach
Abstract: Active Power Filters (APFs) are today the most
widely used systems to eliminate harmonics compensate power
factor and correct unbalanced problems in industrial power plants.
We propose to improve the performances of conventional APFs by
using artificial neural networks (ANNs) for harmonics estimation.
This new method combines both the strategies for extracting the
three-phase reference currents for active power filters and DC link
voltage control method. The ANNs learning capabilities to
adaptively choose the power system parameters for both to compute
the reference currents and to recharge the capacitor value requested
by VDC voltage in order to ensure suitable transit of powers to
supply the inverter. To investigate the performance of this
identification method, the study has been accomplished using
simulation with the MATLAB Simulink Power System Toolbox. The
simulation study results of the new (SAPF) identification technique
compared to other similar methods are found quite satisfactory by
assuring good filtering characteristics and high system stability.
Abstract: In this paper, we propose a novel adaptive voltage control strategy for boost converter via Inverse LQ Servo-Control. Our presented strategy is based on an analytical formula of Inverse Linear Quadratic (ILQ) design method, which is not necessary to solve Riccati’s equation directly. The optimal and adaptive controller of the voltage control system is designed. The stability and the robust control are analyzed. Whereas, we can get the analytical solution for the optimal and robust voltage control is achieved through the natural angular velocity within a single parameter and we can change the responses easily via the ILQ control theory. Our method provides effective results as the stable responses and the response times are not drifted even if the condition is changed widely.
Abstract: This paper aims to give a full study of the dynamic
behavior of a mono-phase active power filter. First, the principle of
the parallel active power filter will be introduced. Then, a
dimensioning procedure for all its components will be explained in
detail, such as the input filter, the current and voltage controllers.
This active power filter is simulated using OrCAD program showing
the validity of the theoretical study.
Abstract: This paper describes the design and fabrication of a clock and data recovery circuit (CDR). We propose a new clock and data recovery which is based on a 1/4-rate frequency detector (QRFD). The proposed frequency detector helps reduce the VCO frequency and is thus advantageous for high speed application. The proposed frequency detector can achieve low jitter operation and extend the pull-in range without using the reference clock. The proposed CDR was implemented using a 1/4-rate bang-bang type phase detector (PD) and a ring voltage controlled oscillator (VCO). The CDR circuit has been fabricated in a standard 0.18 CMOS technology. It occupies an active area of 1 x 1 and consumes 90 mW from a single 1.8V supply.
Abstract: The continued interest in the use of distributed generation in recent years is leading to the growth in number of distributed generators connected to distribution networks. Steady state voltage rise resulting from the connection of these generators can be a major obstacle to their connection at lower voltage levels. The present electric distribution network is designed to keep the customer voltage within tolerance limit. This may require a reduction in connectable generation capacity, under utilization of appropriate generation sites. Thus distribution network operators need a proper voltage regulation method to allow the significant integration of distributed generation systems to existing network. In this work a voltage rise problem in a typical distribution system has been studied. A method for voltage regulation of distribution system with multiple DG system by coordinated operation distributed generator, capacitor and OLTC has been developed. A sensitivity based analysis has been carried out to determine the priority for individual generators in multiple DG environment. The effectiveness of the developed method has been evaluated under various cases through simulation results.
Abstract: The designing of charge pump with high gain Op-
Amp is a challenging task for getting faithful response .Design of
high performance phase locked loop require ,a design of high
performance charge pump .We have designed a operational amplifier
for reducing the error caused by high speed glitch in a transistor and
mismatch currents . A separate Op-Amp has designed in 180 nm
CMOS technology by CADENCE VIRTUOSO tool. This paper
describes the design of high performance charge pump for GHz
CMOS PLL targeting orthogonal frequency division multiplexing
(OFDM) application. A high speed low power consumption Op-Amp
with more than 500 MHz bandwidth has designed for increasing the
speed of charge pump in Phase locked loop.
Abstract: Selective harmonic elimination-pulse width modulation techniques offer a tight control of the harmonic spectrum of a given voltage waveform generated by a power electronic converter along with a low number of switching transitions. Traditional optimization methods suffer from various drawbacks, such as prolonged and tedious computational steps and convergence to local optima; thus, the more the number of harmonics to be eliminated, the larger the computational complexity and time. This paper presents a novel method for output voltage harmonic elimination and voltage control of PWM AC/AC voltage converters using the principle of hybrid Real-Coded Genetic Algorithm-Pattern Search (RGA-PS) method. RGA is the primary optimizer exploiting its global search capabilities, PS is then employed to fine tune the best solution provided by RGA in each evolution. The proposed method enables linear control of the fundamental component of the output voltage and complete elimination of its harmonic contents up to a specified order. Theoretical studies have been carried out to show the effectiveness and robustness of the proposed method of selective harmonic elimination. Theoretical results are validated through simulation studies using PSIM software package.
Abstract: This paper aims to present the reviews of the
application of neural network in shunt active power filter (SAPF).
From the review, three out of four components of SAPF structure,
which are harmonic detection component, compensating current
control, and DC bus voltage control, have been adopted some of
neural network architecture as part of its component or even
substitution. The objectives of most papers in using neural network in
SAPF are to increase the efficiency, stability, accuracy, robustness,
tracking ability of the systems of each component. Moreover,
minimizing unneeded signal due to the distortion is the ultimate goal
in applying neural network to the SAPF. The most famous
architecture of neural network in SAPF applications are ADALINE
and Backpropagation (BP).
Abstract: In this paper, investigation of subsynchronous
resonance (SSR) characteristics of a hybrid series compensated
system and the design of voltage controller for three level 24-pulse
Voltage Source Converter based Static Synchronous Series
Compensator (SSSC) is presented. Hybrid compensation consists of
series fixed capacitor and SSSC which is a active series FACTS
controller. The design of voltage controller for SSSC is based on
damping torque analysis, and Genetic Algorithm (GA) is adopted for
tuning the controller parameters. The SSR Characteristics of SSSC
with constant reactive voltage control modes has been investigated.
The results show that the constant reactive voltage control of SSSC
has the effect of reducing the electrical resonance frequency, which
detunes the SSR.The analysis of SSR with SSSC is carried out based
on frequency domain method, eigenvalue analysis and transient
simulation. While the eigenvalue and damping torque analysis are
based on D-Q model of SSSC, the transient simulation considers both
D-Q and detailed three phase nonlinear system model using
switching functions.
Abstract: This paper discusses coordinated reactive power -
voltage (Q-V) control in a multi machine steam power plant. The
drawbacks of manual Q-V control are briefly listed, and the design
requirements for coordinated Q-V controller are specified.
Theoretical background and mathematical model of the new
controller are presented next followed by validation of developed
Matlab/Simulink model through comparison with recorded
responses in real steam power plant and description of practical
realisation of the controller. Finally, the performance of
commissioned controller is illustrated on several examples of
coordinated Q-V control in real steam power plant and compared
with manual control.
Abstract: An efficient architecture for low jitter All Digital
Phase Locked Loop (ADPLL) suitable for high speed SoC
applications is presented in this paper. The ADPLL is designed using
standard cells and described by Hardware Description Language
(HDL). The ADPLL implemented in a 90 nm CMOS process can
operate from 10 to 200 MHz and achieve worst case frequency
acquisition in 14 reference clock cycles. The simulation result shows
that PLL has cycle to cycle jitter of 164 ps and period jitter of 100 ps
at 100MHz. Since the digitally controlled oscillator (DCO) can
achieve both high resolution and wide frequency range, it can meet
the demands of system-level integration. The proposed ADPLL can
easily be ported to different processes in a short time. Thus, it can
reduce the design time and design complexity of the ADPLL, making
it very suitable for System-on-Chip (SoC) applications.
Abstract: This paper presents a novel control strategy of a threephase
four-wire Unified Power Quality (UPQC) for an improvement
in power quality. The UPQC is realized by integration of series and
shunt active power filters (APFs) sharing a common dc bus capacitor.
The shunt APF is realized using a thee-phase, four leg voltage source
inverter (VSI) and the series APF is realized using a three-phase,
three leg VSI. A control technique based on unit vector template
technique (UTT) is used to get the reference signals for series APF,
while instantaneous sequence component theory (ISCT) is used for
the control of Shunt APF. The performance of the implemented
control algorithm is evaluated in terms of power-factor correction,
load balancing, neutral source current mitigation and mitigation of
voltage and current harmonics, voltage sag and swell in a three-phase
four-wire distribution system for different combination of linear and
non-linear loads. In this proposed control scheme of UPQC, the
current/voltage control is applied over the fundamental supply
currents/voltages instead of fast changing APFs currents/voltages,
there by reducing the computational delay and the required sensors.
MATLAB/Simulink based simulations are obtained, which support
the functionality of the UPQC. MATLAB/Simulink based
simulations are obtained, which support the functionality of the
UPQC.