Abstract: In this paper is reported an analysis about the outdoor air pollution of the urban centre of the city of Messina. The variations of the most critical pollutants concentrations (PM10, O3, CO, C6H6) and their trends respect of climatic parameters and vehicular traffic have been studied. Linear regressions have been effectuated for representing the relations among the pollutants; the differences between pollutants concentrations on weekend/weekday were also analyzed. In order to evaluate air pollution and its effects on human health, a method for calculating a pollution index was implemented and applied in the urban centre of the city. This index is based on the weighted mean of the most detrimental air pollutants concentrations respect of their limit values for protection of human health. The analyzed data of the polluting substances were collected by the Assessorship of the Environment of the Regional Province of Messina in the year 2004. A statistical analysis of the air quality index trends is also reported.
Abstract: This study applied the Gaussian trajectory
transfer-coefficient model (GTx) to simulate the particulate matter
concentrations and the source apportionments at Nanzih Air Quality
Monitoring Station in southern Taiwan from November 2007 to
February 2008. The correlation coefficient between the observed and
the calculated daily PM10 concentrations is 0.5 and the absolute bias of
the PM10 concentrations is 24%. The simulated PM10 concentrations
matched well with the observed data. Although the emission rate of
PM10 was dominated by area sources (58%), the results of source
apportionments indicated that the primary sources for PM10 at Nanzih
Station were point sources (42%), area sources (20%) and then upwind
boundary concentration (14%). The obvious difference of PM10 source
apportionment between episode and non-episode days was upwind
boundary concentrations which contributed to 20% and 11% PM10
sources, respectively. The gas-particle conversion of secondary
aerosol and long range transport played crucial roles on the PM10
contribution to a receptor.
Abstract: The main objective of this research is to synthesize silk fibroin fiber for indoor air particulate removal. Silk cocoons were de-gummed using 0.5 wt % Na2CO3 alkaline solutions at 90 Ó╣ìC for 60 mins, washed with distilled water, and dried at 80 Ó╣ìC for 3 hrs in a vacuum oven. Two sets of experiment were conducted to investigate the impacts of initial particulate matter (PM) concentration and that of air flow rate on the removal efficiency. Rice bran collected from a local rice mill in Ubonratchathani province was used as indoor air contaminant in this work. The morphology and physical properties of silk fibroin (SF) fiber were measured. The SEM revealed the deposition of PM on the used fiber. The PM removal efficiencies of 72.29 ± 3.03 % and 39.33 ± 1.99 % were obtained of PM10 and PM2.5, respectively, when using the initial PM concentration at 0.040 mg/m3 and 0.020 mg/m3 of PM10 and PM2.5, respectively, with the air flow rate of 5 L/min.
Abstract: Particulate matter (PM) in ambient air is responsible
for adverse health effects in adults and children. Relatively little is
known about the concentrations, sources and health effects of PM in
indoor air. A monitoring study was conducted in Ankara by three
campaigns in order to measure PM levels in indoor and outdoor
environments to identify and quantify associations between sources
and concentrations. Approximately 82 homes (1st campaign for 42,
2nd campaign for 12, and 3rd campaign for 28), three rooms (living
room, baby-s room and living room used as a baby-s room) and
outdoor ambient at each home were sampled with Grimm
Environmental Dust Monitoring (EDM) 107, during different
seasonal periods of 2011 and 2012. In this study, the relationship
between indoor and outdoor PM levels for particulate matter less than
10 micrometer (.m) (PM10), particulate matter less than 2.5.m
(PM2.5) and particulate matter less than 1.0.m (PM1) were
investigated. The mean concentration of PM10, PM2.5, and PM1.0 at
living room used as baby-s room is higher than living and baby-s
room (or bedroom) for three sampling campaigns. It is concluded that
the household activities and environmental conditions are very
important for PM concentrations in the indoor environments during
the sampling periods. The amount of smokers, being near a main
street and/or construction activities increased the PM concentration.
This study is based on the assessment the relationship between indoor
and outdoor PM levels and the household activities and
environmental conditions
Abstract: A simultaneous study on indoor and outdoor particulate matter concentrations was done in five elementary schools in central parts of Tehran, Iran. Three sizes of particles including PM10, PM2.5 and PM1.0 were measured in 13 classrooms within this schools during winter (January, February and March) 2009. A laserbased portable aerosol spectrometer Model Grimm-1.108, was used for the continuous measurement of particles. The average indoor concentration of PM10, PM2.5 and PM1.0 in studied schools were 274 μg/m3, 42 μg/m3 and 19 μg/m3 respectively; and average outdoor concentrations of PM10, PM2.5 and PM1.0 were evaluated to be 22 μg/m3, 38 μg/m3 and 140 μg/m3 respectively.
Abstract: The forest fires in Thailand are annual occurrence which is the cause of air pollutions. This study intended to estimate the emission from forest fire during 2005-2009 using MODerateresolution Imaging Spectro-radiometer (MODIS) sensor aboard the Terra and Aqua satellites, experimental data, and statistical data. The forest fire emission is estimated using equation established by Seiler and Crutzen in 1982. The spatial and temporal variation of forest fire emission is analyzed and displayed in the form of grid density map. From the satellite data analysis suggested between 2005 and 2009, the number of fire hotspots occurred 86,877 fire hotspots with a significant highest (more than 80% of fire hotspots) in the deciduous forest. The peak period of the forest fire is in January to May. The estimation on the emissions from forest fires during 2005 to 2009 indicated that the amount of CO, CO2, CH4, and N2O was about 3,133,845 tons, 47,610.337 tons, 204,905 tons, and 6,027 tons, respectively, or about 6,171,264 tons of CO2eq. They also emitted 256,132 tons of PM10. The year 2007 was found to be the year when the emissions were the largest. Annually, March is the period that has the maximum amount of forest fire emissions. The areas with high density of forest fire emission were the forests situated in the northern, the western, and the upper northeastern parts of the country.
Abstract: Several studies have shown the association between
ambient particulate matter (PM) and adverse health effects and
climate change, thus highlighting the need to limit the anthropogenic
sources of PM. PM Exposure is commonly monitored as mass
concentration of PM10 (particle aerodynamic diameter < 10μm) or
PM2.5 (particle aerodynamic diameter < 2.5μm), although increasing
toxicity with decreasing aerodynamic diameter has been reported due
to increased surface area and enhanced chemical reactivity with other
species. Additionally, the light scattering properties of PM increases
with decreasing size. Hence, it is important to study the chemical
characterization of finer fraction of the particulate matter and to
identify their sources so that they can be controlled appropriately to a
large extent at the sources before reaching to the receptors.
Abstract: Coarse and fine particulate matter were collected at a
residential area at Vashi, Navi Mumbai and the filter samples were
analysed for trace elements using PIXE technique. The trend of
particulate matter showed higher concentrations during winter than
the summer and monsoon concentration levels. High concentrations
of elements related to soil and sea salt were found in PM10 and
PM2.5. Also high levels of zinc and sulphur found in the particulates
of both the size fractions. EF analysis showed enrichment of Cu, Cr
and Mn only in the fine fraction suggesting their origin from
anthropogenic sources. The EF value was observed to be maximum
for As, Pb and Zn in the fine particulates. However, crustal derived
elements showed very low EF values indicating their origin from
soil. The PCA based multivariate studies identified soil, sea salt,
combustion and Se sources as common sources for coarse and
additionally an industrial source has also been identified for fine
particles.
Abstract: In July 2012, an indoor/outdoor monitoring
programme was undertaken in two university sports facilities: a
fronton and a gymnasium. Comfort parameters (temperature, relative
humidity, CO and CO2) and total volatile organic compounds
(VOCs) were continuously monitored. Concentrations of NO2,
carbonyl compounds and individual VOCs were obtained. Low
volume samplers were used to collect particulate matter (PM10). The
minimum ventilation rates stipulated for acceptable indoor air quality
were observed in both sports facilities. It was found that cleaning
activities may have a large influence on the VOC levels. Acrolein
was one of the most abundant carbonyl compounds, showing
concentrations above the recommended limit. Formaldehyde was
detected at levels lower than those commonly reported for other
indoor environments. The PM10 concentrations obtained during the
occupancy periods ranged between 38 and 43μgm-3 in the fronton and
from 154 to 198μgm-3 in the gymnasium.