Abstract: Catalytic oxidation of benzene assisted by ozone, on alumina, silica, and boehmite-supported Ni/Pd catalysts was investigated at 353 K to assess the influence of the support on the reaction. Three bimetallic Ni/Pd nanosized samples with loading 4.7% of Ni and 0.17% of Pd supported on SiO2, AlOOH and Al2O3 were synthesized by the extractive-pyrolytic method. The phase composition was characterized by means of XRD and the surface area and pore size were estimated using Brunauer–Emmett–Teller (BET) and Barrett–Joyner–Halenda (BJH) methods. At the beginning of the reaction, catalysts were significantly deactivated due to the accumulation of intermediates on the catalyst surface and after 60 minutes it turned stable. Ni/Pd/AlOOH catalyst showed the highest steady-state activity in comparison with the Ni/Pd/SiO2 and Ni/Pd/Al2O3 catalysts. Their activity depends on the ozone decomposition potential of the catalysts because of generating oxidizing active species. The sample with the highest ozone decomposition ability which correlated to the surface area of the support oxidizes benzene to the highest extent.
Abstract: In recent research copper and manganese systems
were found to be the most active in CO and organic compounds
oxidation among the base catalysts. The mixed copper manganese
oxide has been widely studied in oxidation reactions because of their
higher activity at low temperatures in comparison with single oxide
catalysts. The results showed that the formation of spinel
CuxMn3−xO4 in the oxidized catalyst is responsible for the activity
even at room temperature. That is why the most of the investigations
are focused on the hopcalite catalyst (CuMn2O4) as the best coppermanganese
catalyst. Now it’s known that this is true only for CO
oxidation, but not for mixture of CO and VOCs. The purpose of this
study is to investigate the alumina supported copper-manganese
catalysts with different Cu/Mn molar ratio in terms of oxidation of
CO, methanol and dimethyl ether. The catalysts were prepared by impregnation of γ-Al2O3 with
copper and manganese nitrates and the catalytic activity
measurements were carried out in two stage continuous flow
equipment with an adiabatic reactor for simultaneous oxidation of all
compounds under the conditions closest possible to the industrial. Gas
mixtures on the input and output of the reactor were analyzed with a
gas chromatograph, equipped with FID and TCD detectors. The
texture characteristics were determined by low-temperature (- 196oС)
nitrogen adsorption in a Quantachrome Instruments NOVA 1200e
(USA) specific surface area & pore analyzer. Thermal, XRD and
TPR analyses were performed. It was established that the active component of the mixed Cu-
Mn/γ–alumina catalysts strongly depends on the Cu/Mn molar ratio.
Highly active alumina supported Cu-Mn catalysts for CO, methanol
and DME oxidation were synthesized. While the hopcalite is the best
catalyst for CO oxidation, the best compromise for simultaneous
oxidation of all components is the catalyst with Cu/Mn molar ratio
1:5.
Abstract: Pt/γ-Al2O3 membrane catalysts were prepared via an
evaporative-crystallization deposition method. The obtained Pt/γ-
Al2O3 catalyst activity was tested after characterization (SEM-EDAX
observation, BET measurement, permeability assessment) in the
catalytic oxidation of selected volatile organic compound (VOC) i.e.
propane, fed in mixture of oxygen. The VOC conversion (nearly
90%) obtained by varying the operating temperature showed that
flow-through membrane reactor might do better in the abatement of
VOCs.
Abstract: This work proposes an optical fiber system (OF) for
sensing various volatile organic compounds (VOCs) in human breath
for the diagnosis of some metabolic disorders as a non-invasive
methodology. The analyzed VOCs are alkanes (i.e., ethane, pentane,
heptane, octane, and decane), and aromatic compounds (i.e., benzene,
toluene, and styrene). The OF displays high analytical performance
since it provides near real-time responses, rapid analysis, and low
instrumentation costs, as well as it exhibits useful linear range and
detection limits; the developed OF sensor is also comparable to a
reference methodology (gas chromatography-mass spectrometry) for
the eight tested VOCs.
Abstract: In July 2012, an indoor/outdoor monitoring
programme was undertaken in two university sports facilities: a
fronton and a gymnasium. Comfort parameters (temperature, relative
humidity, CO and CO2) and total volatile organic compounds
(VOCs) were continuously monitored. Concentrations of NO2,
carbonyl compounds and individual VOCs were obtained. Low
volume samplers were used to collect particulate matter (PM10). The
minimum ventilation rates stipulated for acceptable indoor air quality
were observed in both sports facilities. It was found that cleaning
activities may have a large influence on the VOC levels. Acrolein
was one of the most abundant carbonyl compounds, showing
concentrations above the recommended limit. Formaldehyde was
detected at levels lower than those commonly reported for other
indoor environments. The PM10 concentrations obtained during the
occupancy periods ranged between 38 and 43μgm-3 in the fronton and
from 154 to 198μgm-3 in the gymnasium.