The Analysis of TRACE/PARCS in the Simulation of Ultimate Response Guideline for Lungmen ABWR

In this research, the TRACE/PARCS model of  Lungmen ABWR has been developed for verification of ultimate  response guideline (URG) efficiency. This ultimate measure was  named as DIVing plan, abbreviated from system depressurization,  water injection and containment venting. The simulation initial  condition is 100% rated power/100% rated core flow. This research  focuses on the estimation of the time when the fuel might be damaged  with no water injection by using TRACE/PARCS first. Then, the  effect of the reactor core isolation system (RCIC), control  depressurization and ac-independent water addition system (ACIWA),  which can provide the injection with 950 gpm are also estimated for  the station blackout (SBO) transient.  

The Analysis of TRACE/FRAPTRAN in the Fuel Rods of Maanshan PWR for LBLOCA

Fuel rod analysis program transient (FRAPTRAN)  code was used to study the fuel rod performance during a postulated  large break loss of coolant accident (LBLOCA) in Maanshan nuclear  power plant (NPP). Previous transient results from thermal hydraulic  code, TRACE, with the same LBLOCA scenario, were used as input  boundary conditions for FRAPTRAN. The simulation results showed  that the peak cladding temperatures and the fuel centerline  temperatures were all below the 10CFR50.46 LOCA criteria. In  addition, the maximum hoop stress was 18 MPa and the oxide  thickness was 0.003mm for the present simulation cases, which are all  within the safety operation ranges. The present study confirms that this  analysis method, the FRAPTRAN code combined with TRACE, is an  appropriate approach to predict the fuel integrity under LBLOCA with  operational ECCS.  

Modification and Characterization of Bacterial Cellulose Biopolymer as Proton Conducting Membrane

This study describes the preparation of a novel proton conducting membranes based on bacterial cellulose (BC) modified by grafting of 2-acrylamido-2-methyl-1 -propanesulfonic acid (AMPS) through UV-induced graft polymerization. These AMPS-g-BC membranes have been characterized by various techniques including FTIR, SEM and TGA, to find their successful grafting of AMPS on BC, surface morphology and thermal stability, respectively. Physical properties of AMPS-g-BC membranes have been assessed in terms of Lamda value( λ ), ion exchange capacity(IEC) and proton conductivity. The relationship between degree of grafting and AMPS concentration used for grafting has been determined by weight gain method. An optimum proton conductivity equal to 2.89x10-2 S cm-1 and IEC value equal to 1.79 mmol g-1 have been obtained when 20 wt% AMPS concentration is used for grafting (i.e. the corresponding membrane is notated as AMPS20-g-BC).