Abstract: Reverse osmosis (RO) membranes have been widely used for desalination to purify water for drinking and other purposes. Although at present most RO membranes have no resistance to chlorine, chlorine-resistant membranes are being developed. Therefore, direct chlorine treatment or chlorine washing will be an option in preventing biofouling on chlorine-resistant membranes. Furthermore, if particle accumulation control is possible by using chlorine washing, expensive pretreatment for particle removal can be removed or simplified. The objective of this study was to determine the effective hypochlorite washing condition required for controlling biofilm formation and inorganic particle accumulation on RO membrane in a continuous flow channel with RO membrane and spacer. In this study, direct chlorine washing was done by soaking fouled RO membranes in hypochlorite solution and fluorescence intensity was used to quantify biofilm on the membrane surface. After 48 h of soaking the membranes in high fouling potential waters, the fluorescence intensity decreased to 0 from 470 using the following washing conditions: 10 mg/L chlorine concentration, 2 times/d washing interval, and 30 min washing time. The chlorine concentration required to control biofilm formation decreased as the chlorine concentration (0.5–10 mg/L), the washing interval (1–4 times/d), or the washing time (1–30 min) increased. For the sample solutions used in the study, 10 mg/L chlorine concentration with 2 times/d interval, and 5 min washing time was required for biofilm control. The optimum chlorine washing conditions obtained from soaking experiments proved to be applicable also in controlling biofilm formation in continuous flow experiments. Moreover, chlorine washing employed in controlling biofilm with suspended particles resulted in lower amounts of organic (0.03 mg/cm2) and inorganic (0.14 mg/cm2) deposits on the membrane than that for sample water without chlorine washing (0.14 mg/cm2 and 0.33 mg/cm2, respectively). The amount of biofilm formed was 79% controlled by continuous washing with 10 mg/L of free chlorine concentration, and the inorganic accumulation amount decreased by 58% to levels similar to that of pure water with kaolin (0.17 mg/cm2) as feed water. These results confirmed the acceleration of particle accumulation due to biofilm formation, and that the inhibition of biofilm growth can almost completely reduce further particle accumulation. In addition, effective hypochlorite washing condition which can control both biofilm formation and particle accumulation could be achieved.
Abstract: The paper presents a simulation study of the electrical
characteristic of Bulk Planar Junctionless Transistor (BPJLT) using
spacer. The BPJLT is a transistor without any PN junctions in the
vertical direction. It is a gate controlled variable resistor. The
characteristics of BPJLT are analyzed by varying the oxide material
under the gate. It can be shown from the simulation that an ideal
subthreshold slope of ~60 mV/decade can be achieved by using highk
dielectric. The effects of variation of spacer length and material on
the electrical characteristic of BPJLT are also investigated in the
paper. The ION / IOFF ratio improvement is of the order of 107 and the
OFF current reduction of 10-4 is obtained by using gate dielectric of
HfO2 instead of SiO2.
Abstract: This paper presents the experimental results of high-density polyethylene cable spacers for 22 kV distribution systems under salt water dip wheel test based on IEC 62217. The strength of anti-tracking and anti-erosion of cable spacer surface was studied in this study. During the test, dry band arc and corona discharge were observed on cable spacer surface. After 30,000 cycles of salt water dip wheel test, obviously surface erosion and tracking were observed especially on the ground end. Chemical analysis results by fourier transforms infrared spectroscopy showed chemical changed from oxidation and carbonization reaction on tested cable spacer. Increasing of C=O and C=C bonds confirmed occurrence of these reactions.
Abstract: Polystyrene (PS) was extracted from Styrofoam (expanded polystyrene foam) waste, so called white pollutant. The PS was functionalized with N,N- Bis(2-aminobenzylidene)benzene-1,2-diamine (ABA) ligand through an azo spacer. The resin was characterized by FT-IR spectroscopy and elemental analysis. The PS-N=N-ABA resin was used for the enrichment and speciation of Cr(III)/Cr(VI) ions and total Cr determination in aqueous samples by flame atomic absorption spectrometry (FAAS). The separation of Cr(III)/Cr(VI) ions was achieved at pH 2. The recovery of Cr(VI) ions was achieved ≥ 95.0% at optimum parameters: pH 2; resin amount 300mg; flow rates 2.0mL min-1 of solution and 2.0mL min-1 of eluent (2.0mol L-1 HNO3). Total Cr was determined by oxidation of Cr(III) to Cr(VI) ions using H2O2. The limit of detection (LOD) and quantification (LOQ) of Cr(VI) were found to be 0.40 and 1.20μg L-1, respectively with preconcentration factor of 250. Total saturation and breakthrough capacitates of the resin for Cr(IV) ions were found to be 0.181 and 0.531mmol g-1, respectively. The proposed method was successfully applied for the preconcentration/speciation of Cr(III)/Cr(VI) ions and determination of total Cr in industrial effluents.
Abstract: It is well known that metallic particles reduce the
reliability of Gas-Insulated Substation (GIS) equipments by initiating
partial discharge (PDs) that can lead to breakdown and complete
failure of GIS. This paper investigates the characteristics of PDs
caused by metallic particle adhering to the solid spacer. The PD
detection and measurement were carried out by using IEC 60270
method with particles of different sizes and at different positions on
the spacer surface. The results show that a particle of certain size at
certain position possesses a unique PD characteristic as compared to
those caused by particles of different sizes and/or at different
positions. Therefore PD characteristics may be useful for the particle
size and position identification.
Abstract: This paper looks into detailed investigation of
thermal-hydraulic characteristics of the flow field in a fuel rod
model, especially near the spacer. The area investigate represents a
source of information on the velocity flow field, vortex, and on the
amount of heat transfer into the coolant all of which are critical for
the design and improvement of the fuel rod in nuclear power plants.
The flow field investigation uses three-dimensional Computational
Fluid Dynamics (CFD) with the Reynolds stresses turbulence model
(RSM). The fuel rod model incorporates a vertical annular channel
where three different shapes of spacers are used; each spacer shape is
addressed individually. These spacers are mutually compared in
consideration of heat transfer capabilities between the coolant and
the fuel rod model. The results are complemented with the calculated
heat transfer coefficient in the location of the spacer and along the
stainless-steel pipe.
Abstract: A new chelating resin is prepared by coupling
Amberlite XAD-4 with 1-amino-2-naphthole through an azo spacer.
The resulting sorbent has been characterized by FT-IR, elemental
analysis and thermogravimetric analysis (TGA) and studied for
preconcentrating of Cu (II) using flame atomic absorption
spectrometry (FAAS) for metal monitoring. The optimum pH value
for sorption of the copper ions was 6.5. The resin was subjected to
evaluation through batch binding of mentioned metal ion.
Quantitative desorption occurs instantaneously with 0.5 M HNO3.
The sorption capacity was found 4.8 mmol.g-1 of resin for Cu (II) in
the aqueous solution. The chelating resin can be reused for 10 cycles
of sorption-desorption without any significant change in sorption
capacity. A recovery of 99% was obtained the metal ions with 0.5 M
HNO3 as eluting agent. The method was applied for metal ions
determination from industrial waste water sample.
Abstract: A new chelating resin is prepared by coupling Amberlite XAD-4 with 1-amino-2-naphthole through an azo spacer. The resulting sorbent has been characterized by FT-IR, elemental analysis and thermogravimetric analysis (TGA) and studied for preconcentrating of Fe (II) using flame atomic absorption spectrometry (FAAS) for metal monitoring. The optimum pH value for sorption of the iron ions was 6.5. The resin was subjected to evaluation through batch binding of mentioned metal ion. Quantitative desorption occurs instantaneously with 0.5 M HNO3. The sorption capacity was found 4.1 mmol.g-1 of resin for Fe (II) in the aqueous solution. The chelating resin can be reused for 10 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 97% was obtained the metal ions with 0.5 M HNO3 as eluting agent. The method was applied for metal ions determination from industrial waste water sample.