Abstract: In this paper, a Dynamic Economic Dispatch (DED) model is developed for the system consisting of both thermal generators and wind turbines. The inclusion of a significant amount of wind energy into power systems has resulted in additional constraints on DED to accommodate the intermittent nature of the output. The probability of stochastic wind power based on the Weibull probability density function is included in the model as a constraint; A Here-and-Now Approach. The Environmental Protection Agency-s hourly emission target, which gives the maximum emission during the day, is used as a constraint to reduce the atmospheric pollution. A 69-bus test system with non-smooth cost function is used to illustrate the effectiveness of the proposed model compared with static economic dispatch model with including the wind power.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. The methods can be used
to assess the transmission prices, but also to recover the transmission
fixed cost. In this paper is presented the influence of the modification of
commons structure has on the specific price of transfer. The operator
must make use of a few basic principles about allocation. Most
tracing methods are based on the proportional sharing principle. In this
paper Kirschen method is used. In order to illustrate this method, the 25-
bus test system is used, elaborated within the Electrical Power
Engineering Department, from Timisoara, Romania.
Abstract: Ferroresonance is an electrical phenomenon in
nonlinear character, which frequently occurs in power system due to
transmission line faults and single or more-phase switching on the
lines as well as usage of the saturable transformers. In this study, the
ferroresonance phenomena are investigated under the modeling of the
West Anatolian Electric Power Network of 380 kV in Turkey. The
ferroresonance event is observed as a result of removing the loads at
the end of the lines. In this sense, two different cases are considered.
At first, the switching is applied at 2nd second and the ferroresonance
affects are observed between 2nd and 4th seconds in the voltage
variations of the phase-R. Hence the ferroresonance and nonferroresonance
parts of the overall data are compared with each
others using the Fourier transform techniques to show the
ferroresonance affects.
Abstract: The paper presents new results of a recent industry
supported research and development study in which an efficient
framework for evaluating practical and meaningful power system
reliability and quality indices was applied. The system-wide
integrated performance indices are capable of addressing and
revealing areas of deficiencies and bottlenecks as well as
redundancies in the composite generation-transmission-demand
structure of large-scale power grids. The technique utilizes a linear
programming formulation, which simulates practical operating
actions and offers a general and comprehensive framework to assess
the harmony and compatibility of generation, transmission and
demand in a power system. Practical applications to a reduced
system model as well as a portion of the Saudi power grid are also
presented in the paper for demonstration purposes.
Abstract: This paper presents a systematic approach for designing Unified Power Flow Controller (UPFC) based supplementary damping controllers for damping low frequency oscillations in a single-machine infinite-bus power system. Detailed investigations have been carried out considering the four alternatives UPFC based damping controller namely modulating index of series inverter (mB), modulating index of shunt inverter (mE), phase angle of series inverter (δB ) and phase angle of the shunt inverter (δE ). The design problem of the proposed controllers is formulated as an optimization problem and Real- Coded Genetic Algorithm (RCGA) is employed to optimize damping controller parameters. Simulation results are presented and compared with a conventional method of tuning the damping controller parameters to show the effectiveness and robustness of the proposed design approach.
Abstract: This paper presents an approach for the design of
fuzzy logic power system stabilizers using genetic algorithms. In the
proposed fuzzy expert system, speed deviation and its derivative
have been selected as fuzzy inputs. In this approach the parameters of
the fuzzy logic controllers have been tuned using genetic algorithm.
Incorporation of GA in the design of fuzzy logic power system
stabilizer will add an intelligent dimension to the stabilizer and
significantly reduces computational time in the design process. It is
shown in this paper that the system dynamic performance can be
improved significantly by incorporating a genetic-based searching
mechanism. To demonstrate the robustness of the genetic based
fuzzy logic power system stabilizer (GFLPSS), simulation studies on
multimachine system subjected to small perturbation and three-phase
fault have been carried out. Simulation results show the superiority
and robustness of GA based power system stabilizer as compare to
conventionally tuned controller to enhance system dynamic
performance over a wide range of operating conditions.
Abstract: An effort to develop a unit commitment approach
capable of handling large power systems consisting of both thermal
and hydro generating units offers a large profitable return. In order to
be feasible, the method to be developed must be flexible, efficient
and reliable. In this paper, various proposed methods have been
described along with their strengths and weaknesses. As all of these
methods have some sort of weaknesses, a comprehensive algorithm
that combines the strengths of different methods and overcomes each
other-s weaknesses would be a suitable approach for solving
industry-grade unit commitment problem.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: Electricity market activities and a growing demand for electricity have led to heavily stressed power systems. This requires operation of the networks closer to their stability limits. Power system operation is affected by stability related problems, leading to unpredictable system behavior. Voltage stability refers to the ability of a power system to sustain appropriate voltage levels through large and small disturbances. Steady-state voltage stability is concerned with limits on the existence of steady-state operating points for the network. FACTS devices can be utilized to increase the transmission capacity, the stability margin and dynamic behavior or serve to ensure improved power quality. Their main capabilities are reactive power compensation, voltage control and power flow control. Among the FACTS controllers, Static Var Compensator (SVC) provides fast acting dynamic reactive compensation for voltage support during contingency events. In this paper, voltage stability assessment with appropriate representations of tap-changer transformers and SVC is investigated. Integrating both of these devices is the main topic of this paper. Effect of the presence of tap-changing transformers on static VAR compensator controller parameters and ratings necessary to stabilize load voltages at certain values are highlighted. The interrelation between transformer off nominal tap ratios and the SVC controller gains and droop slopes and the SVC rating are found. P-V curves are constructed to calculate loadability margins.
Abstract: Power systems and transformer are intrinsic apparatus, therefore its reliability and safe operation is important to determine their operation conditions, and the industry uses quality control tests in the insulation design of oil filled transformers. Hence the service period effect on AC dielectric strength is significant. The effect of aging on transformer oil physical, chemical and electrical properties was studied using the international testing methods for the evaluation of transformer oil quality. The study was carried out on six transformers operate in the field and for monitoring periods over twenty years. The properties which are strongly time dependent were specified and those which have a great impact on the transformer oil acidity, breakdown voltage and dissolved gas analysis were defined. Several tests on the transformers oil were studied to know the time of purifying or changing it, moreover prediction of the characteristics of it under different operation conditions.
Abstract: This paper presents a practical scheme that can be used for allocating the transmission loss to generators and loads. In this scheme first the share of a generator or load on the current through a branch is determined using Z-bus modified matrix. Then the current components are decomposed and the branch loss allocation is obtained. A motivation of proposed scheme is to improve the results of Z-bus method and to reach more fair allocation. The proposed scheme has been implemented and tested on several networks. To achieve practical and applicable results, the proposed scheme is simulated and compared on the transmission network (400kv) of Khorasan region in Iran and the 14-bus standard IEEE network. The results show that the proposed scheme is comprehensive and fair to allocating the energy losses of a power market to its participants.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. These methods can be
used to assess the transmission prices, but also to recover the
transmission fixed cost. In this paper is presented the influence of the
modification of commons structure has on the specific price of transfer
and on active power losses. The authors propose a power losses
allocation method, based on Kirschen-s method. The system operator
must make use of a few basic principles about allocation. The only
necessary information is the power flows on system branches and the
modifications applied to power system buses. In order to illustrate this
method, the 25-bus test system is used, elaborated within the Electrical
Power Engineering Department, from Timisoara, Romania.
Abstract: A renewable energy system discussed in this paper is
a stand-alone wind-hydrogen system for a remote island in Australia.
The analysis of an existing wind-diesel power system was performed.
Simulation technique was used to model the power system currently
employed on the island, and simulated different configurations of
additional hydrogen energy system. This study aims to determine the
suitable hydrogen integrated configuration to setting up the prototype
system for the island, which helps to reduce the diesel consumption
on the island. A set of configurations for the hydrogen system and
associated parameters that consists of wind turbines, electrolysers,
hydrogen internal combustion engines, and storage tanks has been
purposed. The simulation analyses various configurations that
perfectly balances the system to meet the demand on the island.
Abstract: We design and discuss metal-dielectric antireflection coating on metallic substrates for Solar Selective Absorbers of Concentrating Solar Power Systems. The average reflectance is 8.5% at 400-3000nm and 84.4% at 3000nm-10000nm of the metal-dielectric structure.
Abstract: This paper presents a procedure of forming the
mathematical model of radial electric power systems for simulation
of both transient and steady-state conditions. The research idea has
been based on nodal voltages technique and on differentiation of
Kirchhoff's current law (KCL) applied to each non-reference node of
the radial system, the result of which the nodal voltages has been
calculated by solving a system of algebraic equations. Currents of the
electric power system components have been determined by solving
their respective differential equations. Transforming the three-phase
coordinate system into Cartesian coordinate system in the model
decreased the overall number of equations by one third. The use of
Cartesian coordinate system does not ignore the DC component
during transient conditions, but restricts the model's implementation
for symmetrical modes of operation only. An example of the input
data for a four-bus radial electric power system has been calculated.
Abstract: This paper presents the solution of power economic dispatch (PED) problem of generating units with valve point effects and multiple fuel options using Self-Adaptive Differential Evolution (SDE) algorithm. The global optimal solution by mathematical approaches becomes difficult for the realistic PED problem in power systems. The Differential Evolution (DE) algorithm is found to be a powerful evolutionary algorithm for global optimization in many real problems. In this paper the key parameters of control in DE algorithm such as the crossover constant CR and weight applied to random differential F are self-adapted. The PED problem formulation takes into consideration of nonsmooth fuel cost function due to valve point effects and multi fuel options of generator. The proposed approach has been examined and tested with the numerical results of PED problems with thirteen-generation units including valve-point effects, ten-generation units with multiple fuel options neglecting valve-point effects and ten-generation units including valve-point effects and multiple fuel options. The test results are promising and show the effectiveness of proposed approach for solving PED problems.
Abstract: To determine the presence and location of faults in a transmission by the adaptation of protective distance relay based on the measurement of fixed settings as line impedance is achieved by several different techniques. Moreover, a fast, accurate and robust technique for real-time purposes is required for the modern power systems. The appliance of radial basis function neural network in transmission line protection is demonstrated in this paper. The method applies the power system via voltage and current signals to learn the hidden relationship presented in the input patterns. It is experiential that the proposed technique is competent to identify the particular fault direction more speedily. System simulations studied show that the proposed approach is able to distinguish the direction of a fault on a transmission line swiftly and correctly, therefore suitable for the real-time purposes.
Abstract: Battery storage system is emerging as an essential component of hybrid power system based on renewable energy resources such as solar and wind in order to make these sources dispatchable. Accurate modeling of battery storage system is ssential in order to ensure optimal planning of hybrid power systems incorporating battery storage. Majority of the system planning studies involving battery storage assume battery charging efficiency to be constant. However a strong correlation exists between battery charging efficiency and battery state of charge. In this work a Fuzzy logic based model has been presented for determining battery charging efficiency relative to a particular SOC. In order to demonstrate the efficacy of proposed approach, reliability evaluation studies are carried out for a hypothetical autonomous hybrid power system located in Jaisalmer, Rajasthan, India. The impact of considering battery charging efficiency as a function of state of charge is compared against the assumption of fixed battery charging efficiency for three different configurations comprising of wind-storage, solar-storage and wind-solar-storage.
Abstract: Based on the component approach, three kinds of
dynamic load models, including a single –motor model, a two-motor
model and composite load model have been developed for the
stability studies of Khuzestan power system. The study results are
presented in this paper. Voltage instability is a dynamic phenomenon
and therefore requires dynamic representation of the power system
components. Industrial loads contain a large fraction of induction
machines. Several models of different complexity are available for
the description investigations. This study evaluates the dynamic
performances of several dynamic load models in combination with
the dynamics of a load changing transformer. Case study is steel
industrial substation in Khuzestan power systems.
Abstract: The global chaos synchronization for a class of time-delayed power systems is investigated via observer-based approach. By employing the concepts of quadratic stability theory and generalized system model, a new sufficient criterion for constructing an observer is deduced. In contrast to the previous works, this paper proposes a theoretical and systematic design procedure to realize chaos synchronization for master-slave power systems. Finally, an illustrative example is given to show the applicability of the obtained scheme.